Transfer of Near-Infrared Calibration Model for Determining Fiber Content in Flax: Effects of Transfer Samples and Standardization Procedure

The transfer of a calibration model for determining fiber content in flax stem was accomplished between two near-infrared spectrometers, which are the same brand but which require a standardization. In this paper, three factors, including transfer sample set, spectral type, and standardization method, were investigated to obtain the best standardization result. Twelve standardization files were produced from two sets of the transfer sample (sealed reference standards and a subset of the prediction set), two types of the transfer sample spectra (raw and preprocessed spectra), and three standardization methods (direct standardization (DS), piecewise direct standardization (PDS), and double window piecewise direct standardization (DWPDS)). The efficacy of the model transfer was evaluated based on the root mean square error of prediction, calculated using the independent prediction samples. Results indicated that the standardization using the sealed reference standards was unacceptable, but the standardization using the prediction subset was adequate. The use of the preprocessed spectra of the transfer samples led to the calibration transfers that were successful, especially for the PDS and the DWPDS correction. Finally, standardization using the prediction subset and their preprocessed spectra with DWPDS correction proved to be the best method for transferring the model.

[1]  I. J. Wesley,et al.  Optical Matching of near Infrared Reflectance Monochromator Instruments for the Analysis of Ground and Whole Wheat , 1999 .

[2]  T. Fearn Standardisation and Calibration Transfer for near Infrared Instruments: A Review , 2001 .

[3]  B. Kowalski,et al.  Improvement of multivariate calibration through instrument standardization , 1992 .

[4]  Paul Geladi,et al.  Calibration Transfer for Predicting Lake-Water pH from near Infrared Spectra of Lake Sediments , 1999 .

[5]  Luiz E.P. Borges,et al.  Evaluation of Standardisation Methods of near Infrared Calibration Models , 2002 .

[6]  Franklin E. Barton,et al.  A New Approach for Estimating Purity of Processed Flax Fibre by NIR Spectroscopy , 2004 .

[7]  D. Himmelsbach,et al.  A Comparative Study of Fourier Transform Raman and NIR Spectroscopic Methods for Assessment of Protein and Apparent Amylose in Rice , 2004 .

[8]  C. Spiegelman,et al.  Calibration Transfer between PDA-Based NIR Spectrometers in the NIR Assessment of Melon Soluble Solids Content , 2001 .

[9]  B. Kowalski,et al.  Multivariate instrument standardization , 1991 .

[10]  Steven D. Brown,et al.  Standardization of Fiber-Optic Probes for Near-Infrared Multivariate Calibrations , 1998 .

[11]  D. Massart,et al.  Standardization of near-infrared spectrometric instruments , 1996 .

[12]  Bruce R. Kowalski,et al.  Additive Background Correction in Multivariate Instrument Standardization , 1995 .

[13]  F. E. Barton,et al.  Application of Partial Least-Squares Regression to Near-Infrared Reflectance Spectroscopic Determination of Shive Content in Flax , 2003, Applied spectroscopy.

[14]  Franklin E. Barton,et al.  Prediction of Shive Content in Pilot Plant Processed Flax by near Infrared Reflectance Spectroscopy , 2004 .

[15]  D. Himmelsbach,et al.  Partial Least Squares Regression Calibration for Determining Wax Content in Processed Flax Fiber by Near-Infrared Spectroscopy , 2006, Applied spectroscopy.

[16]  K. Walsh,et al.  Calibration Transfer between Miniature Photodiode Array-Based Spectrometers in the near Infrared Assessment of Mandarin Soluble Solids Content , 2002 .

[17]  Onno E. de Noord,et al.  Multivariate calibration standardization , 1994 .

[18]  H. Swierenga,et al.  Comparison of Two Different Approaches toward Model Transferability in NIR Spectroscopy , 1998 .

[19]  F. E. Barton,et al.  Analysis of fiber content in flax stems by near-infrared spectroscopy. , 2002, Journal of agricultural and food chemistry.

[20]  Charles R. Hurburgh,et al.  The Standardisation of near Infrared Instruments Using Master Selection and Wiener Filter Methods , 2001 .

[21]  Desire L. Massart,et al.  Modified Algorithm for Standardization of Near-Infrared Spectrometric Instruments , 1995 .

[22]  Pierre Dardenne Calibration Transfer in near Infrared Spectroscopy , 2002 .