Adsorptive stripping differential pulse voltammetric determination of venlafaxine and desvenlafaxine employing Nafion–carbon nanotube composite glassy carbon electrode

Abstract A Nafion-carbon nanotube-modified glassy carbon electrode (NAF-CNT-GCE) was developed for the determination of venlafaxine (VF) and desvenlafaxine (DVF). The electrochemical behavior of both these molecules was investigated employing cyclic voltammetry (CV), chronocoulometry (CC), electrochemical impedance spectroscopy (EIS) and adsorptive stripping differential pulse voltammetry (AdSDPV). The surface morphology of the electrodes has been studied by means of scanning electron microscopy (SEM). These studies revealed that the oxidation of VF and DVF is facilitated at NAF-CNT-GCE. After optimization of analytical conditions employing this electrode at pH 7.0 in Britton–Robinson buffer (0.05 M) for VF and pH 5.0 in acetate buffer (0.1 M) for DVF, the peak currents for both the molecules were found to vary linearly with their concentrations in the range of 3.81 × 10−8–6.22 × 10−5 M for VF and 5.33 × 10−8–3.58 × 10−5 M for DVF. The detection limits (S/N = 3) of 1.24 × 10−8 and 2.11 × 10−8 M were obtained for VF and DVF, respectively, using AdSDPV. The prepared modified electrode showed several advantages, such as simple preparation method, high sensitivity, very low detection limits and excellent reproducibility. The proposed method was employed for the determination of VF and DVF in pharmaceutical formulations, urine and blood serum samples.

[1]  B. Kasprzyk-Hordern,et al.  Enantiomeric analysis of drugs of abuse in wastewater by chiral liquid chromatography coupled with tandem mass spectrometry. , 2010, Journal of chromatography. A.

[2]  J. Veuthey,et al.  Therapeutic drug monitoring of seven psychotropic drugs and four metabolites in human plasma by HPLC-MS. , 2009, Journal of pharmaceutical and biomedical analysis.

[3]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[4]  Guobao Xu,et al.  Determination of concentrated hydrogen peroxide at single-walled carbon nanohorn paste electrode , 2008 .

[5]  S. Karna,et al.  Potentiometric stripping analysis of bismuth based on carbon paste electrode modified with cryptand (2.2.1) and multiwalled carbon nanotubes , 2010 .

[6]  Wei Zhang,et al.  Synergistically improved sensitivity for the detection of specific DNA sequences using polyaniline nanofibers and multi-walled carbon nanotubes composites. , 2009, Biosensors & bioelectronics.

[7]  Yuehe Lin,et al.  Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors. , 2003, Journal of the American Chemical Society.

[8]  S. Shahrokhian,et al.  Glassy carbon electrodes modified with a film of nanodiamond-graphite/chitosan: Application to the highly sensitive electrochemical determination of Azathioprine , 2010 .

[9]  F. Anson Innovations in the Study of Adsorbed Reactants by Chronocoulometry. , 1966 .

[10]  Ning Li,et al.  Simultaneous quantification of venlafaxine and O-desmethylvenlafaxine in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[11]  M. Adeli,et al.  Multi-walled carbon nanotubes with immobilised cobalt nanoparticle for modification of glassy carbon electrode: application to sensitive voltammetric determination of thioridazine. , 2009, Biosensors & bioelectronics.

[12]  Alain Walcarius,et al.  Carbon Paste Electrodes in Facts, Numbers, and Notes: A Review on the Occasion of the 50‐Years Jubilee of Carbon Paste in Electrochemistry and Electroanalysis , 2009 .

[13]  E. McFarland,et al.  Investigation of the enhanced signals from cations and dopamine in electrochemical sensors coated with Nafion , 2009 .

[14]  Pradeep Mathur,et al.  Biomimetic sensor for certain phenols employing a copper(II) complex. , 2010, Analytical chemistry.

[15]  Yang Shu,et al.  Selective extraction/isolation of hemoglobin with ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate (BtmsimPF6). , 2008, Talanta.

[16]  A. Srivastava,et al.  Simultaneous voltammetric determination of acetaminophen, aspirin and caffeine using an in situ surfactant-modified multiwalled carbon nanotube paste electrode , 2010 .

[17]  A. Gómez-Caballero,et al.  Development of a stir bar sorptive extraction based HPLC-FLD method for the quantification of serotonin reuptake inhibitors in plasma, urine and brain tissue samples. , 2010, Journal of pharmaceutical and biomedical analysis.

[18]  J. V. Sancho,et al.  Simultaneous determination of acidic, neutral and basic pharmaceuticals in urban wastewater by ultra high-pressure liquid chromatography-tandem mass spectrometry. , 2010, Journal of chromatography. A.

[19]  J. Ahlner,et al.  Stereoselective determination of venlafaxine and its three demethylated metabolites in human plasma and whole blood by liquid chromatography with electrospray tandem mass spectrometric detection and solid phase extraction. , 2010, Journal of pharmaceutical and biomedical analysis.

[20]  H. Karimi-Maleh,et al.  Nanomolar and selective determination of epinephrine in the presence of norepinephrine using carbon paste electrode modified with carbon nanotubes and novel 2-(4-oxo-3-phenyl-3,4-dihydro-quinazolinyl)-N'-phenyl-hydrazinecarbothioamide. , 2008, Analytical chemistry.

[21]  Lei Zhang,et al.  Electrochemical synthesis of belt-like polyaniline network on p-phenylenediamine functionalized glassy carbon electrode and its use for the direct electrochemistry of horse heart cytochrome c , 2010 .

[22]  Lanlan Yu,et al.  Nafion/multi-wall carbon nanotubes composite film coated glassy carbon electrode for sensitive determination of caffeine , 2010 .

[23]  C. Delerue-Matos,et al.  Adsorptive Stripping Voltammetric Determination of Venlafaxine in Urine with a Mercury Film Microelectrode , 2003 .

[24]  Hong Dai,et al.  An electrochemiluminescent sensor for methamphetamine hydrochloride based on multiwall carbon nanotube/ionic liquid composite electrode. , 2009, Biosensors & bioelectronics.

[25]  Federica Valentini,et al.  Carbon nanotube purification: preparation and characterization of carbon nanotube paste electrodes. , 2003, Analytical chemistry.

[26]  C. Delerue-Matos,et al.  Electrochemical behaviour of Venlafaxine and its determination in pharmaceutical products using square wave voltammetry. , 1999, Farmaco.

[27]  A. Srivastava,et al.  Electrochemical behavior of folic acid at calixarene based chemically modified electrodes and its determination by adsorptive stripping voltammetry , 2007 .

[28]  Zhonghai Zhang,et al.  Rapid amperometric detection of coliforms based on MWNTs/Nafion composite film modified glass carbon electrode. , 2007, Talanta.