Recommendations for isolation monitor ground fault detectors on residential and utility-scale PV systems

PV faults have caused rooftop fires in the U.S., Europe, and elsewhere in the world. One prominent cause of past electrical fires was the ground fault detection “blind spot” in fuse-based protection systems uncovered by the Solar America Board for Codes and Standards (SolarABCs) steering committee in 2011. Fortunately, a number of alternatives to ground fault fuses have been identified, but there has been limited adoption and historical use of these technologies in the United States. This paper investigates the efficacy of one of these devices known as isolation monitoring (or isolation resistance monitoring, Riso) in small (~3kW) and large (~700 kW) arrays. Unfaulted and faulted PV arrays were monitored with Riso technology and compared to SPICE simulations to recommend appropriate thresholds to the maximize the range of ground faults which could be detected while minimizing unwanted tripping. Based on analytical and computational models, it is impossible to determine a trip threshold that provides fire safety and negates unwanted tripping issues. This paper mathematically demonstrates that appropriate Riso trip thresholds must be determined on an array-by- array basis with sufficient leeway by system operators to adjust trip threshold settings for their particular usage cases.

[1]  Fei Zhou,et al.  Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid , 2008, 2008 IEEE International Conference on Sustainable Energy Technologies.

[2]  Jay Johnson,et al.  Photovoltaic ground fault and blind spot electrical simulations. , 2013 .

[3]  P. G. Vidal,et al.  Characterization of the insulation and leakage currents of PV generators: Relevance for human safety , 2010 .

[4]  Remus Teodorescu,et al.  Leakage current evaluation of a singlephase transformerless PV inverter connected to the grid , 2007, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.

[5]  Jay Johnson,et al.  Recommendations for RCD Ground Fault Detector Trip Thresholds , 2014 .

[6]  Jay Johnson,et al.  Recommendations for CSM and Riso ground fault detector trip thresholds , 2014, 2014 IEEE 40th Photovoltaic Specialist Conference (PVSC).

[7]  Jay Johnson,et al.  Electrical simulations of series and parallel PV arc-faults , 2013, 2013 IEEE 39th Photovoltaic Specialists Conference (PVSC).

[8]  Ninoslav Simić Low-voltage electrical installations in medical buildings - clinical centres and hospitals , 2015 .

[9]  W. Bower,et al.  Analysis of grounded and ungrounded photovoltaic systems , 1994, Proceedings of 1994 IEEE 1st World Conference on Photovoltaic Energy Conversion - WCPEC (A Joint Conference of PVSC, PVSEC and PSEC).

[10]  Yandan Lin,et al.  Analysis on Leakage Current in Transformerless Single-Phase PV Inverters Connected to the Grid , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.