Extended Time Sampling for Accurate Optical Pulse Reflection Measurement in Level Control
暂无分享,去创建一个
Pulse reflection methods play an important role in the diversified fields of industrial measurement. The paper reports on an optical short-range radar with superior resolution using a modified sampling procedure. The developed system has been tested successfully for level control applications, such as for measuring the meniscus of the molten steel in the mold of a continuous casting installation.
[1] N.S. Nahman,et al. Picosecond-domain waveform measurements , 1978, Proceedings of the IEEE.
[2] Z. Sztankay,et al. Pulsed GaAs laser terrain profiler , 1977, IEEE Journal of Quantum Electronics.
[3] Gunter Kompa. Optical short-range radar for level control measurement , 1984 .