Accurate real-time depth control for CP-SSOCT distal sensor based handheld microsurgery tools.
暂无分享,去创建一个
Jin U. Kang | Gyeong Woo Cheon | Yong Huang | Jin U Kang | Peter L Gehlbach | Jaepyeng Cha | P. Gehlbach | Yong Huang | G. Cheon | Jae-Deog Cha
[1] Joseph A. Izatt,et al. PRECLINICAL EVALUATION AND INTRAOPERATIVE HUMAN RETINAL IMAGING WITH A HIGH-RESOLUTION MICROSCOPE-INTEGRATED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE , 2013, Retina.
[2] Kang Zhang,et al. Common-path low-coherence interferometry fiber-optic sensor guided microincision. , 2011, Journal of biomedical optics.
[3] Jin U. Kang,et al. Fiber-optic OCT sensor guided “SMART” micro-forceps for microsurgery , 2013, Biomedical optics express.
[4] R. Ansari,et al. Thickness profiles of retinal layers by optical coherence tomography image segmentation. , 2008, American journal of ophthalmology.
[5] Kang Zhang,et al. Graphics processing unit accelerated non-uniform fast Fourier transform for ultrahigh-speed, real-time Fourier-domain OCT , 2010, Optics express.
[6] Joseph A. Izatt,et al. Unprocessed real-time imaging of vitreoretinal surgical maneuvers using a microscope-integrated spectral-domain optical coherence tomography system , 2012, Graefe's Archive for Clinical and Experimental Ophthalmology.
[7] Russell H. Taylor,et al. Medical robotics in computer-integrated surgery , 2003, IEEE Trans. Robotics Autom..
[8] Jin Ung Kang,et al. Motion compensated fiber-optic confocal microscope based on a common-path optical coherence tomography distance sensor , 2011 .
[9] Jin U. Kang,et al. Motion-compensated hand-held common-path Fourier-domain optical coherence tomography probe for image-guided intervention , 2012, Biomedical optics express.
[10] Cameron N. Riviere,et al. Robotic Compensation of Biological Motion to Enhance Surgical Accuracy , 2006, Proceedings of the IEEE.
[11] Cameron N. Riviere,et al. Modeling and canceling tremor in human-machine interfaces , 1996 .
[12] Yuankai K. Tao,et al. Microscope-integrated intraoperative OCT with electrically tunable focus and heads-up display for imaging of ophthalmic surgical maneuvers. , 2014, Biomedical optics express.
[13] Kang Zhang,et al. A Surface Topology and Motion Compensation System for Microsurgery Guidance and Intervention Based on Common-Path Optical Coherence Tomography , 2009, IEEE Transactions on Biomedical Engineering.
[14] Jin U. Kang,et al. Real-time three-dimensional Fourier-domain optical coherence tomography video image guided microsurgeries. , 2012, Journal of biomedical optics.
[15] Farid Golnaraghi,et al. A Fastening Tool Tracking System Using an IMU and a Position Sensor With Kalman Filters and a Fuzzy Expert System , 2009, IEEE Transactions on Industrial Electronics.
[16] Russell H. Taylor,et al. A Steady-Hand Robotic System for Microsurgical Augmentation , 1999 .
[17] Sina Farsiu,et al. Integration of a spectral domain optical coherence tomography system into a surgical microscope for intraoperative imaging. , 2011, Investigative ophthalmology & visual science.
[18] Nabil Simaan,et al. Evaluation of microsurgical tasks with OCT-guided and/or robot-assisted ophthalmic forceps. , 2015, Biomedical optics express.
[19] M. Patkin. ERGONOMICS APPLIED TO THE PRACTICE OF MICROSURGERY1 , 1977 .
[20] Andrew M. Rollins,et al. Integrative Advances for OCT-Guided Ophthalmic Surgery and Intraoperative OCT: Microscope Integration, Surgical Instrumentation, and Heads-Up Display Surgeon Feedback , 2014, 2015 Conference on Lasers and Electro-Optics (CLEO).
[21] Kang Zhang,et al. Real-time intraoperative 4D full-range FD-OCT based on the dual graphics processing units architecture for microsurgery guidance , 2011, Biomedical optics express.
[22] Russell H. Taylor,et al. Miniature fiber-optic force sensor based on low-coherence Fabry-Pérot interferometry for vitreoretinal microsurgery , 2012, Biomedical optics express.
[23] Cameron N. Riviere,et al. Micron: An Actively Stabilized Handheld Tool for Microsurgery , 2012, IEEE Transactions on Robotics.
[24] Jae-Ho Han,et al. Common-Path Optical Coherence Tomography for Biomedical Imaging and Sensing. , 2010, Journal of the Optical Society of Korea.
[25] Rajani K. Mudi,et al. A robust self-tuning scheme for PI- and PD-type fuzzy controllers , 1999, IEEE Trans. Fuzzy Syst..
[26] Peter K Kaiser,et al. UTILITY OF INTRAOPERATIVE OPTICAL COHERENCE TOMOGRAPHY DURING VITRECTOMY SURGERY FOR VITREOMACULAR TRACTION SYNDROME , 2014, Retina.
[27] Jin U. Kang,et al. Active tremor cancellation by a "smart" handheld vitreoretinal microsurgical tool using swept source optical coherence tomography. , 2012, Optics express.
[28] R. E. Kalman,et al. A New Approach to Linear Filtering and Prediction Problems , 2002 .
[29] Jin-Hui Shen,et al. Miniature real-time intraoperative forward-imaging optical coherence tomography probe. , 2013, Biomedical optics express.
[30] Yi Zheng,et al. Detection of tissue harmonic motion induced by ultrasonic radiation force using pulse-echo ultrasound and kalman filter , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[31] Carmen A Puliafito,et al. Automated detection of retinal layer structures on optical coherence tomography images. , 2005, Optics express.
[32] Cameron N. Riviere,et al. Toward active tremor canceling in handheld microsurgical instruments , 2003, IEEE Trans. Robotics Autom..
[33] Uwe D. Hanebeck,et al. Template matching using fast normalized cross correlation , 2001, SPIE Defense + Commercial Sensing.
[34] Russell H. Taylor,et al. Towards automatic calibration of Fourier-Domain OCT for robot-assisted vitreoretinal surgery , 2010, Optics express.
[35] Shiuh-Ku Weng,et al. Video object tracking using adaptive Kalman filter , 2006, J. Vis. Commun. Image Represent..