Inguinal hernia repair using a synthetic long-term resorbable mesh: results from a 3-year prospective safety and performance study

PurposeConventional meshes for hernia repair and abdominal wall reinforcement are usually made from polypropylene, polyester or other synthetic plastic materials known to promote foreign body reactions and a state of chronic inflammation that may lead to long-term complications. A novel approach is to use long-term resorbable implants like TIGR® Matrix Surgical Mesh. Preclinical studies have shown that this mesh maintains mechanical integrity beyond the point in time where newly formed tissue is capable of carrying the abdominal loads.MethodsThis was a first-in-man, prospective, pilot study performed during 2009, at two sites in Sweden. Forty patients with primary inguinal hernias were enrolled for Lichtenstein repair using TIGR® Matrix Surgical Mesh. The primary endpoint was safety as assessed by monitoring the incidence of adverse events and serious adverse events (SAEs) both related and unrelated to the mesh. The secondary endpoint was pain or discomfort. Visual Analogue Scale (VAS) 0–10 and Inguinal Pain Questionnaire were used for scoring pain and discomfort. Included patients have been followed for 36 months using ultrasound in combination with clinical examination.ResultsAll patients followed a normal early postoperative course. After 12 months no SAEs were reported. None of the patients with an isolated lateral inguinal hernia (LIH) had developed a recurrence but 4 (44 %) with medial and 4 (33 %) with combined hernias had recurred at 36-month follow-up. After 3-year follow-up none of the patients with LIH reported pain in the VAS-form and none of those patients could feel the sensation of a mesh in their groin. In the total study population 5 (16 %) patients experienced chronic pain in the form of mild sporadic pain and 3 (9.7 %) patients could feel the sensation of a mesh in their groin.ConclusionThe use of a synthetic long-term resorbable mesh (TIGR® Matrix Surgical Mesh) in Lichtenstein repair was found to be safe, without recurrences, and promising regarding pain/discomfort at 3-year follow-up in patients with LIH. However, patients with medial and combined inguinal hernias had high recurrence rates.

[1]  E. Aytaç,et al.  Risk of infection and hernia recurrence for patients undergoing ventral hernia repair with non-absorbable or biological mesh during open bowel procedures , 2013, Techniques in Coloproctology.

[2]  G. Tzovaras,et al.  Open inguinal hernia repair with the use of polyglycolic acid/trimethylene carbonate absorbable mesh: a critical update of the long-term results , 2013, Hernia.

[3]  U. Gunnarsson,et al.  Validation of an Inguinal Pain Questionnaire for assessment of chronic pain after groin hernia repair , 2007, The British journal of surgery.

[4]  U Klinge,et al.  Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall. , 2003, The European journal of surgery = Acta chirurgica.

[5]  M. Franz,et al.  The biology of hernias and the abdominal wall , 2006, Hernia.

[6]  R. Bleichrodt,et al.  Chronic pain after mesh repair of inguinal hernia: a systematic review. , 2007, American journal of surgery.

[7]  A. J. Rodrigues Júnior,et al.  Quantitative analysis of collagen and elastic fibers in the transversalis fascia in direct and indirect inguinal hernia. , 2002, Revista do Hospital das Clinicas.

[8]  G. Pascual,et al.  TGF‐β1 overexpression in the transversalis fascia of patients with direct inguinal hernia , 2007, European journal of clinical investigation.

[9]  L. Strobbe,et al.  Randomized trial comparing the Prolene® Hernia System, mesh plug repair and Lichtenstein method for open inguinal hernia repair , 2005, The British journal of surgery.

[10]  P. O’Dwyer,et al.  Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair , 2005, The British journal of surgery.

[11]  W. M. Eccles,et al.  Hernia , 1901, The Hospital.

[12]  K. Bland Randomized Clinical Trial Comparing the Prolene® Hernia System, Mesh Plug Repair and Lichtenstein Method for Open Inguinal Hernia Repair , 2006 .

[13]  G. Sakorafas,et al.  Open tension free repair of inguinal hernias; the Lichtenstein technique , 2001, BMC surgery.

[14]  S. Hazinedaroglu,et al.  Comparison of the plasma and hernia sac tissue copper levels in direct and indirect inguinal hernia patients , 2007, Biological Trace Element Research.

[15]  Ivan Martin,et al.  The FASEB Journal express article 10.1096/fj.01-0656fje. Published online December 28, 2001. Cell differentiation by mechanical stress , 2022 .

[16]  B. Klosterhalfen,et al.  Expression of the Extracellular Matrix Proteins Collagen I, Collagen III and Fibronectin and Matrix Metalloproteinase-1 and -13 in the Skin of Patients with Inguinal Hernia , 1999, European Surgical Research.

[17]  D. Dhar,et al.  FK506 with Portal Decompression Exerts Beneficial Effects following Extended Hepatectomy in Dogs , 1999, European Surgical Research.

[18]  J. Deprest,et al.  Hernia repair: the search for ideal meshes , 2009, Hernia.

[19]  S. Badylak,et al.  Intestine submucosa and polypropylene mesh for abdominal wall repair in dogs. , 1996, The Journal of surgical research.

[20]  I. Abci,et al.  Role of TIMP-2 in Fascia Transversalis on Development of Inguinal Hernias , 2005, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[21]  S. Bringman,et al.  Three‐year results of a randomized clinical trial of lightweight or standard polypropylene mesh in Lichtenstein repair of primary inguinal hernia , 2006, The British journal of surgery.

[22]  C. Chu The effect of pH on the in vitro degradation of poly(glycolide lactide) copolymer absorbable sutures. , 1982, Journal of biomedical materials research.

[23]  B. Matthews,et al.  Normal intraabdominal pressure in healthy adults. , 2005, The Journal of surgical research.

[24]  P. O’Dwyer,et al.  Outcome of patients with severe chronic pain following repair of groin hernia , 2002, The British journal of surgery.

[25]  D. Lorenz,et al.  Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair , 2004, The British journal of surgery.

[26]  J. Loeser,et al.  Bonica's Management of Pain , 2001 .

[27]  P. Amid Radiologic images of meshoma: a new phenomenon causing chronic pain after prosthetic repair of abdominal wall hernias. , 2004, Archives of surgery.

[28]  P. Frost,et al.  Impact of occupational mechanical exposures on risk of lateral and medial inguinal hernia requiring surgical repair , 2012, Occupational and Environmental Medicine.

[29]  G. Clermont,et al.  Three-year results from a preclinical implantation study of a long-term resorbable surgical mesh with time-dependent mechanical characteristics , 2011, Hernia.

[30]  J. Mehnert,et al.  INDIRECT RECURRENCES OF INGUINAL HERNIAS. , 1963, American journal of surgery.

[31]  D. Kelly,et al.  Mechano-regulation of mesenchymal stem cell differentiation and collagen organisation during skeletal tissue repair , 2010, Biomechanics and modeling in mechanobiology.

[32]  I. Lichtenstein,et al.  Open "tension-free" repair of inguinal hernias: the Lichtenstein technique. , 1996, The European journal of surgery = Acta chirurgica.

[33]  S. Houterman,et al.  Evaluating postherniorrhaphy groin pain: Visual Analogue or Verbal Rating Scale? , 2008, Hernia.