Interferometric measurement of corneal thickness with micrometer precision.

The recently developed partial coherence laser Doppler interferometry technique was improved to measure central and peripheral corneal thickness with high precision. Corneal thickness profiles were measured on 18 eyes of health, volunteer subjects. All of these eyes were measurable at angles (between visual axis and measuring direction) ranging from 20 degrees nasal to 25 degrees temporal. At larger angles (up to 35 degrees) only part of the eyes was measurable. The thickness profiles of the 18 corneas have a nearly perfectly parabolic shape within the measured region. The precision (standard deviation) was 1.6 microns for central measurements and decreased somewhat to about 3.5 microns at measuring angles in the range of 25 to 30 degrees. No significant interobserver variability was found on 14 eyes measured by three different observers. This study indicates that the new technique is likely to be superior to currently used ultrasound and conventional optical pachymetry techniques, especially for refractive procedures.

[1]  James J Salz,et al.  Differences among ultrasonic pachymeters in measuring corneal thickness , 1987 .

[2]  G O Waring,et al.  Results of the prospective evaluation of radial keratotomy (PERK) study one year after surgery. , 1985, Ophthalmology.

[3]  C. Edmund,et al.  Some components affecting the precision of corneal thickness measurement performed by optical pachometry , 1986, Acta ophthalmologica.

[4]  F. K. Hansen,et al.  ON THE OPTICAL MEASUREMENT OF CORNEAL THICKNESS , 1971, Acta ophthalmologica.

[5]  C. Munnerlyn,et al.  Photorefractive keratectomy: A technique for laser refractive surgery , 1988, Journal of cataract and refractive surgery.

[6]  F. Hoffmann [Refractive corneal surgery]. , 1987, Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[7]  C K Hitzenberger,et al.  Mêasurement of corneal thickness by low-coherence interferometry. , 1992, Applied optics.

[8]  C K Hitzenberger,et al.  Optical measurement of the axial eye length by laser Doppler interferometry. , 1991, Investigative ophthalmology & visual science.

[9]  C K Hitzenberger,et al.  Measurement of the axial length of cataract eyes by laser Doppler interferometry. , 1993, Investigative ophthalmology & visual science.

[10]  A. Fercher,et al.  In vivo optical coherence tomography. , 1993, American journal of ophthalmology.

[11]  C. Edmund Determination of the corneal thickness profile by optical pachometry , 1987, Acta ophthalmologica.

[12]  D. Davies,et al.  Optical coherence-domain reflectometry: a new optical evaluation technique. , 1987, Optics letters.

[13]  A. Fercher,et al.  Measurement of corneal thickness by laser Doppler interferometry. , 1992, Investigative ophthalmology & visual science.

[14]  T. Olsen,et al.  ON THE OPTICAL MEASUREMENT OF CORNEAL THICKNESS , 1980, Acta ophthalmologica.

[15]  J. Fujimoto,et al.  High-speed optical coherence domain reflectometry. , 1992, Optics letters.

[16]  A. Fercher,et al.  Eye-length measurement by interferometry with partially coherent light. , 1988, Optics letters.

[17]  K. Takada,et al.  New measurement system for fault location in optical waveguide devices based on an interferometric technique. , 1987, Applied optics.

[18]  J. Fujimoto,et al.  Micron‐resolution ranging of cornea anterior chamber by optical reflectometry , 1991, Lasers in surgery and medicine.

[19]  A. Gordon,et al.  Variability of Ultrasonic Pachometry , 1990, Optometry and vision science : official publication of the American Academy of Optometry.