Moving average filtering with deconvolution (MAD) for hidden Markov model with filtering and correlated noise

Ion channel data recorded using the patch clamp technique are low-pass filtered to remove high-frequency noise. Almanjahie et al. (Eur Biophys J 44:545–556, 2015) based statistical analysis of such data on a hidden Markov model (HMM) with a moving average adjustment for the filter but without correlated noise, and used the EM algorithm for parameter estimation. In this paper, we extend their model to include correlated noise, using signal processing methods and deconvolution to pre-whiten the noise. The resulting data can be modelled as a standard HMM and parameter estimates are again obtained using the EM algorithm. We evaluate this approach using simulated data and also apply it to real data obtained from the mechanosensitive channel of large conductance (MscL) in Escherichia coli. Estimates of mean conductances are comparable to literature values. The key advantages of this method are that it is much simpler and computationally considerably more efficient than currently used HMM methods that include filtering and correlated noise.

[1]  L. Baum,et al.  A Maximization Technique Occurring in the Statistical Analysis of Probabilistic Functions of Markov Chains , 1970 .

[2]  Ben Calderhead,et al.  Bayesian Statistical Inference in Ion-Channel Models with Exact Missed Event Correction. , 2016, Biophysical journal.

[3]  D. Rubin,et al.  Maximum likelihood from incomplete data via the EM - algorithm plus discussions on the paper , 1977 .

[4]  Lawrence R. Rabiner,et al.  A tutorial on hidden Markov models and selected applications in speech recognition , 1989, Proc. IEEE.

[5]  K. Magleby,et al.  Kinetic time constants independent of previous single-channel activity suggest Markov gating for a large conductance Ca-activated K channel , 1989, The Journal of general physiology.

[6]  Roman Kuc,et al.  Identification of hidden Markov models for ion channel currents. II. State-dependent excess noise , 1998, IEEE Trans. Signal Process..

[7]  Richard A. Davis,et al.  Time Series: Theory and Methods , 2013 .

[8]  P. Läuger Ionic channels with conformational substates. , 1985, Biophysical journal.

[9]  A G Hawkes,et al.  Relaxation and fluctuations of membrane currents that flow through drug-operated channels , 1977, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[10]  F G Ball,et al.  Markov, fractal, diffusion, and related models of ion channel gating. A comparison with experimental data from two ion channels. , 1989, Biophysical journal.

[11]  Jens Timmer,et al.  On identification of Na+ channel gating schemes using moving-average filtered hidden Markov models , 1999, European Biophysics Journal.

[12]  H. Robert Guy,et al.  The gating mechanism of the large mechanosensitive channel MscL , 2001, Nature.

[13]  Pierre A. Devijver,et al.  Baum's forward-backward algorithm revisited , 1985, Pattern Recognit. Lett..

[14]  H. Künsch,et al.  Statistical Analysis of Ion Channel Data Using Hidden Markov Models With Correlated State-Dependent Noise and Filtering , 2001 .

[15]  P. Läuger Internal motions in proteins and gating kinetics of ionic channels. , 1988, Biophysical journal.

[16]  Boris Martinac,et al.  Bacterial Mechanosensitive Channels as a Paradigm for Mechanosensory Transduction , 2011, Cellular Physiology and Biochemistry.

[17]  H. Sullivan Ionic Channels of Excitable Membranes, 2nd Ed. , 1992, Neurology.

[18]  Roman Kuc,et al.  Identification of hidden Markov models for ion channel currents. I. Colored background noise , 1998, IEEE Trans. Signal Process..

[19]  A. Hawkes,et al.  On the stochastic properties of single ion channels , 1981, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[20]  Boris Martinac,et al.  Hidden Markov analysis of improved bandwidth mechanosensitive ion channel data , 2015, European Biophysics Journal.

[21]  F Sachs,et al.  Hidden Markov modeling for single channel kinetics with filtering and correlated noise. , 2000, Biophysical journal.

[22]  D Colquhoun,et al.  Activation of N‐methyl‐D‐aspartate receptors by L‐glutamate in cells dissociated from adult rat hippocampus. , 1992, The Journal of physiology.

[23]  John G. Proakis,et al.  Digital Signal Processing: Principles, Algorithms, and Applications , 1992 .

[24]  L. Liebovitch Testing fractal and Markov models of ion channel kinetics. , 1989, Biophysical journal.

[25]  R. Milne,et al.  Hidden Markov analysis of mechanosensitive ion channel gating. , 2005, Mathematical biosciences.

[26]  Fred J. Sigworth,et al.  Fitting and Statistical Analysis of Single-Channel Records , 1983 .

[27]  B. Martinac,et al.  Flying-patch patch-clamp study of G22E-MscL mutant under high hydrostatic pressure. , 2011, Biophysical journal.

[28]  John A. Rice,et al.  Fast evaluation of the likelihood of an HMM: ion channel currents with filtering and colored noise , 2001, IEEE Trans. Signal Process..

[29]  Peter G. Gillespie,et al.  Molecular basis of mechanosensory transduction , 2001, Nature.

[30]  R E Oswald,et al.  Rate-amplitude correlation from single-channel records. A hidden structure in ion channel gating kinetics? , 1988, Biophysical journal.

[31]  L. Baum,et al.  An inequality with applications to statistical estimation for probabilistic functions of Markov processes and to a model for ecology , 1967 .

[32]  L S Liebovitch,et al.  Fractal model of ion-channel kinetics. , 1987, Biochimica et biophysica acta.

[33]  S H Chung,et al.  Characterization of single channel currents using digital signal processing techniques based on Hidden Markov Models. , 1990, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.

[34]  John Mourjopoulos,et al.  Digital Equalization of Room Acoustics , 1994 .

[35]  O. Hamill,et al.  Molecular basis of mechanotransduction in living cells. , 2001, Physiological reviews.

[36]  L. Jan Ion Channels—Molecules in Action , 1996, Cell.

[37]  Frederick Sachs,et al.  Energetic and Spatial Parameters for Gating of the Bacterial Large Conductance Mechanosensitive Channel, MscL , 1999, The Journal of general physiology.

[38]  A. S. French,et al.  Fractal and Markov behavior in ion channel kinetics. , 1988, Canadian journal of physiology and pharmacology.

[39]  Richard A. Davis,et al.  Time Series: Theory and Methods (2Nd Edn) , 1993 .

[40]  K L Magleby,et al.  Fractal models are inadequate for the kinetics of four different ion channels. , 1988, Biophysical journal.

[41]  B. Sakmann,et al.  Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches , 1981, Pflügers Archiv.

[42]  Martin Chalfie,et al.  Genetics of sensory mechanotransduction. , 2002, Annual review of genetics.

[43]  R. Keynes The ionic channels in excitable membranes. , 1975, Ciba Foundation symposium.

[44]  X. Z. S. Xu,et al.  Mechanosensitive Channels: In Touch with Piezo , 2010, Current Biology.

[45]  R Horn,et al.  Statistical discrimination of fractal and Markov models of single-channel gating. , 1988, Biophysical journal.

[46]  M. Pellegrino,et al.  Use of conditional distributions in the analysis of ion channel recordings , 2004, European Biophysics Journal.