Planar micro sensors for in vivo myocardial pH measurements.

Potentiometric responses of microelectronically fabricated planar pH sensors based on both TDDA or ETH 5294 proton neutral carriers, in aminated PVC matrix, were evaluated with respect to main analytical parameters (linear ranges, slopes, reproducibility of potential measurements, potential drift and membrane resistance). In order to increase the electrode life time, increased amounts of membrane material were applied on the Ag/AgCl-poly-HEMA active spots of the polyimide substrate. The electrodes were implanted into an in situ porcine beating heart preparation at a midmyocardial depth in order to monitor H(+) concentration changes during the course of coronary artery occlusion.

[1]  R. Buck,et al.  The potentiometric pH response of chromoionophores used in optical sensors , 1993 .

[2]  M. Meyerhoff,et al.  Response properties of ion-selective polymeric membrane electrodes prepared with aminated and carboxylated poly(vinyl chloride). , 1988, Analytical chemistry.

[3]  R. Yuan,et al.  Poly(vinyl chloride) matrix membrane pH electrode based on 4,4′-bis[(N,N-dialkylamino)methyl]azobenzene with a wide linear pH response range , 1992 .

[4]  R. B. Ash,et al.  In vivo and in vitro testing of microelectronically fabricated planar sensors designed for applications in cardiology , 1993 .

[5]  W. Simon,et al.  Neutral carrier based hydrogen ion selective microelectrode for extra- and intracellular studies. , 1981, Analytical chemistry.

[6]  W. E. Morf,et al.  Membrane technology and dynamic response of ion-selective liquid-membrane electrodes , 1991 .

[7]  G. Widdowson Electrode Technology in Clinical Chemistry Today and Tomorrow , 1988 .

[8]  S. Pogwizd,et al.  Mechanisms underlying the development of ventricular fibrillation during early myocardial ischemia. , 1990, Circulation research.

[9]  W. Simon,et al.  Ion-selective membrane electrodes for clinical use. , 1986, Clinical chemistry.

[10]  H. L. Wu,et al.  A PVC membrane pH-sensitive electrode based on methyldioctadecylamine as neutral carrier. , 1987, Talanta.

[11]  R P Kusy,et al.  Responses of H(+) selective solvent polymeric membrane electrodes fabricated from modified PVC membranes. , 1993, Talanta.

[12]  R. Kusy,et al.  Design of ionophore-free H+-selective solvent polymeric membranes for further biomedical applications , 1993 .

[13]  M. Janse,et al.  Electrophysiological mechanisms of ventricular arrhythmias resulting from myocardial ischemia and infarction. , 1989, Physiological reviews.

[14]  H. Troy Nagle,et al.  Flexible (Kapton-based) microsensor arrays of high stability for cardiovascular applications , 1993 .

[15]  I. Watanabe,et al.  Effect of graded coronary flow reduction on ionic, electrical, and mechanical indexes of ischemia in the pig. , 1987, Circulation.

[16]  R. Buck,et al.  New neutral carrier-based H+ selective membrane electrodes , 1992 .

[17]  W. E. Morf,et al.  Theoretical treatment of the dynamic response of ion-selective membrane electrodes , 1975 .

[18]  E. Pretsch,et al.  Design of neutral hydrogen ion carriers for solvent polymeric membrane electrodes of selected pH range , 1986 .

[19]  E. Pretsch,et al.  Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral carriers , 1985 .

[20]  P. Schulthess,et al.  A hydrogen ion-selective liquid-membrane electrode based on tri-n-dodecylamine as neutral carrier , 1981 .

[21]  P B Corr,et al.  Reentrant and Nonreentrant Mechanisms Contribute to Arrhythmogenesis During Early Myocardial Ischemia: Results Using Three‐Dimensional Mapping , 1987, Circulation research.

[22]  R. Buck,et al.  Anion effects on Donnan failure of aminated-poly(vinyl chloride)-based and neutral-carrier-based pH sensors , 1993 .

[23]  W. Simon,et al.  Lifetime of neutral carrier based ion-selective liquid-membrane electrodes , 1980 .

[24]  M. Meyerhoff New in vitro analytical approaches for clinical chemistry measurements in critical care. , 1990, Clinical chemistry.

[25]  J. Biernat,et al.  Application of azoles as neutral carriers in liquid membrane ion-selective pH electrodes , 1990 .

[26]  V. Egorov,et al.  H(+)-selective electrodes based on neutral carriers: Specific features in behaviour and quantitative description of the electrode response. , 1990, Talanta.