Modeling and simulation of a hybrid 3D silicon detector system using SILVACO and Simulink/MATLAB framework

In this paper, a system of a hybrid pixel detector has been developed. The purpose is to create a flexible and reliable model that simulates the entire system, starting from a 3D detector to a data acquisition system and processing analysis. The model flexibility is achieved by minimizing interdependencies among its entities, so they can be added or removed as needed. The implementation of the system is accomplished using SILVACO and Simulink/MATLAB. The 3D detector is simulated using SILVACO to investigate its electrical performance. It is designed such that to have a good charge collection efficiency, position resolution and reduced charge sharing effects. Simulink is used to implement the readout circuit. The front-end readout circuit includes the Charge Sensitive Amplifier (CSA) and Active Shaper. The most suitable approach and parameters for a real system are selected according to the simulation results. Additionally, practical design constraints are also included in the model.

[1]  Ivan Peric,et al.  Particle pixel detectors in high-voltage CMOS technology—New achievements , 2011 .

[2]  N. Wermes,et al.  Development and Characterization of Diamond and 3D-Silicon Pixel Detectors with ATLAS-Pixel Readout Electronics , 2008 .

[3]  R. Orava,et al.  3D simulations of 3D silicon radiation detector structures , 2006 .

[4]  S. Ramo Currents Induced by Electron Motion , 1939, Proceedings of the IRE.

[5]  A. Berry,et al.  Modeling and simulation of the entire detector system by using Matlab and Simulink , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[6]  T. Wei,et al.  Design of a Low-Noise Front-End Readout Circuit for CdZnTe Detectors , 2013 .

[7]  Jacobus Hendricus van Lint,et al.  Mechanisms of Radiation Effects in Electronic Materials (Volume 1) , 1980 .

[8]  A. Kok Signal formation and active edge studies of 3D silicon detector technology , 2011 .

[9]  D. Stoppa,et al.  Low-Noise Avalanche Photodiode in Standard 0.35-$\mu \hbox{m}$ CMOS Technology , 2008, IEEE Transactions on Electron Devices.

[10]  D. Pennicard 3D detectors for synchrotron applications , 2009 .

[11]  K. Perez Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment , 2014 .

[12]  Celeste Fleta,et al.  First double-sided 3-D detectors fabricated at CNM-IMB , 2008 .

[13]  D. Taylor Mechanisms of Radiation Effects in Electronic Materials , 1981 .

[14]  Christian Gontrand,et al.  Performance of standard and double-sided 3D-radiation detectors under the impact of a temperature pulse , 2015 .

[15]  S. Nenonen,et al.  3D Medipix - a new generation of X-ray detectors , 2004, IEEE Symposium Conference Record Nuclear Science 2004..