Application of Electric Resistance Change Method to Damage Detection of CFRP Bolted Joints
暂无分享,去创建一个
Hideo Kobayashi | Akira Todoroki | Yoshinobu Shimamura | Takaomi Inada | Keiko Oda | A. Todoroki | Hideo Kobayashi | Y. Shimamura | K. Oda | Takaomi Inada
[1] Shiv P. Joshi,et al. Damage detection in CFRP by electrical conductivity mapping , 2001 .
[2] T. A. Collings,et al. The strength of bolted joints in multi-directional cfrp laminates , 1977 .
[3] Peter Schwartz,et al. Monitoring bending fatigue in carbon-fibre/epoxy composite strands: a comparison between mechanical and resistance techniques , 2001 .
[4] Hideo Kobayashi,et al. Effects with a matrix crack on monitoring by electrical resistance method , 2004 .
[5] Pedro P. Camanho,et al. Stress analysis and strength prediction of mechanically fastened joints in FRP: A review , 1997 .
[6] K. J. Lodge. The electrical properties of joints in carbon fibre composites , 1982 .
[7] Akira Todoroki,et al. Measurement of orthotropic electric conductance of CFRP laminates and analysis of the effect on delamination monitoring with an electric resistance change method , 2002 .
[8] M. Miyayama,et al. Foreseeing of Fracture in CFGFRP Composites by Measuring Electrical Resistance. , 1992 .
[9] W. J. Quinn,et al. The Effect of Stacking Sequence on the Pin-Bearing Strength in Glass Fibre Reinforced Plastic , 1977 .
[10] Xiaojun Wang,et al. Sensing delamination in a carbon fiber polymer-matrix composite during fatigue by electrical resistance measurement , 1997 .
[11] G. Giraud,et al. In-situ monitoring of damage in CFRP laminates by means of AC and DC measurements , 2001 .
[12] Karl Schulte,et al. Non-destructive testing of FRP by d.c. and a.c. electrical methods , 2001 .
[13] D. Chung,et al. Carbon fiber reinforced concrete for smart structures capable of non-destructive flaw detection , 1993 .
[14] D.D.L. Chung,et al. Interface in mechanically fastened polymer joint, studied by contact electrical resistance measurement , 2000 .
[15] T. A. Collings,et al. On the bearing strengths of cfrp laminates , 1982 .
[16] Karl Schulte,et al. Load and failure analyses of CFRP laminates by means of electrical resistivity measurements , 1989 .
[17] S. Al-Hassani,et al. ELECTRICAL RESISTANCE MEASUREMENT TECHNIQUE FOR DETECTING FAILURE IN CFRP MATERIALS AT HIGH STRAIN RATES , 1994 .
[18] D.D.L. Chung,et al. Carbon‐Fiber‐Reinforced Concrete as an Intrinsically Smart Concrete for Damage Assessment during Dynamic Loading , 1995 .
[19] Effect of Fiber Volume Fraction on Monitoring Delamination of CFRP Laminates with Electric Resistance Change Method , 2004 .
[21] A. Todoroki. Electric Resistance Change Method for Cure/Strain/Damage Monitoring of CFRP Laminates , 2004 .
[22] Akira Todoroki,et al. Delamination monitoring of graphite/epoxy laminated composite plate of electric resistance change method , 2002 .
[23] F. L. Matthews,et al. The strength of bolted joints in glass fibre/epoxy laminates , 1985 .
[24] F. J. Arendts,et al. Electrical crack length measurement and the temperature dependence of the mode I fracture toughness of carbon fibre reinforced plastics , 1993 .
[25] Dae-Cheol Seo,et al. Damage detection of CFRP laminates using electrical resistance measurement and neural network , 1999 .
[26] A. Chateauminois,et al. In situ detection of damage in CFRP laminates by electrical resistance measurements , 1999 .