Subpixel position measurement using 1D, 2D and 3D centroid algorithms with emphasis on applications in confocal microscopy

The accuracy with which centroid algorithms in 1D, 2D and 3D can estimate an object's position has been investigated. Three factors that can influence the method's accuracy have been investigated: systematic error of the algorithm, influence of photon noise and the influence of perturbations such as scanning nonlinearity. The variation of the accuracy with parameters that are relevant for confocal microscopy, such as object diameter and photon noise/pixel, has been considered. Theory and simulations presented show that the variation of the accuracy with respect to such parameters can differ drastically between the 1D, 2D and 3D cases. Experiments performed using microspheres show that the magnitudes of the three types of error can be approximately the same under normal operating conditions and that it is therefore necessary to take all three into account when assessing the total error.

[1]  Anders Liljeborg Digital Position Encoding Of Galvanometer Scanner In A Laser Microscope , 1988 .

[2]  M. Abramowitz,et al.  Handbook of Mathematical Functions With Formulas, Graphs and Mathematical Tables (National Bureau of Standards Applied Mathematics Series No. 55) , 1965 .

[3]  W. Reeves Royal Microscopical Society , 1873, Nature.

[4]  Milton Abramowitz,et al.  Handbook of Mathematical Functions with Formulas, Graphs, and Mathematical Tables , 1964 .

[5]  J. G. Timothy,et al.  Centroid position measurements and subpixel sensitivity variations with the MAMA detector. , 1989, Applied optics.

[6]  Geoff West,et al.  A survey and examination of subpixel measurement techniques , 1990, ISPRS International Conference on Computer Vision and Remote Sensing.

[7]  Scott E. Bulau,et al.  Simulations Of Various Centroiding Algorithms , 1986, Astronomical Telescopes and Instrumentation.

[8]  Oliver Trepte,et al.  Computer control for a galvanometer scanner in a confocal scanning laser microscope , 1994 .

[9]  Ikram E. Abdou Effect of signal truncation on centroid location error estimation , 1996 .

[10]  Kjell Carlsson,et al.  The influence of specimen refractive index, detector signal integration, and non‐uniform scan speed on the imaging properties in confocal microscopy , 1991 .

[11]  John G. Fryer,et al.  Estimator for the random error in subpixel target location and its use in the bundle adjustment , 1994, Other Conferences.

[12]  N. Bobroff Position measurement with a resolution and noise‐limited instrument , 1986 .

[13]  P. Volkov Noise in position measurement by centroid calculation , 1996 .

[14]  Brian F. Alexander,et al.  Elimination of systematic error in subpixel accuracy centroid estimation [also Letter 34(11)3347-3348(Nov1995)] , 1991 .