In July of 1995, Lockheed Martin IR Imaging Systems, of Lexington, Massachusetts began the development of an integrated sniper location system for the Defense Advanced Research Projects Agency and for the Department of the Navy's Naval Command Control & Ocean Surveillance Center, RDTE Division in San Diego, California. The I-SLS integrates acoustic and uncooled infrared sensing technologies to provide an affordable and highly effective sniper detection and location capability. This system, its performance and results from field tests at Camp Pendleton, California, in October 1996 were described in a paper presented at the November 1996 SPIE Photonics East Symposium1 on Enabling Technologies for Law Enforcement and Security. The I-SLS combines an acoustic warning system with an uncooled infrared warning system. The acoustic warning system has been developed by SenTech, Inc., of Lexington, Massachusetts. This acoustic warning system provides sniper detection and coarse location information based upon the muzzle blast of the sniper's weapon and/or upon the shock wave produced by the sniper's bullet, if the bullet is supersonic. The uncooled infrared warning system provides sniper detection and fine location information based upon the weapon's muzzle flash. In addition, the uncooled infrared warning system can provide thermal imagery that can be used to accurately locate and identify the sniper. Combining these two technologies improves detection probability, reduces false alarm rate and increases utility. In the two years since the last report of the integrated sniper location system, improvements have been made and a second field demonstration was planned. In this paper, we describe the integrated sniper location system modifications in preparation for the new field demonstration. In addition, fundamental improvements in the uncooled infrared sensor technology continue to be made. These improvements include higher sensitivity (lower minimum resolvable temperature), higher spatial resolution, and smaller size. This paper will describe the implementation and status of these improvements.
[1]
Thomas B. Breen,et al.
Applications of uncooled microbolometer sensors
,
1998,
Defense, Security, and Sensing.
[2]
Burton D. Figler,et al.
Uncooled infrared sensors for an integrated sniper location system
,
1997,
Defense + Security Symposium.
[3]
Charles A. Marshall,et al.
Quantitative and imaging performance of uncooled microbolometer sensors for medical applications
,
1997,
Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).
[4]
Neal R. Butler,et al.
Low-cost uncooled microbolometer imaging system for dual use
,
1995,
Optics & Photonics.
[5]
Margaret Kohin,et al.
Uncooled infrared sensors for surveillance and law enforcement applications
,
1997,
Defense + Security Symposium.
[6]
Charles A. Marshall,et al.
Uncooled infrared sensor with digital focal plane array for medical applications
,
1996,
Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[7]
Thomas B. Breen,et al.
Uncooled infrared sensors with digital focal plane array
,
1996,
Defense + Commercial Sensing.
[8]
Thomas B. Breen,et al.
Quantitative and imaging performance of uncooled microbolometer sensors
,
1997,
Defense, Security, and Sensing.
[9]
James W. Hoffman.
Early test results from the uncooled thermal imaging radiometer (TIR)
,
1997,
Optics & Photonics.