Orthopedic medical devices: ethical questions, implant recalls and responsibility.

The hip replacement is a surgical procedure to replace the femoral head and acetabulum with prosthetic implants to improve function, increase mobility, and relieve pain caused by damage from disorders such as osteoarthritis and fractures. In recent years, we have seen several recalls of poorly functioning implant systems, most recently, the Johnson and Johnson (J&J) Articular Surface Replacement device. Product recalls are often the results of premature failure of implants requiring additional surgery to exchange the failed device. This raises many questions - technical, medical, regulatory, ethical, and legal - that ultimately put patients at risk, compromise confidence in medicine and regulatory agencies, and important relationships including those between the physician-patient and physician-industry. Where do the responsibilities lie for the patients' suffering, morbidity, and costs of removing the failed device? This article discusses the current recall of the J&J implant, the responsibilities of the manufacturer, surgeons, and the regulatory agency.

[1]  A. Rothwell,et al.  A multinational assessment of metal-on-metal bearings in hip replacement. , 2011, The Journal of bone and joint surgery. American volume.

[2]  Henrik Malchau,et al.  The John Charnley Award: Risk Factors for Cup Malpositioning: Quality Improvement Through a Joint Registry at a Tertiary Hospital , 2011, Clinical orthopaedics and related research.

[3]  M. Bhandari,et al.  The evidence-based approach in bringing new orthopaedic devices to market. , 2010, The Journal of bone and joint surgery. American volume.

[4]  H. Gill,et al.  Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours. , 2010, The Journal of bone and joint surgery. British volume.

[5]  T J Joyce,et al.  Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear. , 2010, The Journal of bone and joint surgery. British volume.

[6]  M. Wimmer,et al.  Metal-on-metal bearing surfaces. , 2009, The Journal of the American Academy of Orthopaedic Surgeons.

[7]  C. Verheyen,et al.  Poor accuracy of freehand cup positioning during total hip arthroplasty , 2007, Archives of Orthopaedic and Trauma Surgery.

[8]  J. Galante,et al.  Relationships with industry: critical for new technology or an unnecessary evil? , 2006, The Journal of bone and joint surgery. American volume.