A novel MALDI LIFT-TOF/TOF mass spectrometer for proteomics

A new matrix-assisted laser-desorption/ionization time-of-flight/time-of-flight mass spectrometer with the novel "LIFT" technique (MALDI LIFT-TOF/TOF MS) is described. This instrument provides high sensitivity (attomole range) for peptide mass fingerprints (PMF). It is also possible to analyze fragment ions generated by any one of three different modes of dissociation: laser-induced dissociation (LID) and high-energy collision-induced dissociation (CID) as real MS/MS techniques and in-source decay in the reflector mode of the mass analyzer (reISD) as a pseudo-MS/MS technique. Fully automated operation including spot picking from 2D gels, in-gel digestion, sample preparation on MALDI plates with hydrophilic/hydrophobic spot profiles and spectrum acquisition/processing lead to an identification rate of 66% after the PMF was obtained. The workflow control software subsequently triggered automated acquisition of multiple MS/MS spectra. This information, combined with the PMF increased the identification rate to 77%, thus providing data that allowed protein modifications and sequence errors in the protein sequence database to be detected. The quality of the MS/MS data allowed for automated de novo sequencing and protein identification based on homology searching.

[1]  A. Sickmann,et al.  Identification of post‐translationally modified proteins in proteome studies , 2001, Electrophoresis.

[2]  T. Rudel,et al.  Analysis of missed cleavage sites, tryptophan oxidation and N-terminal pyroglutamylation after in-gel tryptic digestion. , 2000, Rapid communications in mass spectrometry : RCM.

[3]  Jennifer M. Campbell,et al.  The characteristics of peptide collision-induced dissociation using a high-performance MALDI-TOF/TOF tandem mass spectrometer. , 2000, Analytical chemistry.

[4]  K. Biemann Appendix 5. Nomenclature for peptide fragment ions (positive ions). , 1990, Methods in enzymology.

[5]  D. Kirsch,et al.  Sequenching of peptides in a time-of-flight mass spectrometer: evaluation of postsource decay following matrix-assisted laser desorption ionisation (MALDI) , 1994 .

[6]  K. Gevaert,et al.  Protein identification methods in proteomics , 2000, Electrophoresis.

[7]  D. Garozzo,et al.  Sequencing of oligosaccharides by collision-induced dissociation matrix-assisted laser desorption/ionization mass spectrometry. , 2000, Journal of mass spectrometry : JMS.

[8]  Jennifer M. Campbell,et al.  Matrix‐assisted laser desorption/ionization‐tandem mass spectrometry with high resolution and sensitivity for identification and characterization of proteins , 2002, Proteomics.

[9]  Timothy B. Stockwell,et al.  The Sequence of the Human Genome , 2001, Science.

[10]  S. Gygi,et al.  Quantitative proteomic analysis using a MALDI quadrupole time-of-flight mass spectrometer. , 2001, Analytical chemistry.

[11]  R. S. Brown,et al.  Identifying proteins using matrix-assisted laser desorption/ionization in-source fragmentation data combined with database searching. , 1998, Analytical chemistry.

[12]  Andy Brass,et al.  A RAPID algorithm for sequence database comparisons: application to the identification of vector contamination in the EMBL databases , 1999, Bioinform..

[13]  I. Mclaren,et al.  TIME-OF-FLIGHT MASS SPECTROMETER WITH IMPROVED RESOLUTION , 1955 .

[14]  C. Enke,et al.  An interleaved comb ion deflection gate for m/z selection in time‐of‐flight mass spectrometry , 1996 .

[15]  R. Cramer,et al.  The nature of collision-induced dissociation processes of doubly protonated peptides: comparative study for the future use of matrix-assisted laser desorption/ionization on a hybrid quadrupole time-of-flight mass spectrometer in proteomics. , 2001, Rapid communications in mass spectrometry : RCM.

[16]  K. Gevaert,et al.  Protein identification based on matrix assisted laser desorption/ionization‐post source decay‐mass spectrometry , 2001, Electrophoresis.

[17]  A. Purcell,et al.  The use of post-source decay in matrix-assisted laser desorption/ionisation mass spectrometry to delineate T cell determinants. , 2001, Journal of immunological methods.

[18]  I. Papayannopoulos,et al.  The interpretation of collision‐induced dissociation tandem mass spectra of peptides , 1996 .

[19]  Peer Bork,et al.  More than 1,000 putative new human signalling proteins revealed by EST data mining , 2000, Nature Genetics.

[20]  S. Weinberger,et al.  Unknown peptide sequencing using matrix-assisted laser desorption/ionization and in-source decay. , 1998, Analytical chemistry.

[21]  E. Nordhoff,et al.  Prestructured MALDI-MS sample supports. , 2000, Analytical chemistry.

[22]  P. Bork,et al.  Charting the proteomes of organisms with unsequenced genomes by MALDI-quadrupole time-of-flight mass spectrometry and BLAST homology searching. , 2001, Analytical chemistry.

[23]  S. Gygi,et al.  Development of a multiplexed microcapillary liquid chromatography system for high-throughput proteome analysis. , 2002, Analytical chemistry.

[24]  S. Gygi,et al.  Correlation between Protein and mRNA Abundance in Yeast , 1999, Molecular and Cellular Biology.

[25]  Stephen A. Martin,et al.  Identification of the facile gas-phase cleavage of the Asp-Pro and Asp-Xxx peptide bonds in matrix-assisted laser desorption time-of-flight mass spectrometry. , 1993, Analytical chemistry.

[26]  D. Suckau,et al.  MALDI-PSD-MS analysis of the phosphorylation sites of caseinomacropeptide , 2001, Peptides.

[27]  E. Nordhoff,et al.  Alpha-cyano-4-hydroxycinnamic acid affinity sample preparation. A protocol for MALDI-MS peptide analysis in proteomics. , 2001, Analytical chemistry.

[28]  M. Mann,et al.  Proteomics to study genes and genomes , 2000, Nature.

[29]  D. Suckau,et al.  Screening for disulfide bonds in proteins by MALDI in-source decay and LIFT-TOF/TOF-MS. , 2002, Analytical chemistry.

[30]  Joachim Klose,et al.  Two‐dimensional electrophoresis of proteins: An updated protocol and implications for a functional analysis of the genome , 1995, Electrophoresis.

[31]  J. V. Moran,et al.  Initial sequencing and analysis of the human genome. , 2001, Nature.

[32]  K. Gevaert,et al.  Sample preparation procedures for ultrasensitive protein identification by PSD-MALDI-TOF mass spectrometry. , 1998, Journal of protein chemistry.