Implementation of a building foundation heat transfer model in EnergyPlus

In this article, a two-dimensional transient ground-coupled numerical model for slab-on-grade foundation is developed and integrated into EnergyPlus. A verification analysis is first presented to ensure that the developed building foundation heat transfer module is properly implemented within EnergyPlus. Then, predictions from the developed model are compared with those obtained from a simplified building foundation model currently used in EnergyPlus. Finally, the impact of several foundation insulation configurations on the annual variation of both heating and cooling loads is investigated for a one-storey single-family ranch house. The results show that the developed foundation heat transfer module accounts more accurately for the effects of the ground thermal mass than the foundation model currently used in EnergyPlus. In particular, it was found that annual heating and cooling loads can be overestimated by over 20% for a typical residential building if ground-coupled heat transfer calculations are not fully integrated in EnergyPlus.

[1]  P. J. Walsh,et al.  Application of Fourier transforms to periodic heat flow into the ground under a building , 1983 .

[2]  Marvin E. Jensen,et al.  Consumptive use of water and irrigation water requirements : a report , 1973 .

[3]  C. Pedersen,et al.  A three-dimensional numerical study of slab-on-grade heat transfer , 1990 .

[4]  John E. Seem Modeling of Heat Transfer in Buildings , 1987 .

[5]  Daniel E. Fisher,et al.  EnergyPlus: creating a new-generation building energy simulation program , 2001 .

[6]  Moncef Krarti,et al.  A simulation method for fluctuating temperatures in crawlspace foundations , 1997 .

[7]  Moncef Krarti,et al.  Local/global analysis of transient heat transfer from building foundations , 2004 .

[8]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[9]  William P. Bahnfleth,et al.  Three-Dimensional Modelling of Heat Transfer from Slab Floors , 1989 .

[10]  T. Kusuda,et al.  EARTH TEMPERATURE AND THERMAL DIFFUSIVITY AT SELECTED STATIONS IN THE UNITED STATES , 1965 .

[11]  C. O. Pedersen,et al.  Investigation of outside heat balance models for use in a heat balance cooling load calculation procedure , 1997 .

[12]  C. O. Pedersen,et al.  An evaluation of inside surface heat balance models for cooling load calculations , 1997 .

[13]  Moncef Krarti,et al.  Steady-Periodic Three-Dimensional Foundation Heat Transfer From Refrigerated Structures , 2000 .

[14]  George D. Meixel,et al.  A COMPUTER SIMULATION OF THE THERMAL PERFORMANCE OF EARTH COVERED ROOFS , 1981 .

[15]  Richard Karl Strand Heat source transfer functions and their application to low temperature radiant heating systems , 1995 .

[16]  R. Judkoff,et al.  International Energy Agency Building Energy Simulation Test and Diagnostic Method (IEA BESTEST) In-Depth Diagnostic Cases for Ground Coupled Heat Transfer Related to Slab-On-Grade Construction , 2008 .

[17]  David E. Claridge,et al.  Design Methods for Earth-Contact Heat Transfer , 1988 .