Anatomic Evaluation of 3-Dimensional Ultrashort-Echo-Time Bone Maps for PET/MR Attenuation Correction

Ultrashort-echo-time (UTE) sequences have been proposed in the past for MR-based attenuation correction of PET data, because of their ability to image cortical bone. In the present work we assessed the limitations of dual-echo UTE imaging for bone segmentation in head and neck imaging. Sequentially acquired MR and PET/CT clinical data were used for this purpose. Methods: Twenty patients referred for a clinical oncology examination were scanned using a trimodality setup. Among the MR sequences, a dual-echo UTE acquisition of the head was acquired and used to create tissue R2 maps. The different undesired structures present in these maps were identified by an experienced radiologist. Global and local measurements of the overlap between R2-based and CT-based bone masks were computed. Results: UTE R2 maps displayed a nonfunctional relation with CT data. The obtained bone masks showed acceptable overlap with the corresponding CT data, in the case of the skull itself (e.g., 47% mismatch for the parietal region), with decreased performance in the base of the skull and in the neck (e.g., 78% for the maxillary region). Unwanted structures were detected, both anatomic (e.g., sternocleidomastoid, temporal, and masseter muscles) and artifactual (e.g., dental implants and air–tissue interfaces). Conclusion: It is indeed possible to estimate the anatomic location of bone tissue using UTE sequences. However, using pure parametric maps for attenuation correction may lead to bias close to certain anatomic structures and areas of high magnetic field inhomogeneity. More sophisticated approaches are necessary to compensate for these effects.

[1]  J Nucl Med , 2010 .

[2]  N. F. Schwenzer,et al.  Whole-body MR/PET: applications in abdominal imaging , 2012, Abdominal Imaging.

[3]  M E Casey,et al.  Simultaneous reconstruction of emission activity and attenuation coefficient distribution from TOF data, acquired with external transmission source , 2013, Physics in medicine and biology.

[4]  C. Kuhl,et al.  MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence , 2012, The Journal of Nuclear Medicine.

[5]  Gudrun Wagenknecht,et al.  MRI for attenuation correction in PET: methods and challenges , 2012, Magnetic Resonance Materials in Physics, Biology and Medicine.

[6]  G. Delso,et al.  PET–MR imaging using a tri-modality PET/CT–MR system with a dedicated shuttle in clinical routine , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[7]  Til Aach,et al.  Simultaneous Reconstruction of Activity and Attenuation for PET/MR , 2011, IEEE Transactions on Medical Imaging.

[8]  H. Zaidi Is MR-guided attenuation correction a viable option for dual-modality PET/MR imaging? , 2007, Radiology.

[9]  Jean Théberge,et al.  Variable Lung Density Consideration in Attenuation Correction of Whole-Body PET/MRI , 2012, The Journal of Nuclear Medicine.

[10]  G Antoch,et al.  Positron emission tomography (PET) attenuation correction artefacts in PET/CT and PET/MRI. , 2013, The British journal of radiology.

[11]  S. Vandenberghe,et al.  MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences , 2010, Journal of Nuclear Medicine.

[12]  Christoph Palm,et al.  MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[13]  Ciprian Catana,et al.  PET/MRI for Neurologic Applications , 2012, The Journal of Nuclear Medicine.

[14]  Johan Nuyts,et al.  Completion of a truncated attenuation image from the attenuated PET emission data , 2013, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[15]  R. Günther,et al.  Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[16]  Bernhard Schölkopf,et al.  MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration , 2008, Journal of Nuclear Medicine.

[17]  B. Schölkopf,et al.  MR-Based PET attenuation correction for PET/MR imaging. , 2013, Seminars in nuclear medicine.

[18]  Ciprian Catana,et al.  Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype , 2010, The Journal of Nuclear Medicine.

[19]  M. Bronskill,et al.  T1, T2 relaxation and magnetization transfer in tissue at 3T , 2005, Magnetic resonance in medicine.

[20]  Jiang Du,et al.  MR imaging near metal with undersampled 3D radial UTE‐MAVRIC sequences , 2013, Magnetic resonance in medicine.

[21]  Vincent Keereman,et al.  Simultaneous MR-Compatible Emission and Transmission Imaging for PET Using Time-of-Flight Information , 2012, IEEE Transactions on Medical Imaging.

[22]  Weitian Chen,et al.  Imaging near metal with a MAVRIC‐SEMAC hybrid , 2011, Magnetic resonance in medicine.

[23]  Thomas Beyer,et al.  Whole-body hybrid PET/MRI: ready for clinical use? , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[24]  Nassir Navab,et al.  Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data , 2009, Journal of Nuclear Medicine.

[25]  Jiang Du,et al.  Qualitative and quantitative ultrashort‐TE MRI of cortical bone , 2013, NMR in biomedicine.

[26]  Hans Herzog,et al.  Skull segmentation of UTE MR images by probabilistic neural network for attenuation correction in PET/MR , 2013 .

[27]  Koichi Masuda,et al.  Quantitative ultrashort echo time (UTE) MRI of human cortical bone: Correlation with porosity and biomechanical properties , 2012, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[28]  V. Schulz,et al.  Challenges and current methods for attenuation correction in PET/MR , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[29]  Dwight G Nishimura,et al.  Design and analysis of a practical 3D cones trajectory , 2006, Magnetic resonance in medicine.