A novel current sensor for home energy use monitoring

Summary form only given. This paper presents a novel magnetic sensor array based technique for measuring currents in a group of enclosed conductors. It is designed specifically for monitoring the real-time power consumptions of North American homes. The technique consists of three key components: magnetic field sensors deployed in close proximity of the power conductors to be measured; algorithms to compute the conductor currents based on the magnetic fields measured; a simple, integrated sensor calibration and communication scheme. Prototype devices have been developed based on the technique. Extensive lab and field tests have demonstrated that the technique can provide adequate current measurements for residential homes. Combining with the non-intrusive load monitoring methods, the proposed measurement technique represents an attractive platform to create a complete home energy use tracking system.

[1]  Luca di Rienzo,et al.  Circular arrays of magnetic sensors for current measurement , 2001, IEEE Trans. Instrum. Meas..

[2]  Paul Wallich Parsing power [Resources_Hand On] , 2013, IEEE Spectrum.

[3]  T Joseph Lui,et al.  Get Smart , 2010, IEEE Power and Energy Magazine.

[4]  E.R. Olson,et al.  Effective Use of Miniature, Multi-Point, Field-Based Current Sensors without Magnetic Cores , 2007, 2007 IEEE Industry Applications Annual Meeting.

[5]  G. W. Hart,et al.  Nonintrusive appliance load monitoring , 1992, Proc. IEEE.

[6]  A. EMANUEL,et al.  A Non-Contact Technique for Determining Harmonic Currents Present in Individual Conductors of Overhead Lines , 1983, IEEE Transactions on Power Apparatus and Systems.

[7]  Walmir Freitas,et al.  An Event Window Based Load Monitoring Technique for Smart Meters , 2012, IEEE Transactions on Smart Grid.

[8]  Steven B. Leeb,et al.  Power signature analysis , 2003 .

[9]  Michael Zeifman,et al.  Nonintrusive appliance load monitoring: Review and outlook , 2011, IEEE Transactions on Consumer Electronics.

[10]  F. Sultanem,et al.  Using appliance signatures for monitoring residential loads at meter panel level , 1991 .

[11]  Gabriele D'Antona,et al.  Processing magnetic sensor array data for AC current measurement in multiconductor systems , 2001, IEEE Trans. Instrum. Meas..

[12]  Sioe Mak,et al.  TWACS, A New Viable Two-Way Automatic Communication System for Distribution Networks. Part I: Outbound Communication , 1982, IEEE Transactions on Power Apparatus and Systems.