Automatic detection of coronary artery anastomoses in epicardial ultrasound images

PurposeEpicardial ultrasound (EUS) can be used to assess the quality of coronary artery bypass graft surgery (CABG) anastomoses by determining stenotic rates. Currently, no objective quantitative methods are available for the analysis of EUS images. Therefore, surgeons have to be trained in interpreting EUS images, which may limit the use of EUS in clinical practice. Automatic detection of vessel structures can enable the objective and quantitative quality assessment of anastomoses without user interaction to facilitate the revision of anastomoses during the primary surgery.MethodsAn automatic vessel detection algorithm extracted and detected image regions that uniquely intersected with the vessel lumen of anastomotic structures. First, an initial pixel-based segmentation was performed from regional minimums using a watershed segmentation and an adaptive thresholding approach. A region-based merging step was then performed to merge oversegmented vessel structures using a Bayesian classification of different region combinations constructed from the pixel-based segmentations. Finally, a vessel classification step was performed on the extracted regions after the region-based merging to determine the probabilities that the regions contained vessel structures.ResultsThe performance of the vessel classifier was tested using m-fold cross-validation of 320 EUS images containing anastomotic vessel structures from 16 anastomoses made on healthy porcine vessels. An area under the curve of 0.966 (95 % CI 0.951–0.984) and 0.989 (95 % CI 0.985–0.993, $${ {p}} < 0.001$$p<0.001) of a precision–recall and receiver operator characteristic curve, respectively, was obtained when detecting vessel regions extracted from the EUS images.ConclusionsThe vessel detection algorithm can detect vessel regions in EUS images at a high accuracy. It can be used to enable the automatic analysis of EUS images for the quality assessment of CABG anastomoses.

[1]  Shubao Liu,et al.  Tracking of Carotid Arteries in Ultrasound Images , 2013, MICCAI.

[2]  L. Gray,et al.  Role of graft flow measurement technique in anastomotic quality assessment in minimally invasive CABG. , 1998, The Annals of thoracic surgery.

[4]  R. Haaverstad,et al.  Intraoperative color Doppler ultrasound assessment of anastomoses of the left internal mammary artery to the left anterior descending coronary artery during off-pump coronary artery bypass surgery correlates with angiographic evaluation at the 8-month follow-up. , 2003, The heart surgery forum.

[5]  M. Penco,et al.  Intraoperative graft verification in coronary surgery: increased diagnostic accuracy adding high-resolution epicardial ultrasonography to transit-time flow measurement. , 2014, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[6]  Jacob Bergsland,et al.  Epicardial ultrasonography: a potential method for intraoperative quality assessment of coronary bypass anastomoses? , 2007, The Annals of thoracic surgery.

[7]  Fernand Meyer,et al.  Topographic distance and watershed lines , 1994, Signal Process..

[8]  J. Alison Noble,et al.  Integration of Local and Global Features for Anatomical Object Detection in Ultrasound , 2012, MICCAI.

[9]  M. Mack,et al.  Intraoperative coronary graft assessment , 2008, Current opinion in cardiology.

[10]  Ian T. Jolliffe,et al.  Principal Component Analysis , 2002, International Encyclopedia of Statistical Science.

[11]  K. S. Nikita,et al.  Automated detection of the carotid artery wall in B-mode ultrasound images using active contours initialized by the Hough transform , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  Hans Torp,et al.  Intraoperative color Doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting. , 2002, The Annals of thoracic surgery.

[13]  R. Budde,et al.  Detection of construction errors in ex vivo coronary artery anastomoses by 13-MHz epicardial ultrasonography. , 2005, The Journal of thoracic and cardiovascular surgery.

[14]  Jitendra Malik,et al.  Recovering human body configurations: combining segmentation and recognition , 2004, Proceedings of the 2004 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, 2004. CVPR 2004..

[15]  Lasse Riis Østergaard,et al.  Semi-automatic vessel tracking and segmentation using epicardial ultrasound in bypass surgery , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  Rafael C. González,et al.  Local Determination of a Moving Contrast Edge , 1985, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[17]  M. Mack,et al.  Results of graft patency by immediate angiography in minimally invasive coronary artery surgery. , 1999, The Annals of thoracic surgery.

[18]  J. Andreasen,et al.  A new technique facilitating intraoperative, high-frequency echocardiography of coronary bypass graft anastomoses. , 2011, The Journal of thoracic and cardiovascular surgery.

[19]  R. Chang,et al.  Tumor detection in automated breast ultrasound images using quantitative tissue clustering. , 2014, Medical physics.

[20]  I. Jolliffe Principal Component Analysis , 2002 .