Feature and Intensity Based Medical Image Registration Using Particle Swarm Optimization

Image registration is an important aspect in medical image analysis, and kinds use in a variety of medical applications. Examples include diagnosis, pre/post surgery guidance, comparing/merging/integrating images from multi-modal like Magnetic Resonance Imaging (MRI), and Computed Tomography (CT). Whether registering images across modalities for a single patient or registering across patients for a single modality, registration is an effective way to combine information from different images into a normalized frame for reference. Registered datasets can be used for providing information relating to the structure, function, and pathology of the organ or individual being imaged. In this paper a hybrid approach for medical images registration has been developed. It employs a modified Mutual Information (MI) as a similarity metric and Particle Swarm Optimization (PSO) method. Computation of mutual information is modified using a weighted linear combination of image intensity and image gradient vector flow (GVF) intensity. In this manner, statistical as well as spatial image information is included into the image registration process. Maximization of the modified mutual information is effected using the versatile Particle Swarm Optimization which is developed easily with adjusted less parameter. The developed approach has been tested and verified successfully on a number of medical image data sets that include images with missing parts, noise contamination, and/or of different modalities (CT, MRI). The registration results indicate the proposed model as accurate and effective, and show the posture contribution in inclusion of both statistical and spatial image data to the developed approach.

[1]  V.R.S Mani,et al.  Survey of Medical Image Registration , 2013 .

[2]  Albert C. S. Chung,et al.  Robust Optimization Using Disturbance for Image Registration , 2006, WBIR.

[3]  Hany Farid,et al.  Medical image registration with partial data , 2006, Medical Image Anal..

[4]  Yuhui Shi,et al.  Particle swarm optimization: developments, applications and resources , 2001, Proceedings of the 2001 Congress on Evolutionary Computation (IEEE Cat. No.01TH8546).

[5]  D. Hill,et al.  Non-rigid image registration: theory and practice. , 2004, The British journal of radiology.

[6]  Lei Huang,et al.  Feature-based image registration using the shape context , 2010 .

[7]  Josien P. W. Pluim,et al.  Evaluation of Optimization Methods for Nonrigid Medical Image Registration Using Mutual Information and B-Splines , 2007, IEEE Transactions on Image Processing.

[8]  G. Bartoli Image Registration Techniques: A Comprehensive Survey , 2007 .

[9]  Brian Birge,et al.  PSOt - a particle swarm optimization toolbox for use with Matlab , 2003, Proceedings of the 2003 IEEE Swarm Intelligence Symposium. SIS'03 (Cat. No.03EX706).

[10]  Huan Wang,et al.  New cubic reference table based image steganography , 2018, Multimedia Tools and Applications.

[11]  Jan Flusser,et al.  Image registration methods: a survey , 2003, Image Vis. Comput..

[12]  Paul A. Viola,et al.  Alignment by Maximization of Mutual Information , 1997, International Journal of Computer Vision.

[13]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.

[14]  Transformation Functions for Image Registration Image Fusion Systems Research ag , 2003 .

[15]  Giancarlo Mauri,et al.  Multimodal medical image registration using Particle Swarm Optimization: A review , 2016, 2016 IEEE Symposium Series on Computational Intelligence (SSCI).

[16]  Ahmad Ayatollahi,et al.  A new hybrid particle swarm optimization for multimodal brain image registration , 2012 .

[17]  Genlin Ji,et al.  Preliminary research on abnormal brain detection by wavelet-energy and quantum- behaved PSO. , 2016, Technology and health care : official journal of the European Society for Engineering and Medicine.

[18]  R. Suganya,et al.  INTENSITY BASED IMAGE REGISTRATION BY MAXIMIZATION OF MUTUAL INFORMATION , 2010 .

[19]  Paul Suetens,et al.  A Viscous Fluid Model for Multimodal Non-rigid Image Registration Using Mutual Information , 2002, MICCAI.

[20]  Junaed Sattar Snakes , Shapes and Gradient Vector Flow , 2022 .

[21]  D. Hill,et al.  Medical image registration , 2001, Physics in medicine and biology.

[22]  Nicholas Ayache,et al.  The Correlation Ratio as a New Similarity Measure for Multimodal Image Registration , 1998, MICCAI.

[23]  Yen-Wei Chen,et al.  Hybrid Particle Swarm Optimization for Medical Image Registration , 2009, 2009 Fifth International Conference on Natural Computation.

[24]  H. K. Abhyankar,et al.  Image Registration Techniques: An overview , 2009 .

[25]  Yudong Zhang,et al.  A Comprehensive Survey on Particle Swarm Optimization Algorithm and Its Applications , 2015 .

[26]  Max A. Viergever,et al.  Mutual-information-based registration of medical images: a survey , 2003, IEEE Transactions on Medical Imaging.

[27]  Jian Shen,et al.  Medical image classification based on multi-scale non-negative sparse coding , 2017, Artif. Intell. Medicine.

[28]  Noppadol Chumchob,et al.  International Journal of C 2009 Institute for Scientific Numerical Analysis and Modeling Computing and Information a Robust Affine Image Registration Method , 2022 .

[29]  Andries Petrus Engelbrecht,et al.  A Cooperative approach to particle swarm optimization , 2004, IEEE Transactions on Evolutionary Computation.

[30]  J. N. Ulysses Measuring Similarity in Medical Registration , 2010 .

[31]  Jerry L. Prince,et al.  Gradient vector flow deformable models , 2000 .

[32]  Yudong Zhang,et al.  Magnetic resonance brain classification by a novel binary particle swarm optimization with mutation and time-varying acceleration coefficients , 2016, Biomedizinische Technik. Biomedical engineering.

[33]  Aura Conci The 17th International Conference on Systems, Signals and Image Processing (IWSSIP) , 2011, Integr. Comput. Aided Eng..