Improved single phase SRF algorithm for CHB inverter based shunt active power filter under non-ideal supply conditions

This paper presents five-level cascaded H-bridge multilevel inverter based shunt active power filter for medium voltage and high power distribution system. An improved single-phase synchronous reference frame theory based control algorithm is proposed in this paper for solving current related power quality problems. This control is well capable of improving power factor and maintaining better voltage regulation in the distribution sector. This proposed control is a complete solution in case of balanced and/or unbalanced loading condition in existing distribution system. This control algorithm is equally effective in case of distorted and/or unbalanced supply voltage condition. The proposed system is designed in Simulink platform of MATLAB software. The effectiveness of the proposed algorithm is tested in different possible conditions. Test results suggest its effectiveness over conventional control algorithms.

[1]  Chih‐Chiang Hua,et al.  A shunt active power filter adopting Lyapunov control approach , 2010 .

[2]  Y. Y. Chen,et al.  Placement of power quality monitors using enhanced genetic algorithm and wavelet transform , 2011 .

[3]  P. K. Dash,et al.  Power Quality Disturbance Data Compression, Detection, and Classification Using Integrated Spline Wavelet and S-Transform , 2002, IEEE Power Engineering Review.

[4]  Mahesh K. Mishra,et al.  Improved hysteresis current control of three-level inverter for distribution static compensator application , 2009 .

[5]  A. Teke,et al.  A Novel Reference Signal Generation Method for Power-Quality Improvement of Unified Power-Quality Conditioner , 2011, IEEE Transactions on Power Delivery.

[6]  Birendra Biswal,et al.  Automatic Classification of Power Quality Events Using Balanced Neural Tree , 2014, IEEE Transactions on Industrial Electronics.

[7]  Bhim Singh,et al.  Better Control for a Solar Energy System: Using Improved Enhanced Phase-Locked Loop-Based Control Under Variable Solar Intensity , 2017, IEEE Industry Applications Magazine.

[8]  P. Garcia-Gonzalez,et al.  Application of a Repetitive Controller for a Three-Phase Active Power Filter , 2007, IEEE Transactions on Power Electronics.

[9]  Soumyadeep Ray,et al.  A Comprehensive Review on Cascaded H-bridge Inverter-Based Large-Scale Grid-Connected Photovoltaic , 2017 .

[10]  Kamalakanta Mahapatra,et al.  A novel control strategy of DSTATCOM for load compensation under distorted utility condition , 2014, 2014 International Conference on Advances in Electrical Engineering (ICAEE).

[11]  Bhim Singh,et al.  Simple peak detection control algorithm of distribution static compensator for power quality improvement , 2014 .

[12]  Aruna Ranaweera Power Factor Correction and Harmonic Control , 1998 .

[13]  Om Prakash Mahela,et al.  Topological aspects of power quality improvement techniques: A comprehensive overview , 2016 .

[14]  B. Chatterjee,et al.  Rough-Set-Based Feature Selection and Classification for Power Quality Sensing Device Employing Correlation Techniques , 2013, IEEE Sensors Journal.

[15]  K. Al-Haddad,et al.  Power factor correction and zero voltage regulation in distribution system using DSTATCOM , 2012, 2012 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES).

[16]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[17]  Om Prakash Mahela,et al.  A critical review of detection and classification of power quality events , 2015 .

[18]  Ramon Costa-Castelló,et al.  Power factor correction and harmonic compensation using second-order odd-harmonic repetitive control , 2012 .

[19]  Anup Kumar Panda,et al.  Simulation and real-time implementation of shunt active filter i d -i q control strategy for mitigation of harmonics with different fuzzy membership functions , 2012 .