Modification of pure oxygen absorption equipment for concurrent stripping of carbon dioxide

Abstract The high solubility of carbon dioxide precludes significant desorption within commercial oxygen absorption equipment. This operating characteristic of the equipment limits its application in recirculating water culture systems despite its ability to significantly increase allowable fish loading rates (kg/(L min)). Carbon dioxide (DC) is typically removed by air stripping. This process requires a significant energy input for forced air movement, air heating in cold climates and water pumping. We developed a modification for a spray tower that provides for carbon dioxide desorption as well as oxygen absorption. Elimination of the air-stripping step reduces pumping costs while allowing dissolved nitrogen to drop below saturation concentrations. This latter response provides for an improvement in oxygen absorption efficiency within the spray tower. DC desorption is achieved by directing head-space gases from the spray tower (O 2 , N 2 , CO 2 ) through a sealed packed tower scrubber receiving a 2 N NaOH solution. Carbon dioxide is selectively removed from the gas stream, by chemical reaction, forming the product Na 2 CO 3 . Scrubber off-gas, lean with regard to carbon dioxide but still rich with oxygen, is redirected through the spray tower for further stripping of DC and absorption of oxygen. Make-up NaOH is metered into the scrubbing solution sump on an as needed basis as directed by a feedback control loop programmed to maintain a scrubbing solution pH of 11.4–11.8. The spent NaOH solution is collected, then regenerated for reuse, in a batch process that requires relatively inexpensive hydrated lime (Ca(OH) 2 ). A by-product of the regeneration step is an alkaline filter cake, which may have use in bio-solids stabilization. Given the enhanced gas transfer rates possible with chemical reaction, the required NaOH solution flow rate through the scrubber represents a fraction of the spray tower water flow rate. Further, isolation of the water being treated from the atmosphere (1), allows for an improvement in oxygen absorption efficiency by maintaining DN well below local saturation concentrations (2), minimizes building energy requirements related to heating and ventilation and (3), reduces the potential for pathogen transmittance. We report on the performance of a test scrubber evaluated over a range of NaOH solution temperatures, pH, packing irrigation rates, and gas stream compositions. We also describe our experience with the process in a pilot scale recirculating water (trout) production system.

[1]  C. Boyd,et al.  Modeling the effect of dissolved nitrogen and carbon dioxide on the performance of pure oxygen absorption systems , 1991 .

[2]  S. Basu Active Respiration of Fish in Relation to Ambient Concentrations of Oxygen and Carbon Dioxide , 1959 .

[3]  M. Timmons,et al.  Gas-phase axial dispersion in a spray tower , 1996 .

[4]  C. Boyd,et al.  AERATION SYSTEMS IN AQUACULTURAL , 1989 .

[5]  Clifford W. Randall,et al.  Biological process design for wastewater treatment , 1980 .

[6]  B. Watten,et al.  Aeration and oxygenation , 1994 .

[7]  Michael B. Timmons,et al.  Aquaculture water reuse systems: engineering design and management. , 1994 .

[8]  John Colt,et al.  Applications of pure oxygen in fish culture , 1988 .

[9]  J. Colt Computation of Dissolved Gas Concentrations in Water As Functions of Temperature, Salinity, and Pressure , 1984 .

[10]  J. Colt,et al.  Design of packed columns for degassing , 1984 .

[11]  A. Bergheim,et al.  Solids management and removal for intensive land-based aquaculture production systems , 2000 .

[12]  M. Timmons,et al.  Modeling gas transfer in a spray tower oxygen absorber , 1997 .

[13]  Max Leva,et al.  Gas absorption in beds of rings and saddles , 1955 .

[14]  M. B. Timmons,et al.  Control of pH in closed cycle aquaculture systems , 1994 .

[15]  G. Grace,et al.  Carbon dioxide control , 1994 .

[16]  Dale C. Honeyfield,et al.  Hydraulic characteristics of a rectangular mixed-cell rearing unit , 2000 .

[17]  John Davidson,et al.  Evaluation of full-scale carbon dioxide stripping columns in a coldwater recirculating system , 2003 .

[18]  John Colt,et al.  The performance and design of packed column aeration systems for aquaculture , 1982 .

[19]  C. Boyd,et al.  Feasibility of measuring dissolved carbon dioxide based on head space partial pressures , 2004 .

[20]  F. Yoshida,et al.  Effective interfacial area in packed columns for absorption with chemical reaction , 1963 .

[21]  Theo A. Dillaha,et al.  Modeling gas transfer and biological respiration in a recirculating aquaculture system , 1996 .

[22]  Hiroshi Takeuchi,et al.  GAS ABSORPTION WITH CHEMICAL REACTION IN PACKED COLUMNS , 1968 .

[23]  R. Piedrahita,et al.  Oxygenation and carbon dioxide control in water reuse systems , 2000 .

[24]  B. Watten Design of packed columns for commercial oxygen addition and dissolved nitrogen removal based on effluent criteria , 1990 .

[25]  Octave Levenspiel,et al.  The chemical reactor minibook , 1979 .