Artifacts Removal in EEG Signal using Adaptive Neuro Fuzzy Inference System

In this paper, we propose a hybrid soft computing technique called adaptive neuro-fuzzy inference system (ANFIS) to estimate the interference and to separate the electroencephalogram (EEG) signal from its electrooculogram (EOG), electrocardiogram (ECG) and electromyogram (EMG) artifacts. This paper shows that the proposed method successfully removes the artifacts and extracts the desired EEG signal

[1]  S. Vorobyov APPLICATION OF ICA FOR AUTOMATIC NOISE AND INTERFERENCE CANCELLATION IN MULTISENSORY BIOMEDICAL SIGNALS , 2000 .

[2]  E Donchin,et al.  A new method for off-line removal of ocular artifact. , 1983, Electroencephalography and clinical neurophysiology.

[3]  Stanly Johnson Jeyaraj,et al.  Fetal ECG Extraction using Softcomputing Technique , 2006 .

[4]  H. Moldofsky,et al.  A spectral method for removing eye movement artifacts from the EEG. , 1978, Electroencephalography and clinical neurophysiology.

[5]  W. Blume,et al.  Atlas of Adult Electroencephalography , 1995 .

[6]  J. Kenemans,et al.  Removal of the ocular artifact from the EEG: a comparison of time and frequency domain methods with simulated and real data. , 1991, Psychophysiology.

[7]  Andrzej Cichocki,et al.  Blind noise reduction for multisensory signals using ICA and subspace filtering, with application to EEG analysis , 2002, Biological Cybernetics.

[8]  D. Broverman,et al.  EEG response to photic stimulation as a function of cognitive style. , 1969, Electroencephalography and clinical neurophysiology.

[9]  Martin J. McKeown,et al.  Removing electroencephalographic artifacts: comparison between ICA and PCA , 1998, Neural Networks for Signal Processing VIII. Proceedings of the 1998 IEEE Signal Processing Society Workshop (Cat. No.98TH8378).

[10]  Stephen J. Roberts,et al.  ARTEFACT DETECTION IN SLEEP EEG BY THE USE OF KALMAN FILTERING , 2007 .

[11]  Z J Koles,et al.  The quantitative extraction and topographic mapping of the abnormal components in the clinical EEG. , 1991, Electroencephalography and clinical neurophysiology.

[12]  T. Sejnowski,et al.  Removing electroencephalographic artifacts by blind source separation. , 2000, Psychophysiology.

[13]  Kenneth E. Barner,et al.  An interference cancellation algorithm for noninvasive extraction of transabdominal fetal electroencephalogram (TaFEEG) , 2004, IEEE Transactions on Biomedical Engineering.

[14]  Witold Kinsner,et al.  Separation performance of ICA on simulated EEG and ECG signals contaminated by noise , 2002, IEEE CCECE2002. Canadian Conference on Electrical and Computer Engineering. Conference Proceedings (Cat. No.02CH37373).

[15]  Jyh-Shing Roger Jang,et al.  ANFIS: adaptive-network-based fuzzy inference system , 1993, IEEE Trans. Syst. Man Cybern..

[16]  T. Gasser,et al.  Correction of EOG artifacts in event-related potentials of the EEG: aspects of reliability and validity. , 1982, Psychophysiology.

[17]  D. Overton,et al.  Distribution of eye movement and eyeblink potentials over the scalp. , 1969, Electroencephalography and clinical neurophysiology.

[18]  T. Sejnowski,et al.  Removal of eye activity artifacts from visual event-related potentials in normal and clinical subjects , 2000, Clinical Neurophysiology.