Dynamic study of oxidative stress in renal dialysis patients based on breath ethane measured by optical spectroscopy

The application of optical spectroscopy for rapid accurate measurement of breath biomarkers has opened up new possibilities for monitoring and diagnostics in recent years. Here, we report on how our recent advances in optical detection of ethane have enabled us to record dynamic breath ethane patterns for patients undergoing kidney dialysis. Ethane is well established as a breath biomarker for free radical induced cell degradation. Moreover, renal dialysis is known to induce such oxidative attack, and our measurements may offer insight into the nature of this assault. Specifically, we have discovered that patients undergo significant breath ethane elevation at the beginning of each dialysis session. We have found an inverse relationship between the magnitude of this effect and number of months patients have been receiving treatment. We comment on how further refinements of our technology will allow a more detailed evaluation of the ethane elevation effect and ultimately lead to the assessment of potential interventions.

[1]  P. Aadahl,et al.  A Validated Method for Rapid Analysis of Ethane in Breath and its Application in Kinetic Studies in Human Volunteers , 2003, Free radical research.

[2]  G B Bulkley,et al.  Ethane: a marker of lipid peroxidation during cardiopulmonary bypass in humans. , 1999, Free radical biology & medicine.

[3]  T. Risby,et al.  Clinical application of breath biomarkers of oxidative stress status. , 1999, Free radical biology & medicine.

[4]  B. Descamps-Latscha,et al.  Dialysis‐Induced Oxidative Stress: Biological Aspects, Clinical Consequences, and Therapy , 2001, Seminars in dialysis.

[5]  M. Lieberman,et al.  Ethane Evolution: A New Index of Lipid Peroxidation , 1974, Science.

[6]  R. Cataneo,et al.  Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study , 1999, The Lancet.

[7]  L R Narasimhan,et al.  Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[8]  W. Miekisch,et al.  Diagnostic potential of breath analysis--focus on volatile organic compounds. , 2004, Clinica chimica acta; international journal of clinical chemistry.

[9]  P. Hering,et al.  Real-time monitoring of ethane in human breath using mid-infrared cavity leak-out spectroscopy , 2001 .

[10]  Luke R. Wilson,et al.  InGaAs∕AlAsSb∕InP quantum cascade lasers operating at wavelengths close to 3μm , 2007 .

[11]  K. Mcleish,et al.  Hemodialysis with cellulose membranes primes the neutrophil oxidative burst. , 1995, Artificial organs.

[12]  A. Sevanian,et al.  Oxidative stress during ex vivo hemodialysis of blood is decreased by a novel hemolipodialysis procedure utilizing antioxidants. , 2002, Free radical biology & medicine.

[13]  T. Ozben,et al.  Effect of haemodialysis on the oxidative stress and antioxidants in diabetes mellitus , 2005, Acta Diabetologica.

[14]  Scott E. Bisson,et al.  Photoacoustic trace gas detection of ethane using a continuously tunable, continuous-wave optical parametric oscillator based on periodically poled lithium niobate , 2002 .

[15]  J. Wauters,et al.  Neutrophil oxygen radical production by dialysis membranes. , 1988, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[16]  W. Pryor Measurement of oxidative stress status in humans. , 1993, Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology.

[17]  Z. Massy,et al.  Oxidative stress and haemodialysis: role of inflammation and duration of dialysis treatment. , 2001, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[18]  Graham M. Gibson,et al.  The potential offered by real-time, high-sensitivity monitoring of ethane in breath and some pilot studies using optical spectroscopy , 2005 .

[19]  P. Hering,et al.  Online monitoring of ethane traces in exhaled breath with a difference frequency generation spectrometer , 2006 .

[20]  M J Padgett,et al.  Application of laser spectroscopy for measurement of exhaled ethane in patients with lung cancer. , 2006, Respiratory medicine.

[21]  Magdi H. Yacoub,et al.  Disease Markers in Exhaled Breath , 2002 .

[22]  K. Mcleish,et al.  Oxidant stress in hemodialysis patients: what are the determining factors? , 2003, Artificial organs.

[23]  G. Handelman Current Studies on Oxidant Stress in Dialysis , 2003, Blood Purification.

[24]  C. Kneepkens,et al.  The potential of the hydrocarbon breath test as a measure of lipid peroxidation. , 1994, Free radical biology & medicine.

[25]  C. Ronco,et al.  Oxidant Stress in Hemodialysis , 2000, Nephron.

[26]  S. Mayne,et al.  Antioxidant nutrients and chronic disease: use of biomarkers of exposure and oxidative stress status in epidemiologic research. , 2003, The Journal of nutrition.

[27]  T. Ozben,et al.  Effect of Hemodialysis on the Oxidative Stress and Antioxidants , 2002, Clinical chemistry and laboratory medicine.

[28]  G. Handelman RENAL RESEARCH INSTITUTE SYMPOSIUM: Efforts to Determine the Role of Oxidant Stress in Dialysis Outcomes , 2003, Seminars in dialysis.

[29]  T. Imaizumi,et al.  Hemodialysis impairs endothelial function via oxidative stress: effects of vitamin E-coated dialyzer. , 2000, Circulation.

[30]  R. Ouseph,et al.  Effects of high-flux hemodialysis on oxidant stress. , 2003, Kidney international.

[31]  M J Padgett,et al.  Breath ethane peaks during a single haemodialysis session and is associated with time on dialysis , 2008, Journal of breath research.

[32]  J. Cristol,et al.  Erythropoietin and oxidative stress in haemodialysis: beneficial effects of vitamin E supplementation. , 1997, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[33]  John Tulip,et al.  Pulsed quantum cascade laser-based cavity ring-down spectroscopy for ammonia detection in breath. , 2006, Applied optics.

[34]  J. Allard,et al.  Breath alkanes as a marker of oxidative stress in different clinical conditions. , 2000, Free radical biology & medicine.

[35]  Graham M. Gibson,et al.  Portable optical spectroscopy for accurate analysis of ethane in exhaled breath , 2007 .

[36]  B. Halliwell,et al.  Free radicals in biology and medicine , 1985 .

[37]  S. Banni,et al.  No direct evidence of increased lipid peroxidation in hemodialysis patients. , 1996, Nephron.

[38]  P. Abuja,et al.  Methods for monitoring oxidative stress, lipid peroxidation and oxidation resistance of lipoproteins. , 2001, Clinica chimica acta; international journal of clinical chemistry.

[39]  Claudio Ronco,et al.  Breath ethane in dialysis patients and control subjects. , 2003, Free radical biology & medicine.

[40]  J. Morrow,et al.  Measurement of F(2)-isoprostanes as an index of oxidative stress in vivo. , 2000, Free radical biology & medicine.