A risk model for enteric virus accumulation and release from recycled water distribution pipe biofilms

Screening-level quantitative microbial risk assessments (QMRA) undertaken to assess health risks associated with the reticulation of recycled water have identified distribution pipe biofilms and their ability to accumulate enteric and opportunistic pathogens as potential sources of public health concern. A simplistic model to assess human health risks associated with enteric virions (extracellular viruses) present in recycled water for domestic use was therefore developed. Recycled water biofilms formed on glass and stainless steel coupons in a laboratory-scale distribution system were challenged with model enteric virions (B40-8, MS-2 and FX174 bacteriophages). Approximately 1 % of bacteriophages present in the adjacent bulk water was incorporated into 3 month-old biofilms and a persistent sub-population (0.01 %) of the model enteric virions remained infectious in biofilms throughout an experimental period of 30 days. Significant potential for virions to accumulate within biofilms was therefore demonstrated, and indeed biofilm uptake could mask treatment failures assessed through analysis of the bulk water (infectious virions would not be detected after 1.5 km even if 10.L -1 virions present in treated effluent). Subsequent sloughing of biofilm into the bulk water phase could therefore release infective virions within mobilized aggregates of biofilm and infect susceptible consumers. During normal operating conditions (one virion in 100 L of water) sufficient virions may accumulate within distribution pipe biofilms that a 50% sloughing event could present a P i (annual) of 1.9×10 -4 for the consumption of 1 mL of water, exceeding the US-EPA benchmark of 10 -4 .

[1]  F. Smith,et al.  COLORIMETRIC METHOD FOR DETER-MINATION OF SUGAR AND RELATED SUBSTANCE , 1956 .

[2]  B. Olson,et al.  Microbiology of potable water. , 1984, Advances in applied microbiology.

[3]  E. Geldreich,et al.  A new medium for the enumeration and subculture of bacteria from potable water , 1985, Applied and environmental microbiology.

[4]  R. Wagner,et al.  The Bacteriophages , 1988, The Viruses.

[5]  Charles P. Gerba,et al.  Modeling the Risk from Giardia and Viruses in Drinking Water , 1991 .

[6]  C N Haas,et al.  Risk assessment of virus in drinking water. , 1993, Risk analysis : an official publication of the Society for Risk Analysis.

[7]  J. Laîné,et al.  Mechanism of Cryptosporidium, Giardia, and MS2 virus removal by MF and UF , 1995 .

[8]  Joan B. Rose,et al.  Removal of pathogenic and indicator microorganisms by a full-scale water reclamation facility , 1996 .

[9]  Charles P. Gerba,et al.  Waterborne rotavirus: A risk assessment , 1996 .

[10]  C N Haas,et al.  Sensitive populations: who is at the greatest risk? , 1996, International journal of food microbiology.

[11]  L. Kiene,et al.  Virus behaviour within a distribution system , 1997 .

[12]  L. Kiene,et al.  Poliovirus-1 inactivation and interaction with biofilm: a pilot-scale study , 1997, Applied and environmental microbiology.

[13]  P. Payment,et al.  Poor efficacy of residual chlorine disinfectant in drinking water to inactivate waterborne pathogens in distribution systems. , 1999, Canadian journal of microbiology.

[14]  J. Rose,et al.  Quantitative Microbial Risk Assessment , 1999 .

[15]  R. Desjardins,et al.  LIVE/DEAD BacLight : application of a new rapid staining method for direct enumeration of viable and total bacteria in drinking water. , 1999, Journal of microbiological methods.

[16]  A H Havelaar,et al.  The Beta Poisson Dose‐Response Model Is Not a Single‐Hit Model , 2000, Risk analysis : an official publication of the Society for Risk Analysis.

[17]  K. Schleifer,et al.  Microbiological safety of drinking water. , 2000, Annual review of microbiology.

[18]  M V Storey,et al.  Persistence of two model enteric viruses (B40-8 and MS-2 bacteriophages) in water distribution pipe biofilms. , 2001, Water science and technology : a journal of the International Association on Water Pollution Research.

[19]  P. Teunis,et al.  Modeling Virus Inactivation on Salad Crops Using Microbial Count Data , 2001, Risk analysis : an official publication of the Society for Risk Analysis.

[20]  M. Storey,et al.  A comparison of methods and models for the analysis of water distribution pipe biofilms , 2002 .

[21]  Frank Stagnitti,et al.  Quantitative microbial risk assessment modelling for the use of reclaimed water in irrigated horticulture , 2005 .