Research on Fluid Viscous Damper Parameters of Cable-Stayed Bridge in Northwest China

To optimize the aseismic performance of nonlinear fluid viscous dampers (FVD) of cable-stayed bridge in the highly seismic zone, Xigu Yellow River Bridge in northwest China is taken as an example. Nonlinear time-history analysis method is used to research on the relation among the internal forces, displacements, and damping parameters of the 650 tonnage FVD. The method of getting the minimum of binary functions is used to obtain the optimal parameters of FVD. Also, the 1 : 1 full-scale FVD model is made and used in the constitutive relation test. Then the test result of the damping parameters can be got by normal equation method. The optimized method to obtain the damping parameters is further verified. The results indicate that seismic response in key positions of the cable-stayed bridge can be reduced by installing longitudinal nonlinear FVD between the towers and girders if choosing reasonable damping parameters and . The optimal damping parameters can be calculated accurately by the proposed method of optimizing damping parameters of nonlinear FVD, and the constitutive relation test verifies the correctness of the optimization analysis method. Conclusions concerned can be applied to the design of nonlinear FVD for cable-stayed bridges.

[1]  Jianzhong Li,et al.  Lateral Isolation System of a Long-Span Cable-Stayed Bridge with Heavyweight Concrete Girder in a High Seismic Region , 2017 .

[2]  Timothy J. Sullivan,et al.  Towards a simplified Direct DBD procedure for the seismic design of moment resisting frames with viscous dampers , 2012 .

[3]  Andrei M. Reinhorn,et al.  Design of Supplemental Dampers for Control of Structures , 1996 .

[4]  Luca Landi,et al.  On the Design of Viscous Dampers for the Rehabilitation of Plan-Asymmetric Buildings , 2013 .

[5]  Wei Zhang,et al.  Seismic Design of a Long-Span Cable-Stayed Bridge with Fluid Viscous Dampers , 2016 .

[6]  J. Aguirre,et al.  Optimal control of linear and nonlinear asymmetric structures by means of passive energy dampers , 2013 .

[7]  Samer Barakat,et al.  Multiple regression modeling of natural rubber seismic-isolation systems with supplemental viscous damping for near-field ground motion , 2013 .

[8]  Giuseppe Carlo Marano,et al.  Identification of parameters of Maxwell and Kelvin–Voigt generalized models for fluid viscous dampers , 2015 .

[9]  T. T. Soong,et al.  Passive Energy Dissipation Systems in Structural Engineering , 1997 .

[10]  Francisco Paulo Lépore Neto,et al.  Modelling and experimental investigation of an active damper , 2006 .

[11]  Xia Zhang,et al.  Estimation of the optimum parameters of fluid viscous dampers for seismic response control of highway bridges , 2010, Proceedings of the 29th Chinese Control Conference.

[12]  Gary F. Dargush,et al.  Analytical Model of Viscoelastic Fluid Dampers , 1993 .

[13]  Samuele Infanti,et al.  Special Fluid Viscous Dampers For The Messina Strait Bridge , 2008 .

[14]  Wei Chen,et al.  Theoretical Analysis on the Damping Characteristics of a Clearance Type Viscous Damper , 2012 .

[15]  Dilip I. Narkhede,et al.  Behavior of nonlinear fluid viscous dampers for control of shock vibrations , 2014 .

[16]  Cole C. McDaniel,et al.  Influence of Dampers on Seismic Response of Cable-Supported Bridge Towers , 2007 .

[17]  Nicos Makris,et al.  Viscous heating of fluid dampers under small and large amplitude motions : Experimental studies and parametric modeling , 2007 .

[18]  Jiu Hong Jia,et al.  Test Verification of a Design Method for a Fluid Viscous Damper , 2011 .

[19]  R. S. Jangid,et al.  Influence of soil : structure interaction on the response of seismically isolated cable-stayed bridge , 2008 .

[20]  M. D. Martínez-Rodrigo,et al.  Dynamic performance of existing high-speed railway bridges under resonant conditions retrofitted with fluid viscous dampers , 2010 .

[21]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[22]  Fahim Sadek,et al.  Linear Procedures for Structures with Velocity-Dependent Dampers , 2000 .

[23]  Hongping Zhu,et al.  Optimum Design of Passive Control Devices for Reducing the Seismic Response of Twin-Tower-Connected Structures , 2018 .

[24]  Liu Jian-xin Parametric Sensitivity Study on Fluid Viscous Damper of Long Span Suspension Bridge , 2011 .

[25]  Tomaso Trombetti,et al.  Physical and Numerical Approaches for the Optimal Insertion of Seismic Viscous Dampers in Shear-Type Structures , 2007 .

[26]  Tomaso Trombetti,et al.  A Five-Step Procedure for the Dimensioning of Viscous Dampers to Be Inserted in Building Structures , 2010 .

[27]  Yu Min Zhang,et al.  Parametric Sensitivity Study on Fluid Viscous Damper of Long Span Suspension Bridge , 2011 .

[28]  Luca Landi,et al.  A Methodology for the Direct Assessment of the Damping Ratio of Structures Equipped with Nonlinear Viscous Dampers , 2012 .

[29]  Costas P. Providakis,et al.  Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations , 2008 .

[30]  A. Suresh,et al.  Numerical study of magnetic circuit response in magneto-rheological damper , 2016 .

[31]  Liu Jian-she Parametric analysis of viscous dampers for earthquake mitigation of continuous bridges in high intensity region , 2012 .

[32]  W. Marsden I and J , 2012 .

[33]  Michael C. Constantinou,et al.  Experimental & Analytical Investigation of Seismic Response of Structures With Supplemental Fluid Viscous Dampers , 1992 .

[34]  Ding Wangxing Effects of Viscous Damper Parameters on Anti-seismic Performance of Long-span Bridge , 2009 .

[35]  Kohju Ikago,et al.  Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper , 2012 .