Abstract Introduction: Technologies such as microscopy have pushed surgeons to the limits of their dexterity and endurance. Robotic advances such as tremor filtration and motion scaling permit maximal use of magnification, and enable precise, tremor-free tool manipulation during microsurgery. To our knowledge, however, no such device exists for image-guided, ambidextrous microneurosurgery, prompting us to develop our own system. Methods: We approached a company with exceptional experience in space robotics to design and construct an appropriate system. A systematic and structured approached was followed for the design of neuroArm. Engineers studied the operating room environment with the assistance of surgeons and nursing staff. A preliminary design was developed, and subsequently evaluated by surgical staff. Selected materials were tested at 3.0 T to ensure MR compatibility and performance characteristics of the robot actuators and encoders were evaluated. Results: We have developed an MR compatible ambidextrous robot capable of both microneurosurgery and stereotaxy. The design is based on a SCARA configuration and has 8-DOF (including tool actuation). The end-effector is designed to interface with standard neurosurgical tools and is equipped with a 3-DOF optical force sensor for haptic feedback. Comprehensive testing of materials was conducted in a 3-T magnet to ensure compatibility. Breadboard testing results suggest a tool tip resolution of 30 μm. Discussion: A systematic approach has been applied to the development of a unique and dexterous neurosurgical robot. The system promises to enhance surgical performance, reduce fatigue, and improve surgical outcomes. This seamless integration of robotics with iMRI will further revolutionize neurosurgery.
[1]
D. Louw,et al.
A mobile high-field magnetic resonance system for neurosurgery.
,
1999,
Journal of neurosurgery.
[2]
J M Rubin,et al.
History of intraoperative ultrasound in neurosurgery.
,
2001,
Neurosurgery clinics of North America.
[3]
W. Boyd,et al.
3-D image guidance for minimally invasive robotic coronary artery bypass.
,
2000,
The heart surgery forum.
[4]
C J Henri,et al.
Multimodality image integration for stereotactic surgical planning.
,
1991,
Medical physics.
[5]
G R Sutherland,et al.
Neurosurgical suite of the future. III.
,
2001,
Neuroimaging clinics of North America.
[6]
N. Hopf,et al.
Basic principles and clinical applications of neuronavigation and intraoperative computed tomography.
,
1998,
Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[7]
T. Peters.
Image-guided surgery: From X-rays to Virtual Reality
,
2001,
Computer methods in biomechanics and biomedical engineering.
[8]
R. Kikinis,et al.
Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications.
,
1997,
Neurosurgery.