In vivo monitoring of glial scar proliferation on chronically implanted neural electrodes by fiber optical coherence tomography

In neural prosthetics and stereotactic neurosurgery, intracortical electrodes are often utilized for delivering therapeutic electrical pulses, and recording neural electrophysiological signals. Unfortunately, neuroinflammation impairs the neuron-electrode-interface by developing a compact glial encapsulation around the implants in long term. At present, analyzing this immune reaction is only feasible with post-mortem histology; currently no means for specific in vivo monitoring exist and most applicable imaging modalities can not provide information in deep brain regions. Optical coherence tomography (OCT) is a well established imaging modality for in vivo studies, providing cellular resolution and up to 1.2 mm imaging depth in brain tissue. A fiber based spectral domain OCT was shown to be capable of minimally invasive brain imaging. In the present study, we propose to use a fiber based spectral domain OCT to monitor the progression of the tissue's immune response through scar encapsulation progress in a rat animal model. A fine fiber catheter was implanted in rat brain together with a flexible polyimide microelectrode in sight both of which acts as a foreign body and induces the brain tissue immune reaction. OCT signals were collected from animals up to 12 weeks after implantation and thus gliotic scarring in vivo monitored for that time. Preliminary data showed a significant enhancement of the OCT backscattering signal during the first 3 weeks after implantation, and increased attenuation factor of the sampled tissue due to the glial scar formation.

[1]  Stuart N. Baker,et al.  Newcastle University Eprints Date Deposited: 23 the Sinusoidal Probe: a New Approach to Improve Electrode Longevity , 2022 .

[2]  Luca Citi,et al.  Restoring Natural Sensory Feedback in Real-Time Bidirectional Hand Prostheses , 2014, Science Translational Medicine.

[3]  D. Edell,et al.  Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex , 1992, IEEE Transactions on Biomedical Engineering.

[4]  M. Block,et al.  Microglia-mediated neurotoxicity: uncovering the molecular mechanisms , 2007, Nature Reviews Neuroscience.

[5]  David C. Martin,et al.  Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film , 2006, Journal of neural engineering.

[6]  Thomas Stieglitz,et al.  In vitro evaluation of the long-term stability of polyimide as a material for neural implants. , 2010, Biomaterials.

[7]  D. Szarowski,et al.  Cerebral Astrocyte Response to Micromachined Silicon Implants , 1999, Experimental Neurology.

[8]  Volker Tronnier,et al.  A simple implantation method for flexible, multisite microelectrodes into rat brains , 2013, Front. Neuroeng..

[9]  K. Horch,et al.  Biocompatibility of silicon-based electrode arrays implanted in feline cortical tissue. , 1993, Journal of biomedical materials research.

[10]  P. Tresco,et al.  Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.

[11]  D. Szarowski,et al.  Brain responses to micro-machined silicon devices , 2003, Brain Research.

[12]  Gereon Hüttmann,et al.  Coronal in vivo forward-imaging of rat brain morphology with an ultra-small optical coherence tomography fiber probe , 2013, Physics in medicine and biology.

[13]  D. Schiffer,et al.  Immunohistochemistry of glial reaction after injury in the rat: Double stainings and markers of cell proliferation , 1993, International Journal of Developmental Neuroscience.

[14]  J. Duker,et al.  Optical coherence tomography of age-related macular degeneration and choroidal neovascularization. , 1996, Ophthalmology.

[15]  J. Fujimoto,et al.  In vivo endoscopic optical biopsy with optical coherence tomography. , 1997, Science.

[16]  Florian Solzbacher,et al.  A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex. , 2010, Biomaterials.

[17]  Shashi K. Murthy,et al.  Bridging the Divide between Neuroprosthetic Design, Tissue Engineering and Neurobiology , 2009, Front. Neuroeng..

[18]  M. Sofroniew,et al.  Reactive Astrocytes in Neural Repair and Protection , 2005, The Neuroscientist : a review journal bringing neurobiology, neurology and psychiatry.

[19]  J. Fujimoto,et al.  Ultrahigh-resolution ophthalmic optical coherence tomography , 2001, Nature Medicine.

[20]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[21]  Ngan B. Doan,et al.  Reactive Astrocytes Protect Tissue and Preserve Function after Spinal Cord Injury , 2004, The Journal of Neuroscience.

[22]  David C. Martin,et al.  Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays , 2005, Experimental Neurology.

[23]  R. Misra,et al.  Biomaterials , 2008 .

[24]  V. Tronnier,et al.  Pallidal stimulation for generalized dystonia. Report of three cases. , 2000, Journal of neurosurgery.

[25]  R V Bellamkonda,et al.  Bioimpedance modeling to monitor astrocytic response to chronically implanted electrodes , 2009, Journal of neural engineering.

[26]  A. Giese,et al.  Time‐domain and spectral‐domain optical coherence tomography in the analysis of brain tumor tissue , 2006, Lasers in surgery and medicine.

[27]  Seong-Gi Kim,et al.  In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes , 2012, Journal of neural engineering.

[28]  M. Weingarten Bridging the divide? Bridges, Israeli-Palestinian Public Health Magazine Ambrogio Manenti, ed. Bimonthly journal. WHO, 2005. No subscription fee. Requests for electronic version to ama@who-health.org or info@who-health.org , 2005, The Lancet.

[29]  Maciej Wojtkowski,et al.  High-speed ultra-high-resolution optical coherence tomography findings in hydroxychloroquine retinopathy. , 2007, Archives of ophthalmology.

[30]  J G Fujimoto,et al.  High-speed, ultra-high-resolution optical coherence tomography of acute macular neuroretinopathy , 2006, British Journal of Ophthalmology.

[31]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[32]  Stanislav Herwik,et al.  Brain-computer interfaces: an overview of the hardware to record neural signals from the cortex. , 2009, Progress in brain research.

[33]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[34]  Kelsey A. Potter,et al.  Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses , 2012, Journal of neural engineering.

[35]  W. Jensen,et al.  In vivo implant mechanics of single-shaft microelectrodes in peripheral nervous tissue , 2007, 2007 3rd International IEEE/EMBS Conference on Neural Engineering.

[36]  Peter Koch,et al.  In vivo Fourier-domain full-field OCT of the human retina with 1.5 million A-lines/s. , 2010, Optics letters.

[37]  Y. Fukuuchi,et al.  Microglia-specific localisation of a novel calcium binding protein, Iba1. , 1998, Brain research. Molecular brain research.