Experimental and numerical analysis of lightweight radiant floor heating system

Abstract The operating characteristics of lightweight radiant floor heating (LRFH) system were analyzed by experiments and numerical calculation. A heat transfer model for the evaluation of LRFH system was investigated and a corresponding calculation program was developed. The effects of design parameters on performance of LRFH system were studied by means of calculation program previously validated through an experimental campaign performed in a laboratory. Meanwhile, the heat-transfer capability, temperature field distribution and thermal comfort of LRFH system were analyzed by experiments. The results indicate that LRFH system shows fine thermal stability and thermal comfort.

[1]  Qiu Lin Experimental Research of Running Mode on the Dry Structure Floor Heating System , 2004 .

[2]  Byung-Cheon Ahn,et al.  Control characteristics and heating performance analysis of automatic thermostatic valves for radiant slab heating system in residential apartments , 2010 .

[3]  Maxime Tye-Gingras,et al.  Investigation on heat transfer modeling assumptions for radiant panels with serpentine layout , 2011 .

[4]  Wang Wen-hai Feasibility study on Floor Heating by Application of Prestressed Concrete Hollow Floor and Dry Floor Structure , 2005 .

[5]  Lucia Fontana,et al.  Experimental study on the globe thermometer behaviour in conditions of asymmetry of the radiant temperature , 2010 .

[6]  Bjarne W. Olesen,et al.  Radiant Floor Heating In Theory and Practice , 2002 .

[7]  Jesper Kragh,et al.  Modelling floor heating systems using a validated two-dimensional ground-coupled numerical model , 2005 .

[8]  Svend Svendsen,et al.  Method for calculating thermal properties of lightweight floor heating panels based on an experimental setup , 2005 .

[9]  Jungki Seo,et al.  Thermal performance analysis according to wood flooring structure for energy conservation in radiant floor heating systems , 2011 .

[10]  You Min-yu Research on a light dry floor radiant heating system combined with floor decoration , 2006 .

[11]  Bijan Farhanieh,et al.  A parametric study on radiant floor heating system performance , 2006 .

[12]  Jianlei Niu,et al.  A review of the application of radiant cooling & heating systems in Mainland China , 2012 .

[13]  Richard Karl Strand,et al.  Modeling radiant heating and cooling systems: integration with a whole-building simulation program , 2005 .

[14]  Xiaosong Zhang,et al.  A calculation method for the floor surface temperature in radiant floor system , 2010 .

[15]  Lucia Fontana,et al.  Thermal performance of radiant heating floors in furnished enclosed spaces , 2011 .

[16]  Abdelaziz Laouadi Development of a radiant heating and cooling model for building energy simulation software , 2004 .

[17]  Jungki Seo,et al.  High thermal performance composite PCMs loading xGnP for application to building using radiant floor heating system , 2012 .