Application of Fluorescence Correlation Spectroscopy for Velocity Imaging in Microfluidic Devices

In this paper we present and demonstrate a technique for mapping fluid flow rates in microfluidic systems with sub-micrometer resolution using confocal microscopy in conjunction with fluorescence correlation spectroscopy (FCS). Flow velocities ranging from ∼50 μm/s to ∼ 10 cm/s can be recorded using fluorescent polymer nanospheres as fluid motion tracers. Velocity profiles and images of the flow in poly(dimethylsiloxane)–glass microchannels are presented and analyzed. Using the method, velocity images along the horizontal (top view) and vertical planes within a microdevice can be obtained. This is, to our knowledge, the first report of FCS for producing velocity maps. The high-resolution velocity maps can be used to characterize and optimize microdevice performance and to validate simulation efforts.

[1]  H. Rigneault,et al.  Flow Profiles and Directionality in Microcapillaries Measured by Fluorescence Correlation Spectroscopy , 2002 .

[2]  B. Mohammadi,et al.  Optimization of turn geometries for microchip electrophoresis , 2001 .

[3]  Charles S Henry,et al.  Recent progress in the development of muTAS for clinical analysis. , 2003, The Analyst.

[4]  R. Rigler,et al.  Fluorescence correlation spectroscopy of triplet states in solution: a theoretical and experimental study , 1995 .

[5]  C. Pozrikidis,et al.  Fluid Dynamics: Theory, Computation, and Numerical Simulation , 2001 .

[6]  Petra Schwille,et al.  Spatial two-photon fluorescence cross-correlation spectroscopy for controlling molecular transport in microfluidic structures. , 2002, Analytical chemistry.

[7]  P. Yager,et al.  A rapid diffusion immunoassay in a T-sensor , 2001, Nature Biotechnology.

[8]  R. Rigler,et al.  Confocal spectroscopy in microstructures. , 1997, Biophysical chemistry.

[9]  Watt W. Webb,et al.  Fluorescence correlation spectroscopy. III. Uniform translation and laminar flow , 1978 .

[10]  S. K. Griffiths,et al.  Low-dispersion turns and junctions for microchannel systems. , 2001, Analytical chemistry.

[11]  Jerker Widengren,et al.  Interactions and Kinetics of Single Molecules as Observed by Fluorescence Correlation Spectroscopy , 1993 .

[12]  C. Meinhart,et al.  Apparent fluid slip at hydrophobic microchannel walls , 2002 .

[13]  R A Mathies,et al.  Capillary electrophoresis chips with integrated electrochemical detection. , 1998, Analytical chemistry.

[14]  Griffiths,et al.  Band spreading in two-dimensional microchannel turns for electrokinetic species transport , 2000, Analytical chemistry.

[15]  P. Ronney,et al.  Flow tagging velocimetry in incompressible flow using photo-activated nonintrusive tracking of molecular motion (PHANTOMM) , 1995 .

[16]  T. Johnson,et al.  Imaging of electroosmotic flow in plastic microchannels. , 2001, Analytical chemistry.

[17]  A Manz,et al.  Chemical amplification: continuous-flow PCR on a chip. , 1998, Science.

[18]  J. Crimaldi The effect of photobleaching and velocity fluctuations on single-point LIF measurements , 1997 .

[19]  S. Wereley,et al.  PIV measurements of a microchannel flow , 1999 .

[20]  A. Visser,et al.  Detection of flowing fluorescent particles in a microcapillary using fluorescence correlation spectroscopy. , 2002, Analytical chemistry.

[21]  W. Lempert,et al.  Flow Tagging Velocimetry Using Caged Dye Photo-Activated Fluorophores , 2000 .

[22]  P. Yager,et al.  Biotechnology at low Reynolds numbers. , 1996, Biophysical journal.

[23]  R A Mathies,et al.  Turn geometry for minimizing band broadening in microfabricated capillary electrophoresis channels. , 2000, Analytical chemistry.

[24]  D. Beebe,et al.  A particle image velocimetry system for microfluidics , 1998 .

[25]  E Neumann,et al.  Fluorescence correlation spectrometry of the interaction kinetics of tetramethylrhodamin alpha-bungarotoxin with Torpedo californica acetylcholine receptor. , 1996, Biophysical chemistry.

[26]  P. Yager,et al.  Optical measurement of transverse molecular diffusion in a microchannel. , 2001, Biophysical journal.

[27]  H. Becker,et al.  Polymer microfluidic devices. , 2002, Talanta.

[28]  Richard P. Wildes,et al.  A study of structure and motion in fluidic microsystems , 1997 .

[29]  T. Kenny,et al.  Electroosmotic capillary flow with nonuniform zeta potential , 2000, Analytical Chemistry.

[30]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[31]  D. Beebe,et al.  Physics and applications of microfluidics in biology. , 2002, Annual review of biomedical engineering.

[32]  Heino,et al.  Hydrodynamic flow profiling in microchannel structures by single molecule fluorescence correlation spectroscopy , 2000, Analytical chemistry.

[33]  Brittain,et al.  Prototyping of masks, masters, and stamps/molds for soft lithography using an office printer and photographic reduction , 2000, Analytical chemistry.

[34]  R. Rigler,et al.  Conformational fluctuations in single DNA molecules. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[35]  W. Webb,et al.  Thermodynamic Fluctuations in a Reacting System-Measurement by Fluorescence Correlation Spectroscopy , 1972 .

[36]  S. Leibler,et al.  An ultrasensitive bacterial motor revealed by monitoring signaling proteins in single cells. , 2000, Science.

[37]  G. Whitesides,et al.  Using patterns in microfiche as photomasks in 10-mu m-scale microfabrication , 1999 .

[38]  Zhongping Chen,et al.  Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media. , 1997, Optics letters.

[39]  Dennis E. Koppel,et al.  Statistical accuracy in fluorescence correlation spectroscopy , 1974 .