Planar Transformers With Near-Zero Common-Mode Noise for Flyback and Forward Converters

Flyback and forward converters are two commonly used topologies for isolated low-power applications. These converters are simple and cost effective and provide galvanic isolation, which make them desirable for low-power levels. In order to enhance the performance of these converters, planar transformers (PTs) can be used that feature lower height, considerably lower leakage inductance, excellent thermal characteristics, and repeatability. Selecting a proper winding arrangement for a PT is a significant challenge, in particular given the large capacitances involved in flat structures. While interleaved structures significantly reduce the ac resistance and leakage inductance of PTs, they also lead to very large interwinding capacitance, which produces significant levels of undesired common-mode (CM) noise that causes EMI problems. Reducing interwinding capacitance by using noninterleaved structures is not an ideal solution to the CM noise problem because of its side effects. Instead, this paper tackles the problem by proposing the concept of paired layers. According to this concept, there are layers in the primary and secondary sides that have the same $dv/dt$, and therefore, their overlapping does not generate CM noise. These layers can be used to design highly interleaved structures that not only have very low ac resistance and leakage inductance, but also generate almost zero CM noise, although they may have a very large interwinding capacitance. In addition, a detailed parasitic capacitance model of PTs is proposed, which analytically validates the proposed concept and method. The experimental results show that the proposed PTs not only have very low ac resistance and leakage inductance, but also generate extremely low levels of CM noise. Considering that the proposed PT has interwinding capacitance equal to $\text{700 pF}$ , it is very interesting to see that it generates significantly less CM noise than does a traditional wire-wound transformer that has only $\text{10-pF}$ parasitic capacitance. Therefore, the proposed method gives designers the opportunity to minimize ac resistance and leakage inductance by using highly interleaved structures, without having to worry about CM noise caused by large interwinding capacitance.

[1]  Shuo Wang,et al.  A Generalized Common-Mode Current Cancelation Approach for Power Converters , 2015, IEEE Transactions on Industrial Electronics.

[2]  Fred C. Lee,et al.  Analysis and reduction of common mode EMI noise for resonant converters , 2014, 2014 IEEE Applied Power Electronics Conference and Exposition - APEC 2014.

[3]  P. K. Jain,et al.  An Improved Layout Strategy for Common-Mode EMI Suppression Applicable to High-Frequency Planar Transformers in High-Power DC/DC Converters Used for Electric Vehicles , 2014, IEEE Transactions on Power Electronics.

[4]  Dushan Boroyevich,et al.  Passive cancellation of common-mode noise in power electronic circuits , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[5]  Zhe Zhang,et al.  Primary parallel secondary series flyback converter (PPSSFC) with multiple transformers for very high step-up ratio in capacitive load charging applications , 2014, 2014 IEEE Applied Power Electronics Conference and Exposition - APEC 2014.

[6]  Martin Ordonez,et al.  Low parasitics planar transformer for LLC resonant battery chargers , 2016, 2016 IEEE Applied Power Electronics Conference and Exposition (APEC).

[7]  F.C. Lee,et al.  Analysis and suppression of conducted EMI emissions for front-end LLC resonant DC/DC converters , 2008, 2008 IEEE Power Electronics Specialists Conference.

[8]  Fred C. Lee,et al.  Transformer structure and its effects on common mode EMI noise in isolated power converters , 2010, 2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[9]  Shehab Ahmed,et al.  Flyback converter with novel active clamp control and secondary side post regulator for low standby power consumption under high-efficiency operation , 2011 .

[10]  F. Dawson,et al.  Characterizations of High Frequency Planar Transformer With a Novel Comb-Shaped Shield , 2011, IEEE Transactions on Magnetics.

[11]  Junwei Lu,et al.  Structure Comparison of High-Frequency Planar Power Integrated Magnetic Circuits , 2011, IEEE Transactions on Magnetics.

[12]  Xinbo Ruan,et al.  Shielding-cancellation technique for suppressing common mode EMI in isolated power converters , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[13]  Concettina Buccella,et al.  A Coupled Electrothermal Model for Planar Transformer Temperature Distribution Computation , 2008, IEEE Transactions on Industrial Electronics.

[14]  W. G. Hurley,et al.  Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt , 2014 .

[15]  Xinbo Ruan,et al.  Shielding-Cancelation Technique for Suppressing Common-Mode EMI in Isolated Power Converters , 2015, IEEE Transactions on Industrial Electronics.

[16]  Weihao Hu,et al.  Conducted EMI Mitigation Schemes in Isolated Switching-Mode Power Supply Without the Need of a Y-Capacitor , 2017, IEEE Transactions on Power Electronics.

[17]  S. Djuric,et al.  A Compact Planar Transformer With an Improved Winding Configuration , 2014, IEEE Transactions on Magnetics.

[18]  Dan Zhang,et al.  EMI noise cancelation by optimizing transformer design without need for the traditional Y-capacitor , 2016, 2016 IEEE Applied Power Electronics Conference and Exposition (APEC).

[19]  Martin Ordonez,et al.  LLC Converters With Planar Transformers: Issues and Mitigation , 2017, IEEE Transactions on Power Electronics.

[20]  F. Blache,et al.  Stray capacitances of two winding transformers: equivalent circuit, measurements, calculation and lowering , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.

[21]  Yan Xing,et al.  Families of Forward Converters Suitable for Wide Input Voltage Range Applications , 2014, IEEE Transactions on Power Electronics.

[22]  Martin Ordonez,et al.  Planar transformer winding technique for reduced capacitance in LLC power converters , 2016, 2016 IEEE Energy Conversion Congress and Exposition (ECCE).

[23]  Pingping Chen,et al.  The passive EMI cancellation effects of Y capacitor and CM model of transformers used in switching mode power supplies (SMPS) , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[24]  Yick Po Chan,et al.  Effective switching mode power supplies common mode noise cancellation technique with zero equipotential transformer models , 2010, 2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[25]  Chen Wei An Evaluation Method of Transformer Behaviors on the Suppression of Common-mode Conduction Noise in Switch Mode Power Supply , 2012 .

[26]  Henglin Chen,et al.  Determination of Transformer Shielding Foil Structure for Suppressing Common-Mode Noise in Flyback Converters , 2016, IEEE Transactions on Magnetics.

[27]  Michael A. E. Andersen,et al.  Overview of Planar Magnetic Technology—Fundamental Properties , 2014, IEEE Transactions on Power Electronics.

[28]  N. K. Poon,et al.  Common-Mode Noise Cancellation by an Antiphase Winding in Multilayer Isolated Planar Transformer , 2014, IEEE Transactions on Electromagnetic Compatibility.

[29]  Ehsan Adib,et al.  Family of Soft-Switching Single-Switch PWM Converters With Lossless Passive Snubber , 2015, IEEE Transactions on Industrial Electronics.

[30]  E. Waffenschmidt,et al.  Analytical modelling of winding capacitances and dielectric losses for planar transformers , 2004, 2004 IEEE Workshop on Computers in Power Electronics, 2004. Proceedings..

[31]  Michael A. E. Andersen,et al.  Optimal Design and Tradeoff Analysis of Planar Transformer in High-Power DC–DC Converters , 2012, IEEE Transactions on Industrial Electronics.

[32]  Shuo Wang,et al.  Reducing Common-Mode Noise in Two-Switch Forward Converter , 2011, IEEE Transactions on Power Electronics.