In vivo time‐resolved quantitative motion mapping of the murine myocardium with phase contrast MRI

Myocardial motion of healthy mice and mice with myocardial infarction was assessed in vivo by phase contrast (PC) cine MRI. The imaging module was a segmented fast low angle shot (FLASH) sequence with velocity compensation in all three gradient directions. To accomplish additional motion encoding, the spin phase was prepared using bipolar gradient pulses, which resulted in a linear dependence between the voxel velocity and spin phase. This method provided accurate quantification of the velocity magnitude and direction of the murine myocardium at a spatial resolution of 234 μm and a temporal resolution of about 10 ms. The acquisition was EKG‐gated and the mice were anesthetized by inhalation of 1.5–4.0 vol.% isoflurane at 1.5 l/min oxygen flow. To validate the MRI measurements, an experiment with a calibrated rotating phantom was performed. Deviations between MR velocity measurements and optical assessment by a light detector were lower than 1.6%. During our study, myocardial motion velocities between 0.4 cm/s and 1.7 cm/s were determined for the healthy murine myocardium across the heart cycle. Areas with myocardial infarction were clearly segmented and showed a motion velocity which was significantly reduced. In conclusion, the method is an accurate technique for the assessment of murine myocardial motion in vivo. Magn Reson Med 49:315–321, 2003. © 2003 Wiley‐Liss, Inc.

[1]  P. R. Moran A flow velocity zeugmatographic interlace for NMR imaging in humans. , 1982, Magnetic resonance imaging.

[2]  D. Firmin,et al.  Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique , 1984, Journal of computer assisted tomography.

[3]  Michael Markl,et al.  Cardiac phase contrast gradient echo MRI: measurement of myocardial wall motion in healthy volunteers and patients , 1999, The International Journal of Cardiac Imaging.

[4]  C. Higgins,et al.  Functional evaluation of the heart with magnetic resonance imaging , 1988, Magnetic resonance in medicine.

[5]  D N Firmin,et al.  Blood flow imaging by cine magnetic resonance. , 1986, Journal of computer assisted tomography.

[6]  S J Riederer,et al.  Compensation for effects of linear motion in MR imaging , 1989, Magnetic resonance in medicine.

[7]  H. W. Korin,et al.  Adaptive motion compensation in MRI: Accuracy of motion measurement , 1991, Magnetic resonance in medicine.

[8]  James S. Duncan,et al.  Toward reliable, noninvasive measurement of myocardial function from 4D images , 1994, Medical Imaging.

[9]  A. Haase,et al.  FLASH imaging: rapid NMR imaging using low flip-angle pulses. 1986. , 1986, Journal of magnetic resonance.

[10]  A. Crawley,et al.  Elimination of oblique flow artifacts in magnetic resonance imaging , 1992, Magnetic resonance in medicine.

[11]  V. Wedeen Magnetic resonance imaging of myocardial kinematics. technique to detect, localize, and quantify the strain rates of the active human myocardium , 1992, Magnetic resonance in medicine.

[12]  D N Firmin,et al.  In vivo validation of MR velocity imaging. , 1987, Journal of computer assisted tomography.

[13]  L. Axel,et al.  Heart wall motion: improved method of spatial modulation of magnetization for MR imaging. , 1989, Radiology.

[14]  C. Lorenz,et al.  Left ventricular torsion is equal in mice and humans. , 2000, American journal of physiology. Heart and circulatory physiology.

[15]  Stuart S Berr,et al.  MR tagging early after myocardial infarction in mice demonstrates contractile dysfunction in adjacent and remote regions , 2002, Magnetic resonance in medicine.

[16]  R. Balaban,et al.  Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial ischemia , 1999, Magnetic resonance in medicine.

[17]  D. Noll,et al.  Tracking of cyclic motion with phase‐contrast cine MR velocity data , 1995, Journal of magnetic resonance imaging : JMRI.

[18]  G. Glover,et al.  Encoding strategies for three‐direction phase‐contrast MR imaging of flow , 1991, Journal of magnetic resonance imaging : JMRI.

[19]  D G Nishimura,et al.  On the nature and reduction of the displacement artifact in flow images , 1991, Magnetic resonance in medicine.

[20]  E. Zerhouni,et al.  Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion. , 1988, Radiology.

[21]  Stefan Neubauer,et al.  Magnetic resonance microimaging for noninvasive quantification of myocardial function and mass in the mouse , 1998, Magnetic resonance in medicine.

[22]  Mark A. Griswold,et al.  NMR probeheads for In Vivo applications , 2000 .

[23]  P. V. van Dijk Direct cardiac NMR imaging of heart wall and blood flow velocity. , 1984, Journal of computer assisted tomography.

[24]  E M Haacke,et al.  Improving MR image quality in the presence of motion by using rephasing gradients. , 1987, AJR. American journal of roentgenology.

[25]  R. Herfkens,et al.  Evaluation of Myocardial Motion Tracking With Cine-Phase Contrast Magnetic Resonance Imaging , 1994, Investigative radiology.

[26]  L Axel,et al.  MR flow imaging by velocity-compensated/uncompensated difference images. , 1987, Journal of computer assisted tomography.

[27]  L Söndergaard,et al.  Pulse sequence design for MR velocity mapping of complex flow: notes on the necessity of low echo times. , 1994, Magnetic resonance imaging.

[28]  N J Pelc,et al.  A rapid-gated cine MRI technique. , 1988, Magnetic resonance annual.