Corrosion Resistance and Biocompatibility of Passivated NiTi

Equiatomic nickel-titanium (NiTi) or Nitinol possess a unique combination of properties, including superelasticity and shape memory, which are very attractive for biomedical applications. NiTi has been used in orthopedic and orthodontic implants for several decades and has contributed to significant improvements in these fields [1, 2]. This alloy is rapidly becoming the material of choice for selfexpanding stents, graft support systems, filters, baskets and various other devices for minimally invasive interventional procedures (Fig. 1) [1,3]. While the superior performance of NiTi over conventional engineering materials for implants is well documented [1,4,5], the high nickel content of the alloy (55 weight % Ni) and itspossible influence on biocompatibility continues to be an issue of concern. This concern is further complicated by the conflicting literature on corrosion resistance.

[1]  M. Anke,et al.  Nickel--an essential element. , 1984, IARC scientific publications.

[2]  L. Yahia,et al.  Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents. , 1999, Journal of biomedical materials research.

[3]  G. Cisneros,et al.  Nickel hypersensitivity in the orthodontic patient. , 1993, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[4]  T. W. Duerig,et al.  Oxidation of an NiTi alloy , 1990 .

[5]  M. Beatty,et al.  Nickel release from orthodontic arch wires and cellular immune response to various nickel concentrations. , 1999, Journal of biomedical materials research.

[6]  Shibi Lu Medical Applications of Ni-Ti Alloys in China , 1990 .

[7]  A. Gonzalez-Elipe,et al.  Oxidation and diffusion processes in nickel-titanium oxide systems , 1993 .

[8]  S. Bishara,et al.  Biodegradation of orthodontic appliances. Part II. Changes in the blood level of nickel. , 1993, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[9]  J. Haasters The Use of Ni-Ti as an Implant Material in Orthopedics , 1990 .

[10]  T W Duerig,et al.  The utility of superelasticity in medicine. , 1996, Bio-medical materials and engineering.

[11]  R Venugopalan Corrosion testing of stents: a novel fixture to hold entire device in deployed form and finish. , 1999, Journal of biomedical materials research.

[12]  T. Salo,et al.  Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures. , 1997, Journal of biomedical materials research.

[13]  S. Shabalovskaya,et al.  On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys. , 1996, Bio-medical materials and engineering.

[14]  M. Kallioinen,et al.  In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: muscle and perineural tissue responses and encapsule membrane thickness. , 1998, Journal of biomedical materials research.

[15]  B. Kasemo,et al.  Chemical Composition and Morphology of Titanium Surface Oxides , 1985 .

[16]  K. Hayashi,et al.  Evaluation of carcinogenicity and chronic toxicity associated with orthopedic implants in mice. , 1994, Journal of biomedical materials research.

[17]  A G Veldhuizen,et al.  Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy. , 1997, Biomaterials.

[18]  H. Waldron Nickel in the human environment , 1985 .

[19]  T. W. Duerig,et al.  Engineering Aspects of Shape Memory Alloys , 1990 .

[20]  S E Bishara,et al.  Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro. , 1993, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[21]  L. Yahia,et al.  Effect of modification of oxide layer on NiTi stent corrosion resistance. , 1998, Journal of biomedical materials research.

[22]  D. T. Hawkins,et al.  Selected values of the thermodynamic properties of binary alloys , 1973 .

[23]  J. V. van Horn,et al.  Electrochemical and surface characterization of a nickel-titanium alloy. , 1998, Biomaterials.

[24]  K. Speck,et al.  Anodic Polarization Behavior of Ti-Ni and Ti-6A 1-4 V in Simulated Physiological Solutions , 1980, Journal of dental research.

[25]  L. Castleman,et al.  Biocompatibility of nitinol alloy as an implant material. , 1976, Journal of biomedical materials research.

[26]  R. M. Johnson,et al.  Tissue reaction to nitinol wire alloy. , 1973, Oral surgery, oral medicine, and oral pathology.

[27]  Stanley A. Brown,et al.  In vitro studies of fretting corrosion of orthopaedic materials , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[28]  L. Yahia,et al.  In vitro biocompatibility assessment of a nickel-titanium alloy using electron microscopy in situ end-labeling (EM-ISEL). , 1998, Journal of biomedical materials research.