Experimental Investigation of the Influence of Moisture on the Bond Behavior of FRP to Concrete Interfaces

The effects of moisture on the initial and long-term bonding behavior of fiber reinforced polymer (FRP) sheets to concrete interfaces have been investigated by means of a two-year experimental exposure program. The research is focused on the effects of (1) moisture at the time of FRP installation, in this paper termed “construction moisture,” consisting of concrete substratum surface moisture and external air moisture; and (2) moisture, in this paper termed “service moisture,” which normally varies throughout the service life of concrete. Concrete beams with FRP bonded to their soffits were prepared. Before bonding, concrete substrates were preconditioned with different moisture contents and treated with different primers. The FRP bonded concrete beams were then cured under different humidity conditions before being subjected to combined wet/dry (WD) and thermal cycling regimes to accelerate the exposure effects. Adhesives with different elastic moduli were used to investigate the long-term durability of ...

[1]  Michael F. Petrou,et al.  The Effect of the Presence of Water on the Durability of Bond between CFRP and Concrete , 2006 .

[2]  Lawrence C. Bank,et al.  Accelerated Test Methods to Determine the Long-Term Behavior of FRP Composite Structures: Environmental Effects , 1995 .

[3]  Hy Leung,et al.  FLEXURAL CAPACITY OF STRENGTHENED CONCRETE BEAM EXPOSED TO DIFFERENT ENVIRONMENTAL CONDITIONS , 2001 .

[4]  Manuel A.G. Silva,et al.  Degradation of bond between FRP and RC beams , 2008 .

[5]  Tamon Ueda,et al.  Development of the Nonlinear Bond Stress-Slip Model of Fiber Reinforced Plastics Sheet-Concrete Interfaces with a Simple Method , 2005 .

[6]  T. Almusallam Load–deflection behavior of RC beams strengthened with GFRP sheets subjected to different environmental conditions , 2006 .

[7]  M. Chajes,et al.  Durability of concrete beams externally reinforced with composite fabrics , 1995 .

[8]  R. Sen,et al.  Durability of Carbon Fiber-Reinforced Polymer/Epoxy/Concrete Bond in Marine Environment , 1999 .

[9]  Cyril J. Lynsdale,et al.  Influence of aggressive exposure conditions on the behaviour of adhesive bonded concrete–GFRP joints , 1998 .

[10]  J. Dai,et al.  A Hybrid Bonding System for Improving the Structural Performance of FRP Flexurally Strengthened Concrete Beams , 2009 .

[11]  Oral Büyüköztürk,et al.  Peel and Shear Fracture Characterization of Debonding in FRP Plated Concrete Affected by Moisture , 2006 .

[12]  Thomas E. Boothby,et al.  Durability Evaluation of Glass Fiber Reinforced-Polymer-Concrete Bonded Interfaces , 2005 .

[13]  Vistasp M. Karbhari,et al.  Investigation of durability and surface preparation associated defect criticality of composites bonded to concrete , 2008 .

[14]  Vistasp M. Karbhari,et al.  Issues related to composite plating and environmental exposure effects on composite-concrete interface in external strengthening , 1997 .

[15]  A Fracture Mechanics Approach for Interface Durability of Bonded FRP to Concrete , 2005, SP-230: 7th International Symposium on Fiber-Reinforced (FRP) Polymer Reinforcement for Concrete Structures.

[16]  Nabil F. Grace,et al.  Durability Evaluation of Carbon Fiber-Reinforced Polymer Strengthened Concrete Beams: Experimental Study and Design , 2005 .

[17]  Baolin Wan,et al.  NUMERICAL SIMULATION OF BOND DETERIORATION BETWEEN CFRP PLATE AND CONCRETE IN MOISTURE ENVIRONMENT , 2006 .

[18]  Houssam Toutanji,et al.  Durability characteristics of concrete beams externally bonded with FRP composite sheets , 1997 .

[19]  J. Dai,et al.  2238 IMPROVING THE LOAD TRANSFER AND EFFECTIVE BOND LENGTH FOR FRP COMPOSITES BONDED TO CONCRETE , 2002 .

[20]  Mark F. Green,et al.  Effect of freeze-thaw cycles on the bond durability between fibre reinforced polymer plate reinforcement and concrete , 2000 .