Evaluation of the SenseWear Mini Armband to assess energy expenditure during pole walking.

The current study aimed to show the validity of a portable motion sensor, the SenseWear Armband (SWA), for the estimation of energy expenditure during pole walking. Twenty healthy adults (mean ± SD: age 30.1 ± 7.2 year, body mass 66.1 ± 10.6 kg, height 172.4 ± 8.0 cm, BMI 22.1 ± 2.4 kg · m(-2)) wore the armband during randomized pole walking activities at a constant speed (1.25 m · s(-1)) and at seven grades (0%, ± 5%, ± 15% and ± 25%). Estimates of total energy expenditure from the armband were compared with values derived from indirect calorimetry methodology (IC) using a 2-way mixed model ANOVA (Device × Slope), correlation analyses and Bland-Altman plots. Results revealed significant main effects for device, and slope (p < .025) as well as a significant interaction (p < .001). Significant differences between IC and SWA were observed for all conditions (p < .05). SWA generally underestimate the EE values during uphill PW by 0.04 kcal · kg(-1) · min(-1) (p < .05). Whereas, a significant overestimation has been detected during flat and downhill PW by 0.01 and 0.03 kcal · kg(-1) · min(-1) (p < .05), respectively. The Bland-Altman plots revealed bias of the armband compared with the indirect calorimetry at any condition examined. The present data suggest that the armband is not accurate to correctly detect and estimate the energy expenditure during pole walking activities. Therefore, the observed over- and under-estimations warrants more work to improve the ability of SWA to accurately measure EE for these activities.

[1]  A. Utter,et al.  Validity of COSMED's Quark CPET Mixing Chamber System in Evaluating Energy Metabolism During Aerobic Exercise in Healthy Male Adults , 2013, Research in sports medicine.

[2]  Ning Wang,et al.  Energy expenditure estimation during normal ambulation using triaxial accelerometry and barometric pressure , 2012, Physiological measurement.

[3]  W. Brown,et al.  The effects of pole walking on health in adults: A systematic review , 2012, Scandinavian journal of medicine & science in sports.

[4]  R. Shephard,et al.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective , 2012, European Journal of Applied Physiology.

[5]  J. Aaboe,et al.  Is it possible to reduce the knee joint compression force during level walking with hiking poles? , 2011, Scandinavian journal of medicine & science in sports.

[6]  D. Mignault,et al.  Accuracy of the SenseWear Armband™ during Ergocycling , 2011, International journal of sports medicine.

[7]  Nigel H. Lovell,et al.  Can Triaxial Accelerometry Accurately Recognize Inclined Walking Terrains? , 2010, IEEE Transactions on Biomedical Engineering.

[8]  A. Belli,et al.  Effects of hiking pole inertia on energy and muscular costs during uphill walking. , 2008, Medicine and science in sports and exercise.

[9]  Charlie Potter,et al.  Comparison of activity monitors to estimate energy cost of treadmill exercise. , 2004, Medicine and science in sports and exercise.

[10]  M. Marcus,et al.  Evaluation of the SenseWear Pro Armband to assess energy expenditure during exercise. , 2004, Medicine and science in sports and exercise.

[11]  K. Campbell,et al.  Field evaluation of energy expenditure in women using Tritrac accelerometers. , 2002, Medicine and science in sports and exercise.

[12]  T. Church,et al.  Field Testing of Physiological Responses Associated with Nordic Walking , 2002, Research quarterly for exercise and sport.

[13]  K Aminian,et al.  Can accelerometry accurately predict the energy cost of uphill/downhill walking? , 2001, Ergonomics.

[14]  S. Blair,et al.  A comparative evaluation of three accelerometry-based physical activity monitors. , 2000, Medicine and science in sports and exercise.

[15]  David R. Bassett Validity and Reliability issues in Objective Monitoring of Physical Activity , 2000, Research quarterly for exercise and sport.

[16]  J. Porcari,et al.  The physiological responses to walking with and without Power Poles on treadmill exercise. , 1997, Research quarterly for exercise and sport.

[17]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[18]  D A Schoeller,et al.  Measurement of energy expenditure in humans by doubly labeled water method. , 1982, Journal of applied physiology: respiratory, environmental and exercise physiology.

[19]  H. S. Wolff,et al.  The integrating motor pneumotachograph: a new instrument for the measurement of energy expenditure by indirect calorimetry. , 1958, Quarterly journal of experimental physiology and cognate medical sciences.

[20]  M. Misigoj-Durakovic,et al.  Validation of the Sensewear Armband during recreational in-line skating , 2011, European Journal of Applied Physiology.