Median Sternotomy or Right Thoracotomy Techniques for Total Artificial Heart Implantation in Calves.

The choice of optimal operative access technique for mechanical circulatory support device implantation ensures successful postoperative outcomes. In this study, we retrospectively evaluated the median sternotomy and lateral thoracotomy incisions for placement of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) in a bovine model. The CFTAH was implanted in 17 calves (Jersey calves; weight range, 77.0-93.9 kg) through a median sternotomy (n = 9) or right thoracotomy (n = 8) for elective chronic implantation periods of 14, 30, or 90 days. Similar preoperative preparation, surgical techniques, and postoperative care were employed. Implantation of the CFTAH was successfully performed in all cases. Both methods provided excellent surgical field visualization. After device connection, however, the median sternotomy approach provided better visualization of the anastomoses and surgical lines for hemostasis confirmation and repair due to easier device displacement, which is severely limited following right thoracotomy. All four animals sacrificed after completion of the planned durations (up to 90 days) were operated through full median sternotomy. Our data demonstrate that both approaches provide excellent initial field visualization. Full median sternotomy provides larger viewing angles at the anastomotic suture line after device connection to inflow and outflow ports.

[1]  Nicole A Byram,et al.  First report of 90-day support of 2 calves with a continuous-flow total artificial heart. , 2015, The Journal of thoracic and cardiovascular surgery.

[2]  K. Fukamachi,et al.  Double-Wire Sternal Closure Technique in Bovine Animal Models for Total Artificial Heart Implant , 2015, The International journal of artificial organs.

[3]  A. Carpentier,et al.  Animal studies with the Carmat bioprosthetic total artificial heart. , 2015, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[4]  W. Cohn,et al.  Eight-Year Experience with a Continuous-Flow Total Artificial Heart in Calves , 2014, ASAIO journal.

[5]  W. Cohn,et al.  Ninety-Day Survival of a Calf Implanted with a Continuous-Flow Total Artificial Heart , 2014, ASAIO journal.

[6]  D. Olsen,et al.  Implantation of the total artificial heart by lateral thoracotomy. , 2008, Artificial organs.

[7]  Jae Seung Shin,et al.  Ventricular Assist Device Implantation Using a Right Thoracotomy , 2006, ASAIO journal.

[8]  Daniel Tamez,et al.  Biventricular Support with the Jarvik 2000 Axial Flow Pump: A Feasibility Study , 2003, ASAIO journal.

[9]  Mitsuo Umezu,et al.  EVAHEART: an implantable centrifugal blood pump for long-term circulatory support. , 2002, The Japanese journal of thoracic and cardiovascular surgery : official publication of the Japanese Association for Thoracic Surgery = Nihon Kyobu Geka Gakkai zasshi.

[10]  R. Dowling,et al.  Initial Experience with the AbioCor Implantable Replacement Heart at the University of Louisville , 2000, ASAIO journal.

[11]  BARTLEY P. GRIFFITH,et al.  Long Term Animal Experiments With an Intraventricular Axial Flow Blood Pump , 1997, ASAIO journal.

[12]  J F Antaki,et al.  Survival for Up to Six Months in Calves Supported With an Implantable Axial Flow Ventricular Assist Device , 1997, ASAIO journal.

[13]  J M Fuqua,et al.  In vivo evaluation of an intraventricular electric axial flow pump for left ventricular assistance. , 1994, ASAIO journal.

[14]  W. Cohn,et al.  Continuous-flow total artificial heart supports long-term survival of a calf. , 2009, Texas Heart Institute journal.

[15]  L. V. von Segesser,et al.  Performance of a new implantable cardiac assist centrifugal pump. , 2001, Artificial organs.

[16]  J. Pacholewicz,et al.  Perioperative management of calves undergoing implantation of a left ventricular assist device. , 2000, Veterinary surgery : VS.