Effect of geometrical parameters on heat transfer and pressure drop characteristics of plate fin and tube heat exchangers

Abstract In this study, the influences of the changes in fin geometry on heat transfer and pressure drop of a plate fin and tube heat exchanger are investigated, numerically. A computational fluid dynamics (CFD) program called Fluent is used in the analysis. The segment of one tenth of fin is used in the modeling, due to symmetrical condition. The results of heat transfer, static, and total pressure drop values of ten different fins are tabulated and the normalized values of them are, also, given for the comparison of the models. The distance between fins is found to have a considerable effect on pressure drop. It is observed that placing the fin tube at downstream region affects heat transfer positively. Another important result of the study is that increasing ellipticity of the fin tube increases the heat transfer while it, also, results in an important reduction in pressure drop.

[1]  Franz J. Schulenberg,et al.  Finned Elliptical Tubes and Their Application in Air-Cooled Heat Exchangers , 1966 .

[2]  Hitoshi Asano,et al.  Flow and Heat Transfer Performance of a Plate-Fin and Tube Heat Exchanger (1st report: Effect of fin pitch) , 1994 .

[3]  Chi-Chuan Wang,et al.  Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part II: Correlation , 2000 .

[4]  Ricardo Romero-Méndez,et al.  Effect of fin spacing on convection in a plate fin and tube heat exchanger , 2000 .

[5]  F. Saboya,et al.  Experiments on elliptic sections in one- and two-row arrangements of plate fin and tube heat exchangers , 2001 .

[6]  Ephraim M Sparrow,et al.  Experiments on a Three-Row Fin and Tube Heat Exchanger , 1976 .

[7]  Chi-Chuan Wang,et al.  Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part I: new experimental data , 2000 .

[8]  Ralph L. Webb,et al.  Air-Side Heat Transfer in Finned Tube Heat Exchangers , 1980 .

[9]  Ephraim M Sparrow,et al.  Local and average transfer coefficients for one-row plate fin and tube heat exchanger configurations , 1974 .

[10]  R. A. Johns,et al.  Performance characteristics correlation for round tube and plate finned heat exchangers , 1998 .

[11]  Luiz Alberto Oliveira Rocha,et al.  A comparative study of elliptical and circular sections in one- and two-row tubes and plate fin heat exchangers , 1997 .

[12]  Sadik Kakaç,et al.  Convective Heat Transfer , 1995 .

[13]  F. Saboya,et al.  Performance of one- and two-row tube and plate fin heat exchangers , 1984 .

[14]  P. Das,et al.  Optimum dimensions of plate fins for fin-tube heat exchangers , 1997 .

[15]  Ephraim M Sparrow,et al.  Transfer characteristics of two-row plate fin and tube heat exchanger configurations , 1976 .

[16]  Tae-Ho Song,et al.  Microscopic phenomena and macroscopic evaluation of heat transfer from plate fins/circular tube assembly using naphthalene sublimation technique , 2002 .