Data Acquisition and Performance Characterization in PET

Positron emission detection systems have developed since their first use in the 1950s to the high-resolution, high-sensitivity tomographic devices that we have today. Configurations differ far more than for a gamma camera, with such variables as the choice of scintillation crystal, 2D or 3D acquisition mode capability, continuous or discrete detectors, full or partial surrounding of the patient, and a variety of transmission scanning arrangements and radioactive sources. In addition, PET instrumentation is an area that has continued to evolve rapidly, especially over the last decade, with the emphases on increasing sensitivity, improving resolution, and decreasing patient scanning times. This chapter discusses the issues that are determinants of PET system performance. Much of the discussion is based on circular tomographs with discrete detectors, however, the principles are applicable also to flat detector systems and rotating gamma camera PET systems.

[1]  Gordon L. Brownell,et al.  A Multi-Crystal Positron Camera , 1972 .

[2]  M. J. Weber,et al.  Luminescence of Bi4 Ge3 O12 : Spectral and decay properties , 1973 .

[3]  J. C. Dainty,et al.  Image Science: Principles, Analysis and Evaluation of Photographic-Type Imaging Processes , 1974 .

[4]  G Muehllehner,et al.  Positron camera with extended counting rate capability. , 1975, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  T F Budinger,et al.  Analytical study of a high-resolution positron ring detector system for transaxial reconstruction tomography. , 1975, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  E. Hoffman,et al.  Application of annihilation coincidence detection to transaxial reconstruction tomography. , 1975, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  Z. Cho,et al.  Bismuth germanate as a potential scintillation detector in positron cameras. , 1977, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  M E Phelps,et al.  ECAT: a new computerized tomographic imaging system for positron-emitting radiopharmaceuticals. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  E. Hoffman,et al.  Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size , 1979, Journal of computer assisted tomography.

[10]  S. Derenzo Method for optimizing side shielding in positron-emission tomographs and for comparing detector materials. , 1980, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  M E Phelps,et al.  An analysis of signal amplification using small detectors in positron emission tomography. , 1982, Journal of computer assisted tomography.

[12]  Nicholas M. Spyrou,et al.  Imaging with ionizing radiations , 1982 .

[13]  C. Bohm,et al.  Correction for Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the Projections , 1983, Journal of computer assisted tomography.

[14]  R. F. Wagner,et al.  Low Contrast Sensitivity of Radiologic, CT, Nuclear Medicine, and Ultrasound Medical Imaging Systems , 1983, IEEE Transactions on Medical Imaging.

[15]  J. Mazziotta,et al.  Positron emission tomography and autoradiography , 1985 .

[16]  R. Nutt,et al.  A Multicrystal Two Dimensional BGO Detector System for Positron Emission Tomography , 1986, IEEE Transactions on Nuclear Science.

[17]  Joel S. Karp,et al.  Design and performance of a new positron tomograph , 1988 .

[18]  M Defrise,et al.  Three-dimensional image reconstruction from complete projections , 1989, Physics in medicine and biology.

[19]  M. Defrise,et al.  Three dimensional reconstruction of PET data from a multi-ring camera , 1989 .

[20]  Paul Kinahan,et al.  Analytic 3D image reconstruction using all detected events , 1989 .

[21]  D. Mankoff,et al.  Continuous-slice PENN-PET: a positron tomograph with volume imaging capability. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  E. Hoffman,et al.  Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalents counts , 1990 .

[23]  S R Cherry,et al.  3D PET using a conventional multislice tomograph without septa. , 1991, Journal of computer assisted tomography.

[24]  M. Gilardi,et al.  Noise Equivalent Count Measurements In A Neuro-pet Scanner With Retractable SEPTA , 1990, 1990 IEEE Nuclear Science Symposium Conference Record.

[25]  Steven R. Meikle,et al.  Effective sensitivity in 3D PET: the impact of detector dead time on 3D system performance , 1996 .

[26]  Ya. A. Ilyushin,et al.  On the theory of three-dimensional reconstruction , 1997 .

[27]  T J Spinks,et al.  The effect of activity outside the direct field of view in a 3D-only whole-body positron tomograph. , 1998, Physics in medicine and biology.

[28]  K. Cranley,et al.  Correction for deadtime losses in a gamma camera/data analysis system , 2004, European Journal of Nuclear Medicine.

[29]  Dale L. Bailey,et al.  A method for calibrating three-dimensional positron emission tomography without scatter correction , 1997, European Journal of Nuclear Medicine.

[30]  Dale L. Bailey,et al.  A method for measuring the absolute sensitivity of positron emission tomographic scanners , 1991, European Journal of Nuclear Medicine.