Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks.

This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0.05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27.57 +/- 5.06 microm) than other groups (I: 11.19 +/- 2.54 microm, III: 12.88 +/- 2.93 microm, IV: 13.77 +/- 1.51 microm) (P < 0.05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58.66 +/- 14.30 microm) was significantly different from cp Ti group after diagonal section (IV: 27.51 +/- 8.28 microm) (P < 0.05). On the tightened side, no significant differences were found between groups (P > 0.05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

[1]  J D Preston,et al.  Preceramic and postceramic solder joints. , 1975, The Journal of prosthetic dentistry.

[2]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[3]  G. Murray,et al.  Design of superstructures for osseointegrated fixtures. , 1985, Swedish dental journal. Supplement.

[4]  T. Jemt Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. , 1992, The International journal of oral & maxillofacial implants.

[5]  K. Böning,et al.  Studies on laser- and plasma-welded titanium. , 1993, Dental materials : official publication of the Academy of Dental Materials.

[6]  Amos Gilat,et al.  Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit. , 1995 .

[7]  J. Powers,et al.  Accuracy of wax, autopolymerized, and light-polymerized resin pattern materials. , 1996, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[8]  A. Carr,et al.  Comparison of strains transferred to a bone simulant between as-cast and postsoldered implant frameworks for a five-implant-supported fixed prosthesis. , 1996, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[9]  H. Alkumru,et al.  Distortion of metal-ceramic fixed partial dentures resulting from metal-conditioning firing. , 1996, Quintessence international.

[10]  T Jemt,et al.  Prosthesis misfit and marginal bone loss in edentulous implant patients. , 1996, The International journal of oral & maxillofacial implants.

[11]  J. Sutherland,et al.  Marginal discrepancy of ceramic crowns with redesigned implant components. , 1996, The Journal of prosthetic dentistry.

[12]  E. Richter,et al.  Microbial leakage and marginal fit of the implant-abutment interface. , 1997, The International journal of oral & maxillofacial implants.

[13]  B R Lang,et al.  Fit of implant frameworks fabricated by different techniques. , 1997, The Journal of prosthetic dentistry.

[14]  T. Dérand,et al.  Description and evaluation of a simplified method to achieve passive fit between cast titanium frameworks and implants. , 1998, The International journal of oral & maxillofacial implants.

[15]  R. Wang,et al.  Thermal modeling of laser welding for titanium dental restorations. , 1998, The Journal of prosthetic dentistry.

[16]  G. Rübeling New techniques in spark erosion: the solution to an accurately fitting screw-retained implant restoration. , 1999, Quintessence international.

[17]  A. Carr,et al.  Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings. , 1999, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[18]  T. Jemt,et al.  Clinical experiences of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw: a 5-year follow-up study. , 1999, Clinical implant dentistry and related research.

[19]  S. Oruç,et al.  Fit of titanium and a base metal alloy metal-ceramic crown. , 2000, The Journal of prosthetic dentistry.

[20]  L Albingre,et al.  Prosthodontics: The laser welding technique applied to the non precious dental alloys procedure and results , 2001, British Dental Journal.

[21]  M. Çehreli,et al.  The Significance Of Passive Framework Fit In Implant Prosthodontics: Current Status , 2001, Implant dentistry.

[22]  Lourenço Correr Sobrinho,et al.  Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings. , 2003, Dental materials : official publication of the Academy of Dental Materials.

[23]  Steven E Eckert,et al.  Cyclic loading of implant-supported prostheses: changes in component fit over time. , 2003, The Journal of prosthetic dentistry.

[24]  C. Francischone,et al.  In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion. , 2004, The Journal of prosthetic dentistry.

[25]  U. Koke,et al.  In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures. , 2004, Journal of oral rehabilitation.

[26]  R. Tiossi,et al.  Comparative analysis of the fit of 3-unit implant-supported frameworks cast in nickel-chromium and cobalt-chromium alloys and commercially pure titanium after casting, laser welding, and simulated porcelain firings. , 2008, The International journal of prosthodontics.

[27]  S A de Sousa,et al.  Passive fit of frameworks in titanium and palladium-silver alloy submitted the laser welding. , 2008, Journal of oral rehabilitation.

[28]  R. Tiossi,et al.  An alternative section method for casting and posterior laser welding of metallic frameworks for an implant-supported prosthesis. , 2009, Journal of prosthodontics : official journal of the American College of Prosthodontists.