Penetration of Particles into Buildings and Associated Physical Factors. Part I: Model Development and Computer Simulations

The PM2.5 standard proposed by the U.S. Environmental Protection Agency (EPA) has stimulated research on the relationships between particulate matter concentrations and the exposures and subsequent health responses of sensitive subpopulations, such as the elderly. Since individuals in these subpopulations may spend more than 90% of their time indoors, understanding the relationship between outdoor particle concentrations and those found in indoor microenvironments is critical. This research resulted in a time-dependent indoor air quality model incorporating all potential particle sources and loss mechanisms. Monte Carlo simulations of the model identified the mechanisms, such as particle loss during penetration through the building envelope, that modify the outdoor particle size distribution during transport into the interior of a building, calculated indoor-to-outdoor (I/O) concentration ratios, and estimated penetration factors as a function of particle size. Indoor particle generation and transport of outdoor particles through the HVAC system were the most important contributors to the indoor concentration in residential and commercial buildings, respectively. The most significant removal mechanisms included ventilation through and particle removal by the HVAC filter if an HVAC system was present, or particle deposition on indoor surfaces if an HVAC system was not present. The modeled I/O concentration ratios varied between 0.05 and 0.5, depending on particle size and type of ventilation system, and agreed well with published experimental results. Penetration factors less than unity were calculated for particles with aerodynamic diameters larger than 0.2 θ m if the air exchange rate and steady-state I/O concentration ratio were correlated during the simulations. An additional correlation between the air exchange rate and particle deposition velocity is required if penetration factors less than unity are to be modeled for particles with aerodynamic diameters smaller than 0.2 θ m. These results

[1]  H. N. Jow,et al.  Indoor-outdoor relationships for airborne particulate matter of outdoor origin , 1979 .

[2]  Gerald E. Anderson,et al.  MODELING THE INDOOR ENVIRONMENT , 1992 .

[3]  John Burnett,et al.  A methodology to investigate the particulate penetration coefficient through building shell , 1999 .

[4]  Lockheed Martin A Multiple-Smoker Model for Predicting Indoor Air Quality in Public Lounges , 1996 .

[5]  David T. Grimsrud,et al.  Control of respirable particles in indoor air with portable air cleaners , 1985 .

[6]  L. Wallace,et al.  Indoor particles: a review. , 1996, Journal of the Air & Waste Management Association.

[7]  David E. Burmaster,et al.  Residential Air Exchange Rates in the United States: Empirical and Estimated Parametric Distributions by Season and Climatic Region , 1995 .

[8]  Charles J. Weschler,et al.  Indoor/outdoor concentrations and indoor surface accumulations of ionic substances , 1985 .

[9]  M St,et al.  National Ambient Air Quality Standards for Particulate Matter: Proposed Decision AGENCY: Environmental Protection , 1996 .

[10]  S Lewis,et al.  Solid particle penetration into enclosures , 1995 .

[11]  William W. Nazaroff,et al.  Mathematical Modeling of Indoor Aerosol Dynamics , 1989 .

[12]  Antony J. H. Goddard,et al.  Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios , 1997 .

[13]  John D. Spengler,et al.  Indoor-outdoor relationships of respirable sulfates and particles , 1981 .

[14]  Peter H. McMurry,et al.  AIR AND AEROSOL INFILTRATION IN HOMES. , 1985 .

[15]  Tracy L. Thatcher,et al.  Deposition, resuspension, and penetration of particles within a residence , 1995 .

[16]  E. Knutson,et al.  Indoor Outdoor Aerosol Measurements for Two Residential Buildings in New Jersey , 1988 .

[17]  David S. Ensor,et al.  Fractional Aerosol Filtration Efficiency of In‐Duct Ventilation Air Cleaners , 1994 .

[18]  J. Behar,et al.  Modeling indoor air concentrations near emission sources in imperfectly mixed rooms. , 1996, Journal of the Air & Waste Management Association.

[19]  Markus Olin,et al.  Indoor Air Aerosol Model: Transport Indoors and Deposition of Fine and Coarse Particles , 1989 .

[20]  John H. Seinfeld,et al.  Turbulent deposition and gravitational sedimentation of an aerosol in a vessel of arbitrary shape , 1981 .