A portable, shock-proof, surface-heated droplet PCR system for Escherichia coli detection.

A novel polymerase chain reaction (PCR) device was developed that uses wire-guided droplet manipulation (WDM) to guide a droplet over three different heating chambers. After PCR amplification, end-point detection is achieved using a smartphone-based fluorescence microscope. The device was tested for identification of the 16S rRNA gene V3 hypervariable region from Escherichia coli genomic DNA. The lower limit of detection was 10(3) genome copies per sample. The device is portable with smartphone-based end-point detection and provides the assay results quickly (15 min for a 30-cycle amplification) and accurately. The system is also shock and vibration resistant, due to the multiple points of contact between the droplet and the thermocouple and the Teflon film on the heater surfaces. The thermocouple also provides real-time droplet temperature feedback to ensure it reaches the set temperature before moving to the next chamber/step in PCR. The device is equipped to use either silicone oil or coconut oil. Coconut oil provides additional portability and ease of transportation by eliminating spilling because its high melting temperature means it is solid at room temperature.

[1]  H. Ellerbrok,et al.  Rapid and sensitive identification of pathogenic and apathogenic Bacillus anthracis by real-time PCR. , 2002, FEMS microbiology letters.

[2]  Da Xing,et al.  Integrated microfluidic reverse transcription-polymerase chain reaction for rapid detection of food- or waterborne pathogenic rotavirus. , 2011, Analytical biochemistry.

[3]  Jeong-Yeol Yoon,et al.  Microfluidic immunosensor with integrated liquid core waveguides for sensitive Mie scattering detection of avian influenza antigens in a real biological matrix , 2010, Analytical and bioanalytical chemistry.

[4]  P. Domínguez-García,et al.  Discrete magnetic microfluidics , 2006 .

[5]  Michael G. Roper,et al.  A fully integrated microfluidic genetic analysis system with sample-in–answer-out capability , 2006, Proceedings of the National Academy of Sciences.

[6]  M. Baker Digital PCR hits its stride , 2012, Nature Methods.

[7]  Jr-Lung Lin,et al.  Integrated polymerase chain reaction chips utilizing digital microfluidics , 2006, Biomedical microdevices.

[8]  David J. You,et al.  Droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling for simpler and faster PCR assay using wire-guided manipulations , 2012, Journal of biological engineering.

[9]  K. Mullis,et al.  Specific enzymatic amplification of DNA in vitro: the polymerase chain reaction. , 1986, Cold Spring Harbor symposia on quantitative biology.

[10]  P. Cane,et al.  Quantitation of hepatitis B lamivudine resistant mutants by real-time amplification refractory mutation system PCR. , 2004, Journal of hepatology.

[11]  R. Tauxe,et al.  The epidemiology of infections caused by Escherichia coli O157:H7, other enterohemorrhagic E. coli, and the associated hemolytic uremic syndrome. , 1991, Epidemiologic reviews.

[12]  Gwo-Bin Lee,et al.  An integrated microfluidic chip for DNA/RNA amplification, electrophoresis separation and on‐line optical detection , 2006, Electrophoresis.

[13]  Min Jun Kim,et al.  Gold nanoparticles for one step DNA extraction and real-time PCR of pathogens in a single chamber. , 2008, Lab on a chip.

[14]  S. Cho,et al.  Creating, transporting, cutting, and merging liquid droplets by electrowetting-based actuation for digital microfluidic circuits , 2003 .

[15]  M. McClelland,et al.  Polymorphisms generated by arbitrarily primed PCR in the mouse: application to strain identification and genetic mapping. , 1991, Nucleic acids research.

[16]  J. Welsh,et al.  Fingerprinting genomes using PCR with arbitrary primers. , 1990, Nucleic acids research.

[17]  Zhi Zhu,et al.  Single-molecule emulsion PCR in microfluidic droplets , 2012, Analytical and Bioanalytical Chemistry.

[18]  Jeong-Yeol Yoon,et al.  Field-deployable and near-real-time optical microfluidic biosensors for single-oocyst-level detection of Cryptosporidium parvum from field water samples. , 2012, Journal of environmental monitoring : JEM.

[19]  Jeong-Yeol Yoon,et al.  Lab-on-a-Chip Pathogen Sensors for Food Safety , 2012, Sensors.

[20]  Stephen A Bustin,et al.  Reliability of real-time reverse-transcription PCR in clinical diagnostics: gold standard or substandard? , 2009, Expert review of molecular diagnostics.

[21]  Massimo Castagnola,et al.  PCR experion automated electrophoresis system to detect Listeria monocytogenes in foods. , 2009, Journal of separation science.

[22]  Tetsuo Ohashi,et al.  A simple device using magnetic transportation for droplet-based PCR , 2007, Biomedical microdevices.

[23]  Tu San Park,et al.  Paper microfluidic extraction and direct smartphone-based identification of pathogenic nucleic acids from field and clinical samples , 2014 .

[24]  J. Trevors,et al.  Application of real-time quantitative PCR for the detection of selected bacterial pathogens during municipal wastewater treatment. , 2007, The Science of the total environment.

[25]  S. Edberg,et al.  Escherichia coli: the best biological drinking water indicator for public health protection , 2000, Symposium series.

[26]  Suhyeon Kim,et al.  Microchip-based one step DNA extraction and real-time PCR in one chamber for rapid pathogen identification. , 2006, Lab on a chip.

[27]  Jeong-Yeol Yoon,et al.  Single-pipetting microfluidic assay device for rapid detection of Salmonella from poultry package. , 2013, Biosensors & bioelectronics.

[28]  María-Isabel Rocha-Gaso,et al.  Surface Generated Acoustic Wave Biosensors for the Detection of Pathogens: A Review , 2009, Sensors.

[29]  Jeong-Yeol Yoon,et al.  Single cell level detection of Escherichia coli in microfluidic device. , 2008, Biosensors & bioelectronics.

[30]  Sascha Sauer,et al.  Mass spectrometry tools for the classification and identification of bacteria , 2010, Nature Reviews Microbiology.

[31]  Tu San Park,et al.  Enhanced nucleic acid amplification with blood in situ by wire-guided droplet manipulation (WDM). , 2014, Biosensors & bioelectronics.