Cochlear pathology. Hazards of long-term implants.

There is increasingly diverse evidence that multichannel intrascalar or modiolar implants can cause long-term changes in cochlear structure. Experimental studies show that nerve-cell loss and osteogenesis are related to electrical stimulation. Low charge densities may limit such intracochlear changes. Middle-ear stimulation presents an alternative to the intracochlear implant, although its degree of effectiveness is not well characterized. Monitoring electrically produced auditory brain-stem responses may help detect progressive pathologic changes occurring in the implanted cochlea.

[1]  S. Walsh,et al.  Chronic electrical stimulation of auditory nerve in cat: Physiological and histological results , 1982, Hearing Research.

[2]  Electrical Stimulation of the Auditory Nerve in Cats , 1979, The Annals of otology, rhinology, and laryngology.

[3]  R. Schindler,et al.  The cochlear histopathology of chronic intracochlear implantation , 1976, The Journal of Laryngology & Otology.

[4]  D Sutton,et al.  Relation of psychophysical data to histopathology in monkeys with cochlear implants. , 1981, Acta oto-laryngologica.

[5]  D. Webster,et al.  Multipolar spiral ganglion neurons following organ of corti loss , 1982, Brain Research.

[6]  Molly Webster,et al.  Spiral ganglion neuron loss following organ of corti loss: A quantitative study , 1981, Brain Research.

[7]  D Sutton,et al.  Comparison of Cochlear Histopathology following Two Implant Designs for Use in Scala Tympani , 1980, The Annals of otology, rhinology & laryngology. Supplement.

[8]  G P Clarke,et al.  External electrical stimulation of the cochlea: clinical, psychophysical, speech-perceptual and histological findings. , 1979, British journal of audiology.

[9]  K Kawamoto,et al.  Ultrastructural changes of the nerve elements following disruption of the organ of Corti. II. Nerve elements outside the organ of Corti. , 1979, Acta oto-laryngologica.

[10]  G M Clark,et al.  An evaluation of per-scalar cochlear electrode implantation techniques , 1977, The Journal of Laryngology & Otology.

[11]  F B Simmons,et al.  Permanent intracochlear electrodes in cats, tissue tolerance and cochlear microphonics. , 1967, The Laryngoscope.

[12]  Michael C. Vivion,et al.  Deaf animal models for studies of a multichannel cochlear prosthesis , 1982, Hearing Research.

[13]  W. House,et al.  Symposium: Cochlear implant, 1978—fact or supposition. Bilateral cochlear implants: Histological findings in a pair of temporal bones , 1979, The Laryngoscope.

[14]  J. Jacobs,et al.  Electrical stimulation of osteogenesis in pathological osseous defects. , 1976, Journal of periodontology.

[15]  L. Duckert Morphological changes in the normal and neomycin‐perfused guinea pig cochlea following chronic prosthetic implantation. , 1983, The Laryngoscope.

[16]  J. Klein,et al.  Panel IV Microbiology, Immunology, Biochemistry and Vaccination , 1980 .

[17]  L. Duckert,et al.  Acute Morphological Changes in Guinea Pig Cochlea following Electrical Stimulation , 1982, The Annals of otology, rhinology, and laryngology.