Prestresses around the acetabulum generated by screwed cups.

Screwed acetabular cups, applied in total hip replacements, generate stresses in the surrounding bone during implantation (prestresses). The effect of these prestresses on the endurance of the hip replacement are unknown. The prestresses in the acetabulum were examined both experimentally, using strain gauge techniques, and numerically, using the finite element method. It was found that the prestresses were of the same order of magnitude, if not larger, than the stresses due to the hip reaction force during one-legged stance. In some cases, the prestresses even approximated the ultimate tensile strength of cortical bone. The prestresses seemed to have a strong dependence on the outer shape of the cup, rather than on the flexibility of the cup or whether the cup had a self-cutting thread or not. Furthermore, it was found that the prestresses are not very susceptible to stress relaxation due to the visco-elastic behaviour of bone. This means that prestresses will remain present over long periods of time. So even when a patient has resumed normal daily activities, the prestresses will still play an important role in the overall stress distributions around the acetabulum. Due to the interaction of prestresses and stresses due to normal loading, the primary stability of a metal-backed screwed cup is better guaranteed than the primary stability of an all-polyethylene screwed cup.

[1]  C. Dietschi,et al.  Mechanical function of subchondral bone as experimentally determined on the acetabulum of the human pelvis. , 1976, Journal of biomechanics.

[2]  R. Crowninshield,et al.  A stress analysis of acetabular reconstruction in protrusio acetabuli. , 1983, The Journal of bone and joint surgery. American volume.

[3]  D R Carter,et al.  Stress distributions in the acetabular region--II. Effects of cement thickness and metal backing of the total hip acetabular component. , 1982, Journal of biomechanics.

[4]  J. Charnley,et al.  Radiological demarcation of cemented sockets in total hip replacement. , 1976, Clinical orthopaedics and related research.

[5]  D R Carter,et al.  Stress distributions in the acetabular region--I. Before and after total joint replacement. , 1982, Journal of biomechanics.

[6]  G. Lord,et al.  The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study. , 1983, Clinical orthopaedics and related research.

[7]  N L Svensson,et al.  Stresses in the normal pelvis. , 1978, Computers in biology and medicine.

[8]  A. Burstein,et al.  The elastic and ultimate properties of compact bone tissue. , 1975, Journal of biomechanics.

[9]  R. N. Stauffer Ten-year follow-up study of total hip replacement. , 1982, The Journal of bone and joint surgery. American volume.

[10]  R. Huiskes,et al.  Fem analyses of hip prostheses: Validity of the 2-D side-plate model and the effects of torsion , 1991 .

[11]  T. Slooff,et al.  Stress Transfer Across the Hip Joint in Reconstructed Acetabuli , 1987 .

[12]  Hwj Rik Huiskes,et al.  Finite element analysis of acetabular reconstruction. Noncemented threaded cups. , 1987, Acta orthopaedica Scandinavica.

[13]  J. Kärrholm,et al.  PRIMARY MIGRATION OF FULLY-THREADED ACETABULAR PROSTHESES , 1990 .

[14]  D. J. Rapperport,et al.  Contact finite element stress analysis of the hip joint , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[15]  H Oonishi,et al.  Mechanical analysis of the human pelvis and its application to the artificial hip joint--by means of the three dimensional finite element method. , 1983, Journal of biomechanics.

[16]  D R Pedersen,et al.  An axisymmetric model of acetabular components in total hip arthroplasty. , 1982, Journal of biomechanics.

[17]  A. Burstein,et al.  The elastic modulus for bone. , 1974, Journal of biomechanics.