Investigation on thermal performance of steel heat exchanger for ground source heat pump systems using full-scale experiments and numerical simulations

In this manuscript, we investigated thermal performance for a new type of ground heat exchanger (GHE) with higher thermal conductivity materials of steel by using both methods of full-scale experimental tests (pipes buried underground with a depth of 100 m) and computational fluid dynamics (CFD) simulation. Thermal performance was based on the temperature differences between inlet and outlet of U-tubes and the heat transfer per unit borehole depth (QL). In addition, we also analyzed the entire thermal resistance of the borehole and the surrounding soil as well as the soil temperature distribution around the heat exchanger U-tubes. We found the further apart from the U-tubes, the smaller the soil temperature. Due to smaller heat resistance magnitude, the GHE performance of steel pipe was always better compared to conventional PE types, with QL increased up to 36%. Moreover, different inlet mass flow rates were also taken into consideration, and we found QL was always increasing with the increase of inlet velocities. The designed distance of GHE borehole was recommended to be larger than at least 1.4 m for steel pipe system and 1.2 m for PE one when the system is operated in continuous periods or intermittent operation of 8 h. Finally, cost analysis for both steel systems and the PE ones were discussed. This study will further facilitate for the future application of steel GHE for Ground Source Heat Pump systems.

[1]  Louis Lamarche,et al.  A new contribution to the finite line-source model for geothermal boreholes , 2007 .

[2]  Georgios A. Florides,et al.  Ground heat exchangers—A review of systems, models and applications , 2007 .

[3]  C. K. Lee,et al.  Computer simulation of borehole ground heat exchangers for geothermal heat pump systems , 2008 .

[4]  Yanzhong Li,et al.  Numerical investigation on thermal performance of ground heat exchangers using phase change materials as grout for ground source heat pump system , 2016 .

[5]  Yelin Deng,et al.  Experimental and numerical study on the thermal performance of ground source heat pump with a set of designed buried pipes , 2017 .

[6]  Gianpiero Colangelo,et al.  CFD simulations of horizontal ground heat exchangers: A comparison among different configurations , 2012 .

[7]  Baizhan Li,et al.  Simulation and experimental analysis of optimal buried depth of the vertical U-tube ground heat exchanger for a ground-coupled heat pump system , 2015 .

[8]  Benamar Bouhacina,et al.  Numerical investigation of a novel tube design for the geothermal borehole heat exchanger , 2015 .

[9]  Enshen Long,et al.  Numerical simulation of ground heat exchangers based on dynamic thermal boundary conditions in solid zone , 2013 .

[10]  Yuehong Lu,et al.  A simplified analytical model to evaluate the impact of radiant heat on building cooling load , 2015 .

[11]  T. Kiatsiriroat,et al.  Enhancement of fin efficiency of a solid wire fin by oscillating heat pipe under forced convection , 2014 .

[12]  Viorel Badescu,et al.  Simple and accurate model for the ground heat exchanger of a passive house , 2007 .

[13]  Ye Tianzhen,et al.  Numerical and experimental investigation of a helical coil heat exchanger for seawater-source heat pump in cold region , 2016 .

[14]  M. Santamouris,et al.  On the performance of buildings coupled with earth to air heat exchangers , 1995 .

[15]  Xiaozhou Wu,et al.  Research of heat and moisture transfer influence on the characteristics of the ground heat pump exchangers in unsaturated soil , 2016 .

[16]  Nasir Hayat,et al.  CFD applications in various heat exchangers design: A review , 2012 .

[17]  Yu Xiaohui,et al.  Thermal response test for ground source heat pump based on constant temperature and heat-flux methods , 2016 .

[18]  Zhang Lin,et al.  Experimental analysis on a novel frost-free air-source heat pump water heater system , 2014 .

[19]  Helen Theodoropoulou,et al.  Public awareness and willingness to adopt ground source heat pumps for domestic heating and cooling , 2014 .

[20]  Joseph Khedari,et al.  Field study using the ground as a heat sink for the condensing unit of an air conditioner in Thailand , 2001 .

[21]  Ye Tianzhen,et al.  The thermal performance of seawater-source heat pump systems in areas of severe cold during winter , 2015 .

[22]  Sufen Li,et al.  Analysis of geo-temperature recovery under intermittent operation of ground-source heat pump , 2011 .

[23]  I. V. Shevchuk,et al.  Numerical Study of Convective Heat Transfer Enhancement in a Pipe Rotating Around a Parallel Axis , 2014 .

[24]  Keishi Kariya,et al.  Numerical study of horizontal ground heat exchangers for design optimization , 2016 .

[25]  Michele De Carli,et al.  Thermal performance of two types of energy foundation pile: Helical pipe and triple U-tube , 2013 .

[26]  Yan Shang,et al.  Analysis on the transient heat transfer process inside and outside the borehole for a vertical U-tube ground heat exchanger under short-term heat storage , 2016 .

[27]  Xiaosong Zhang,et al.  Soil temperature distribution around a U-tube heat exchanger in a multi-function ground source heat pump system , 2009 .