A Retrospective Analysis of Urine Drugs of Abuse Immunoassay True Positive Rates at a National Reference Laboratory.

Urine drug screens are commonly performed to identify drug use or monitor adherence to drug therapy. The purpose of this retrospective study was to evaluate the true positive and false positive rates of one of our in-house urine drug screen panels. The urine drugs of abuse panel studied consists of screening by immunoassay then positive immunoassay results were confirmed by mass spectrometry. Reagents from Syva and Microgenics were used for the immunoassay screen. The screen was performed on a Beckman AU5810 random access automated clinical analyzer. The percent of true positives for each immunoassay was determined. Agreement with previously validated GC-MS or LC-MS-MS confirmatory methods was also evaluated. There were 8,825 de-identified screening results for each of the drugs in the panel, except for alcohol (N = 2,296). The percent of samples that screened positive were: 10.0% for amphetamine/methamphetamine/3,4-methylenedioxy-methamphetamine (MDMA), 12.8% for benzodiazepines, 43.7% for opiates (including oxycodone) and 20.3% for tetrahydrocannabinol (THC). The false positive rate for amphetamine/methamphetamine was ∼14%, ∼34% for opiates (excluding oxycodone), 25% for propoxyphene and 100% for phencyclidine and MDMA immunoassays. Based on the results from this retrospective study, the true positive rate for THC drug use among adults were similar to the rate of illicit drug use in young adults from the 2013 National Survey; however, our positivity rate for cocaine was higher than the National Survey.

[1]  M. Huestis,et al.  One Hundred False-Positive Amphetamine Specimens Characterized by Liquid Chromatography Time-of-Flight Mass Spectrometry. , 2015, Journal of Analytical Toxicology.

[2]  J. Price A Trend Analysis of Laboratory Positive Propoxyphene Workplace Urine Drug Screens Before and After the Product Recall , 2015, Journal of addiction medicine.

[3]  Octavia M Peck Palmer,et al.  Ranitidine interference with standard amphetamine immunoassay. , 2015, Clinica chimica acta; international journal of clinical chemistry.

[4]  Robert L Fitzgerald,et al.  False-positive interferences of common urine drug screen immunoassays: a review. , 2014, Journal of analytical toxicology.

[5]  M. J. Rumpler Quantitative analysis of 11-nor-9-carboxy-tetrahydrocannbinol (THC-COOH) in urine by LC-MS/MS following a simple filtration. , 2014, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[6]  B. Greijdanus,et al.  Fast and Highly Selective LC-MS/MS Screening for THC and 16 Other Abused Drugs and Metabolites in Human Hair to Monitor Patients for Drug Abuse , 2014, Therapeutic drug monitoring.

[7]  B. Greijdanus,et al.  Application of Sweat Patch Screening for 16 Drugs and Metabolites Using a Fast and Highly Selective LC-MS/MS Method , 2013, Therapeutic drug monitoring.

[8]  A. Wasan,et al.  Optimizing urine drug testing for monitoring medication compliance in pain management. , 2013, Pain medicine.

[9]  A. Rengarajan,et al.  How often do false-positive phencyclidine urine screens occur with use of common medications? , 2013, Clinical toxicology.

[10]  R. Heltsley,et al.  Urine drug testing of chronic pain patients. V. Prevalence of propoxyphene following its withdrawal from the United States market. , 2013, Journal of analytical toxicology.

[11]  J. A. Bourland,et al.  Cross-reactivity of tapentadol specimens with DRI methadone enzyme immunoassay. , 2012, Journal of analytical toxicology.

[12]  Y. Kaplan,et al.  False-positive amphetamine/ecstasy (MDMA/3,4-methylenedioxymethamphetamine) (CEDIA) and ecstasy (MDMA/3,4-methylenedioxymethamphetamine) (DRI) test results with fenofibrate. , 2012, Therapeutic drug monitoring.

[13]  G. McMillin,et al.  Sensitive UPLC-MS-MS assay for 21 benzodiazepine drugs and metabolites, zolpidem and zopiclone in serum or plasma. , 2012, Journal of analytical toxicology.

[14]  A. Pesce,et al.  Therapeutic monitoring of benzodiazepines in the management of pain: current limitations of point of care immunoassays suggest testing by mass spectrometry to assure accuracy and improve patient safety. , 2012, Clinica chimica acta; international journal of clinical chemistry.

[15]  D. Murry,et al.  Drug Testing in the Workplace , 2012, Pharmacotherapy.

[16]  A. Burton,et al.  Urine drug testing: current recommendations and best practices. , 2012, Pain physician.

[17]  A. Wu,et al.  False-positive urine phencyclidine immunoassay screen result caused by interference by tramadol and its metabolites. , 2012, Annals of emergency medicine.

[18]  Robert A Middleberg,et al.  Quantitation of amphetamine-type stimulants by LC-MS/MS. , 2012, Methods in molecular biology.

[19]  S. Baker,et al.  A review of the methods, interpretation, and limitations of the urine drug screen. , 2011, Orthopedics.

[20]  J. Baron,et al.  The trazodone metabolite meta-chlorophenylpiperazine can cause false-positive urine amphetamine immunoassay results. , 2011, Journal of analytical toxicology.

[21]  H. Walls,et al.  Crossreactivity of Bupropion Metabolite With Enzyme-Linked Immunosorbent Assays Designed to Detect Amphetamine in Urine , 2011, Therapeutic drug monitoring.

[22]  L. Manchikanti,et al.  Comparative evaluation of the accuracy of benzodiazepine testing in chronic pain patients utilizing immunoassay with liquid chromatography tandem mass spectrometry (LC/MS/MS) of urine drug testing. , 2011, Pain physician.

[23]  J. Magluilo,et al.  Dimethylamylamine: a drug causing positive immunoassay results for amphetamines. , 2011, Journal of analytical toxicology.

[24]  L. Manchikanti,et al.  Urine drug testing in chronic pain. , 2011, Pain physician.

[25]  A. Muzyk,et al.  Interferences With Urine Drug Screens , 2011, Journal of pharmacy practice.

[26]  M. Scott,et al.  Frequency of False Positive Amphetamine Screens due to Bupropion Using the Syva Emit II Immunoassay , 2011, Journal of Medical Toxicology.

[27]  Q. Shafiq,et al.  Urine opiate screening: false-positive result with levofloxacin , 2010, Canadian Medical Association Journal.

[28]  Peter L Tenore,et al.  Advanced Urine Toxicology Testing , 2010, Journal of addictive diseases.

[29]  K. Farmer,et al.  Commonly prescribed medications and potential false-positive urine drug screens. , 2010, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[30]  G. McMillin,et al.  LC-MS/MS analysis of 13 benzodiazepines and metabolites in urine, serum, plasma, and meconium. , 2010, Methods in molecular biology.

[31]  Vincent P Villena Beating the system: a study of a creatinine assay and its efficacy in authenticating human urine specimens. , 2010, Journal of analytical toxicology.

[32]  R. Heltsley,et al.  Urine drug testing of chronic pain patients. II. Prevalence patterns of prescription opiates and metabolites. , 2010, Journal of analytical toxicology.

[33]  A. Pesce,et al.  Unstable propoxyphene metabolite excreted in human urine is detected by liquid chromatography-tandem mass spectrometry. , 2009, Journal of analytical toxicology.

[34]  E. Cone,et al.  Urine Toxicology Testing in Chronic Pain Management , 2009, Postgraduate medicine.

[35]  A. Jenkins,et al.  Cross-reactivity of naloxone with oxycodone immunoassays: implications for individuals taking Suboxone. , 2009, Clinical chemistry.

[36]  Agostinho Santos,et al.  GC determination of acetone, acetaldehyde, ethanol, and methanol in biological matrices and cell culture. , 2009, Journal of chromatographic science.

[37]  Kelly C. Lee,et al.  Urine drug screening: practical guide for clinicians. , 2008, Mayo Clinic proceedings.

[38]  A. Dasgupta The effects of adulterants and selected ingested compounds on drugs-of-abuse testing in urine. , 2007, American journal of clinical pathology.

[39]  R. Weiss,et al.  Is this urine really negative? A systematic review of tampering methods in urine drug screening and testing. , 2007, Journal of substance abuse treatment.

[40]  T. Skripuletz,et al.  Bupropion Interference With Immunoassays for Amphetamines and LSD , 2007, Therapeutic drug monitoring.

[41]  G. McMillin,et al.  Simultaneous determination of codeine, morphine, hydrocodone, hydromorphone, oxycodone, and 6-acetylmorphine in urine, serum, plasma, whole blood, and meconium by LC-MS-MS. , 2007, Journal of analytical toxicology.

[42]  A. Zebelman,et al.  Clinical inquiries. What common substances can cause false positives on urine screens for drugs of abuse? , 2006, The Journal of family practice.

[43]  Amadeo J Pesce,et al.  Urine drug screening in the medical setting. , 2002, Clinica chimica acta; international journal of clinical chemistry.

[44]  J. Valentine,et al.  Identification of urinary benzodiazepines and their metabolites: comparison of automated HPLC and GC-MS after immunoassay screening of clinical specimens. , 1996, Journal of analytical toxicology.

[45]  S. Mulé,et al.  Confirmation and quantitation of barbiturates in human urine by gas chromatography/mass spectrometry. , 1989, Journal of analytical toxicology.

[46]  R. W. Taylor,et al.  Simultaneous identification of cocaine and benzoylecgonine using solid phase extraction and gas chromatography/mass spectrometry. , 1987, Journal of analytical toxicology.