Rapid and accurate determination of tissue optical properties using least-squares support vector machines

Diffuse reflectance spectroscopy (DRS) has been extensively applied for the characterization of biological tissue, especially for dysplasia and cancer detection, by determination of the tissue optical properties. A major challenge in performing routine clinical diagnosis lies in the extraction of the relevant parameters, especially at high absorption levels typically observed in cancerous tissue. Here, we present a new least-squares support vector machine (LS-SVM) based regression algorithm for rapid and accurate determination of the absorption and scattering properties. Using physical tissue models, we demonstrate that the proposed method can be implemented more than two orders of magnitude faster than the state-of-the-art approaches while providing better prediction accuracy. Our results show that the proposed regression method has great potential for clinical applications including in tissue scanners for cancer margin assessment, where rapid quantification of optical properties is critical to the performance.

[1]  Johan A. K. Suykens,et al.  Least Squares Support Vector Machines , 2002 .

[2]  B. Tromberg,et al.  Monitoring neoadjuvant chemotherapy in breast cancer using quantitative diffuse optical spectroscopy: a case study. , 2004, Journal of biomedical optics.

[3]  Anthony J. Durkin,et al.  Reflectance-based determination of optical properties in highly attenuating tissue. , 2003, Journal of biomedical optics.

[4]  Arjen Amelink,et al.  Measurement of the local optical properties of turbid media by differential path-length spectroscopy. , 2004, Applied optics.

[5]  Nello Cristianini,et al.  An Introduction to Support Vector Machines and Other Kernel-based Learning Methods , 2000 .

[6]  G. Zonios,et al.  Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo. , 1999, Applied optics.

[7]  Anthony J. Durkin,et al.  Lookup-table method for imaging optical properties with structured illumination beyond the diffusion theory regime. , 2010, Journal of biomedical optics.

[8]  Michael S Feld,et al.  Development of robust calibration models using support vector machines for spectroscopic monitoring of blood glucose. , 2010, Analytical chemistry.

[9]  R. Steiner,et al.  Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue. , 1996, Applied optics.

[10]  B. Wilson,et al.  A diffusion theory model of spatially resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. , 1992, Medical physics.

[11]  Michele Follen,et al.  Reflectance spectroscopy for in vivo detection of cervical precancer. , 2002, Journal of biomedical optics.

[12]  Sergio Fantini,et al.  Characterization of spatial and temporal variations in the optical properties of tissuelike media with diffuse reflectance imaging. , 2003, Applied optics.

[13]  Narasimhan Rajaram,et al.  Lookup table-based inverse model for determining optical properties of turbid media. , 2008, Journal of biomedical optics.

[14]  Johan A. K. Suykens,et al.  LS-SVMlab : a MATLAB / C toolbox for Least Squares Support Vector Machines , 2007 .

[15]  T. Scheeren,et al.  Clinical evaluation of reflectance spectrophotometry for the measurement of gastric microvascular oxygen saturation in patients undergoing cardiopulmonary bypass. , 2002, Journal of cardiothoracic and vascular anesthesia.

[16]  Michele Follen,et al.  Diffuse reflectance patterns in cervical spectroscopy. , 2005, Gynecologic oncology.

[17]  Bing Yu,et al.  Performance metrics of an optical spectral imaging system for intra-operative assessment of breast tumor margins , 2010, Optics express.

[18]  M S Patterson,et al.  The use of a neural network to determine tissue optical properties from spatially resolved diffuse reflectance measurements. , 1992, Physics in medicine and biology.

[19]  Roberto Reif,et al.  Analytical model of light reflectance for extraction of the optical properties in small volumes of turbid media. , 2007, Applied optics.

[20]  Andrew J Berger,et al.  Correction method for absorption-dependent signal enhancement by a liquid-core optical fiber. , 2006, Applied optics.

[21]  Alexander J. Smola,et al.  Learning with kernels , 1998 .

[22]  S L Jacques,et al.  In vivo determination of optical properties of normal and tumor tissue with white light reflectance and an empirical light transport model during endoscopy. , 2005, Journal of biomedical optics.

[23]  R. Brereton,et al.  Support vector machines for classification and regression. , 2010, The Analyst.

[24]  L. Buydens,et al.  Multivariate calibration with least-squares support vector machines. , 2004, Analytical chemistry.

[25]  D W Rattner,et al.  Reflectance spectroscopy of pancreatic microcirculation. , 1996, Journal of applied physiology.

[26]  Thomas H. Foster,et al.  Steady-state reflectance spectroscopy in the P 3 approximation , 2001 .

[27]  Stefan Andersson-Engels,et al.  Least-squares support vector machines modelization for time-resolved spectroscopy. , 2005, Applied optics.

[28]  N. Ramanujam,et al.  Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms. , 2006, Applied optics.

[29]  I Itzkan,et al.  An enhanced algorithm for linear multivariate calibration. , 1998, Analytical chemistry.

[30]  M. Forina,et al.  Multivariate calibration. , 2007, Journal of chromatography. A.

[31]  Xueguang Shao,et al.  Multivariate calibration methods in near infrared spectroscopic analysis , 2010 .

[32]  B. Hooper Optical-thermal response of laser-irradiated tissue , 1996 .