New trends in fast liquid chromatography for food and environmental analysis.

There is an increasing need for applications in food and environmental areas able to cope with a large number of analytes in very complex matrices. The new analytical procedures demand sensitivity, robustness and high resolution within an acceptable analysis time. The purpose of this review is to describe new trends based on fast liquid chromatography applied to the food and environmental analysis. It includes different column technologies, such as monolithic, sub-2 μm, porous shell, as well as different stationary phases such as reversed phase (C8 and C18), hydrophilic interaction liquid chromatography (HILIC) and fluorinated columns. Additionally, recent sample extraction and clean-up methodologies applied to reduce sample manipulation and total analysis time in food and environmental analysis--QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), on line solid phase extraction coupled to ultrahigh pressure liquid chromatography (on line SPE-UHPLC), turbulent flow chromatography (TFC) and molecularly imprinted polymers (MIPs), were also addressed. The advantages and drawbacks of these methodologies applied to the fast and sensitive analyses of food and environmental samples are going to be discussed.

[1]  S. Yao,et al.  Simultaneous determination of melamine and related compounds by hydrophilic interaction liquid chromatography-electrospray mass spectrometry. , 2010, Journal of separation science.

[2]  W. Yong,et al.  Simultaneous determination of 15 steroidal oral contraceptives in water using solid-phase disk extraction followed by high performance liquid chromatography-tandem mass spectrometry. , 2009, Journal of chromatography. A.

[3]  P. Solich,et al.  Determination of fluoroquinolone antibiotics in surface waters from Mondego River by high performance liquid chromatography using a monolithic column. , 2007, Journal of separation science.

[4]  S. Heinisch,et al.  Sense and nonsense of high-temperature liquid chromatography. , 2009, Journal of chromatography. A.

[5]  S. Lehotay,et al.  Rapid sample preparation method for LC-MS/MS or GC-MS analysis of acrylamide in various food matrices. , 2006, Journal of agricultural and food chemistry.

[6]  P. Lucci,et al.  Molecularly imprinted polymer solid-phase extraction for detection of zearalenone in cereal sample extracts. , 2010, Analytica chimica acta.

[7]  G. Guiochon,et al.  Comparison of heat friction effects in narrow-bore columns packed with core–shell and totally porous particles , 2010 .

[8]  H. Nakazawa,et al.  Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[9]  C. Poole,et al.  Insights into the Retention Mechanism on a Pentafluorophenylpropylsiloxane-Bonded Silica Stationary Phase (Discovery HS F5) in RP-LC , 2006 .

[10]  F. Oz Quantitation of heterocyclic aromatic amines in ready to eat meatballs by ultra fast liquid chromatography. , 2011, Food chemistry.

[11]  Damià Barceló,et al.  Fully automated determination of 74 pharmaceuticals in environmental and waste waters by online solid phase extraction-liquid chromatography-electrospray-tandem mass spectrometry. , 2010, Talanta.

[12]  G. Guiochon,et al.  Comparison between the efficiencies of columns packed with fully and partially porous C18-bonded silica materials. , 2007, Journal of chromatography. A.

[13]  Huiming Wu,et al.  Simultaneous determination of seven neonicotinoid pesticide residues in food by ultraperformance liquid chromatography tandem mass spectrometry. , 2010, Journal of agricultural and food chemistry.

[14]  J. Ritchie,et al.  A fast and simple assay for busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry using turbulent flow online extraction technology. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[15]  M. Balogh,et al.  Ultra performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry for high-sensitivity and high-throughput analysis of U.S. Environmental Protection Agency 16 priority pollutants polynuclear aromatic hydrocarbons. , 2009, Analytical chemistry.

[16]  J. Haginaka,et al.  Molecularly imprinted polymers for triazine herbicides prepared by multi-step swelling and polymerization method. Their application to the determination of methylthiotriazine herbicides in river water. , 2007, Journal of chromatography. A.

[17]  P. Mottier,et al.  Quantitative high-throughput analysis of 16 (fluoro)quinolones in honey using automated extraction by turbulent flow chromatography coupled to liquid chromatography-tandem mass spectrometry. , 2008, Journal of agricultural and food chemistry.

[18]  H. Luo,et al.  Simultaneous Determination of Cimaterol, Salbutamol, Terbutaline and Ractopamine in Feed by SPE Coupled to UPLC , 2011 .

[19]  Yan Li,et al.  Determination of triclosan, triclocarban and methyl-triclosan in aqueous samples by dispersive liquid-liquid microextraction combined with rapid liquid chromatography. , 2009, Journal of chromatography. A.

[20]  R. Carabias-Martínez,et al.  Use of a bisphenol-A imprinted polymer as a selective sorbent for the determination of phenols and phenoxyacids in honey by liquid chromatography with diode array and tandem mass spectrometric detection. , 2009, Analytica chimica acta.

[21]  P. Cao,et al.  A multi-residue method for fast determination of pesticides in tea by ultra performance liquid chromatography–electrospray tandem mass spectrometry combined with modified QuEChERS sample preparation procedure , 2011 .

[22]  S. Goscinny,et al.  Rapid analysis of melamine residue in milk, milk products, bakery goods and flour by ultra-performance liquid chromatography/tandem mass spectrometry: From food crisis to accreditation , 2011 .

[23]  Amadeo R. Fernández-Alba,et al.  Accurate-mass databases for comprehensive screening of pesticide residues in food by fast liquid chromatography time-of-flight mass spectrometry. , 2009, Analytical chemistry.

[24]  J. Jorgenson,et al.  Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns. , 1997, Analytical chemistry.

[25]  M. Galceran,et al.  Analysis of UV ink photoinitiators in packaged food by fast liquid chromatography at sub-ambient temperature coupled to tandem mass spectrometry. , 2011, Journal of Chromatography A.

[26]  Guang-yu Liu,et al.  Characteristic of theophylline imprinted monolithic column and its application for determination of xanthine derivatives caffeine and theophylline in green tea. , 2006, Journal of chromatography. A.

[27]  L. Colón,et al.  Fused-core, sub-2 microm packings, and monolithic HPLC columns: a comparative evaluation. , 2009, Journal of separation science.

[28]  X. Qiao,et al.  The biomimetic immunoassay based on molecularly imprinted polymer: a comprehensive review of recent progress and future prospects. , 2011, Journal of food science.

[29]  Ruijin Liu,et al.  Magnetic molecularly imprinted polymer beads prepared by microwave heating for selective enrichment of β-agonists in pork and pig liver samples. , 2011, Talanta.

[30]  Wen Jiang,et al.  Determination of melamine in milk powder using zwitterionic HILIC stationary phase with UV detection. , 2010, Journal of separation science.

[31]  T. Nakahara,et al.  Liquid chromatography/mass spectrometric determination of patulin in apple juice using atmospheric pressure photoionization. , 2003, Rapid communications in mass spectrometry : RCM.

[32]  Zhiyuan Dai,et al.  Multi-walled carbon nanotubes as solid-phase extraction adsorbent for the ultra-fast determination of chloramphenicol in egg, honey, and milk by fused-core C18-based high-performance liquid chromatography–tandem mass spectrometry , 2010, Analytical and bioanalytical chemistry.

[33]  V. Sharma,et al.  Development and validation of a method for determination of corticosteroids in pig fat using liquid chromatography-tandem mass spectrometry. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[34]  W. Lambert,et al.  Validation of a solid-phase extraction and liquid chromatography-electrospray tandem mass spectrometric method for the determination of nine basic pharmaceuticals in wastewater and surface water samples. , 2008, Journal of chromatography. A.

[35]  M. Marazuela,et al.  A review of novel strategies of sample preparation for the determination of antibacterial residues in foodstuffs using liquid chromatography-based analytical methods. , 2009, Analytica chimica acta.

[36]  F. Gosetti,et al.  Determination of perfluorochemicals in biological, environmental and food samples by an automated on-line solid phase extraction ultra high performance liquid chromatography tandem mass spectrometry method. , 2010, Journal of chromatography. A.

[37]  Yingping Huang,et al.  Development and validation of a hydrophilic interaction liquid chromatographic method for determination of aromatic amines in environmental water. , 2010, Journal of chromatography. A.

[38]  Qiang Fu,et al.  Matrine-imprinted monolithic stationary phase for extraction and purification of matrine from Sophorae flavescentis Ait. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[39]  G. Guiochon,et al.  Performance of columns packed with the new shell particles, Kinetex-C18. , 2010, Journal of chromatography. A.

[40]  J. V. Sancho,et al.  Quantification, confirmation and screening capability of UHPLC coupled to triple quadrupole and hybrid quadrupole time-of-flight mass spectrometry in pesticide residue analysis. , 2010, Journal of mass spectrometry : JMS.

[41]  G. Guiochon,et al.  Performance of columns packed with the new shell Kinetex-C18 particles in gradient elution chromatography. , 2010, Journal of chromatography. A.

[42]  J. Hajšlová,et al.  Novel approaches in analysis of Fusarium mycotoxins in cereals employing ultra performance liquid chromatography coupled with high resolution mass spectrometry. , 2010, Analytica chimica acta.

[43]  Félix Hernández,et al.  Multi-class determination of around 50 pharmaceuticals, including 26 antibiotics, in environmental and wastewater samples by ultra-high performance liquid chromatography-tandem mass spectrometry. , 2011, Journal of chromatography. A.

[44]  Jian Wang,et al.  Applications of LC/ESI-MS/MS and UHPLC QqTOF MS for the determination of 148 pesticides in fruits and vegetables , 2010, Analytical and bioanalytical chemistry.

[45]  X. Xia,et al.  Simultaneous Determination of Fluoroquinolones, Tetracyclines and Sulfonamides in Chicken Muscle by UPLC–MS–MS , 2010 .

[46]  P. Lucci,et al.  Solid-phase extraction using molecularly imprinted polymer for selective extraction of natural and synthetic estrogens from aqueous samples. , 2011, Journal of chromatography. A.

[47]  A. Martín‐Esteban,et al.  Selective high performance liquid chromatography imprinted-stationary phases for the screening of phenylurea herbicides in vegetable samples. , 2005, Journal of chromatography. A.

[48]  P. He,et al.  Temperature effect on peak width and column efficiency in subcritical water chromatography. , 2002, Journal of chromatographic science.

[49]  Xiao-bai Xu,et al.  Temperature-controlled ionic liquid dispersive liquid phase microextraction combined with ultra-high-pressure liquid chromatography for the rapid determination of triclosan, triclocarban and methyl-triclosan in aqueous samples , 2010 .

[50]  P. Liu,et al.  Turbulent-flow chromatography coupled on-line to fast high-performance liquid chromatography and mass spectrometry for simultaneous determination of verticine, verticinone and isoverticine in rat plasma. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[51]  Sadao Arai,et al.  Synthesis of monodispersed molecularly imprinted polymer particles for high-performance liquid chromatographic separation of cholesterol using templating polymerization in porous silica gel bound with cholesterol molecules on its surface. , 2010, Journal of chromatography. A.

[52]  D. Meany,et al.  An automated turbulent flow liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method for quantitation of serum creatinine. , 2010, Clinica chimica acta; international journal of clinical chemistry.

[53]  Miss A.O. Penney (b) , 1974, The New Yale Book of Quotations.

[54]  K. Nakanishi,et al.  Preparation of monolithic silica columns for high-performance liquid chromatography. , 2008, Journal of chromatography. A.

[55]  Katerina Mastovska,et al.  Pesticide multiresidue analysis in cereal grains using modified QuEChERS method combined with automated direct sample introduction GC-TOFMS and UPLC-MS/MS techniques. , 2010, Journal of agricultural and food chemistry.

[56]  Zeng-hong Xie,et al.  A molecularly imprinted monolith for the fast chiral separation of antiparasitic drugs by pressurized CEC. , 2010, Journal of separation science.

[57]  M. Galceran,et al.  Analysis of amprolium by hydrophilic interaction liquid chromatography-tandem mass spectrometry. , 2010, Journal of chromatography. A.

[58]  Surong Mei,et al.  Preparation of high selective molecularly imprinted polymers for tetracycline by precipitation polymerization , 2007 .

[59]  G. Guiochon,et al.  Unusual behavior of the height equivalent to a theoretical plate of a new poroshell stationary phase at high temperatures. , 2007, Journal of chromatography. A.

[60]  K. Rentsch,et al.  Development of a fully automated toxicological LC-MSn screening system in urine using online extraction with turbulent flow chromatography , 2011, Analytical and bioanalytical chemistry.

[61]  Zhaosheng Liu,et al.  Molecularly imprinted polymers as a tool for separation in CEC , 2007, Electrophoresis.

[62]  M. Nielen,et al.  Identification of anabolic steroids and derivatives using bioassay-guided fractionation, UHPLC/TOFMS analysis and accurate mass database searching. , 2010, Analytica chimica acta.

[63]  John R Engen,et al.  High-speed and high-resolution UPLC separation at zero degrees Celsius. , 2008, Analytical chemistry.

[64]  H. Neels,et al.  Analysis of drugs of abuse in wastewater by hydrophilic interaction liquid chromatography–tandem mass spectrometry , 2009, Analytical and bioanalytical chemistry.

[65]  M. Galceran,et al.  On-line solid phase extraction fast liquid chromatography-tandem mass spectrometry for the analysis of bisphenol A and its chlorinated derivatives in water samples. , 2010, Journal of chromatography. A.

[66]  F. Gosetti,et al.  A new hydrophilic interaction liquid chromatography tandem mass spectrometry method for the simultaneous determination of seven biogenic amines in cheese. , 2008, Journal of chromatography. A.

[67]  Xiaoyan Liu,et al.  A novel molecularly imprinted polymer for simultaneous extraction and determination of sudan dyes by on-line solid phase extraction and high performance liquid chromatography. , 2010, Journal of chromatography. A.

[68]  K. Nakanishi,et al.  Octadecylsilylated porous silica rods as separation media for reversed-phase liquid chromatography. , 1996, Analytical chemistry.

[69]  J. Veuthey,et al.  Fast analysis in liquid chromatography using small particle size and high pressure. , 2006, Journal of separation science.

[70]  T. Ikegami,et al.  Separation efficiencies in hydrophilic interaction chromatography. , 2008, Journal of chromatography. A.

[71]  M. Sawyer,et al.  Column-switching reversed phase-hydrophilic interaction liquid chromatography/tandem mass spectrometry method for determination of free estrogens and their conjugates in river water. , 2008, Analytica chimica acta.

[72]  Hong Zhang,et al.  Determination of marker residue of Olaquindox in fish tissue by ultra performance liquid chromatography-tandem mass spectrometry. , 2011, Journal of separation science.

[73]  M. Palma,et al.  Fast analysis of soy isoflavones by high-performance liquid chromatography with monolithic columns. , 2007, Analytica chimica acta.

[74]  M. Bernart,et al.  Reversed-phase high-performance liquid chromatographic method using a pentafluorophenyl bonded phase for analysis of tocopherols , 1994 .

[75]  M. Galceran,et al.  Fast liquid chromatography/tandem mass spectrometry (highly selective selected reaction monitoring) for the determination of toltrazuril and its metabolites in food , 2010, Analytical and bioanalytical chemistry.

[76]  Xingzhong Zhao,et al.  Selective sample pretreatment by molecularly imprinted polymer monolith for the analysis of fluoroquinolones from milk samples. , 2010, Journal of chromatography. A.

[77]  S. Benvenuti,et al.  Fast high-performance liquid chromatography analysis of phenethylamine alkaloids in Citrus natural products on a pentafluorophenylpropyl stationary phase. , 2007, Journal of chromatography. A.

[78]  Zhenxia Du,et al.  Rapid and simultaneous determination of amoxicillin, penicillin G, and their major metabolites in bovine milk by ultra-high-performance liquid chromatography-tandem mass spectrometry. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[79]  A. Covaci,et al.  Application of hydrophilic interaction chromatography for the analysis of polar contaminants in food and environmental samples. , 2011, Journal of chromatography. A.

[80]  P. Solich,et al.  Development and application of UHPLC-MS/MS method for the determination of phenolic compounds in Chamomile flowers and Chamomile tea extracts. , 2010, Talanta.

[81]  C. Horváth,et al.  Micro Beads Coated with a Porous Thin Layer as Column Packing in Gas Chromatography. Some Properties of Graphitized Carbon Black as the Stationary Phase. , 1964 .

[82]  R. Krebber,et al.  Simple and rapid determination of enrofloxacin and ciprofloxacin in edible tissues by turbulent flow chromatography/tandem mass spectrometry (TFC-MS/MS). , 2009, Analytica chimica acta.

[83]  M. Biesaga,et al.  Analysis of phenolic acids in fruits by HPLC with monolithic columns. , 2007, Journal of separation science.

[84]  N. Leepipatpiboon,et al.  Efficient hydrophilic interaction liquid chromatography-tandem mass spectrometry for the multiclass analysis of veterinary drugs in chicken muscle. , 2010, Analytica chimica acta.

[85]  H. Neels,et al.  Analysis of cocaine and its principal metabolites in waste and surface water using solid-phase extraction and liquid chromatography–ion trap tandem mass spectrometry , 2008, Analytical and bioanalytical chemistry.

[86]  M. Galceran,et al.  Preventing false negatives with high-resolution mass spectrometry: the benzophenone case. , 2011, Rapid communications in mass spectrometry : RCM.

[87]  A. Alpert Hydrophilic-interaction chromatography for the separation of peptides, nucleic acids and other polar compounds. , 1990, Journal of chromatography.

[88]  G. McMillin,et al.  A rapid and fully-automated method for the quantitation of tricyclic antidepressants in serum using turbulent-flow liquid chromatography-tandem mass spectrometry. , 2010, Clinica chimica acta; international journal of clinical chemistry.

[89]  R. Markovich,et al.  Comparison study of porous, fused-core, and monolithic silica-based C18 HPLC columns for Celestoderm-V Ointment analysis. , 2009, Journal of pharmaceutical and biomedical analysis.

[90]  R. Romero-González,et al.  Determination of aflatoxins B1, B2, G1, G2 and ochratoxin A in animal feed by ultra high-performance liquid chromatography-tandem mass spectrometry. , 2010, Journal of separation science.

[91]  Steven J Lehotay,et al.  Fast and easy multiresidue method employing acetonitrile extraction/partitioning and "dispersive solid-phase extraction" for the determination of pesticide residues in produce. , 2003, Journal of AOAC International.

[92]  R. Niessner,et al.  Selective trace analysis of diclofenac in surface and wastewater samples using solid-phase extraction with a new molecularly imprinted polymer. , 2008, Analytica chimica acta.

[93]  M. Lee,et al.  Practical aspects of ultrahigh pressure capillary liquid chromatography. , 2001, Journal of chromatography. A.

[94]  M. Ibáñez,et al.  Determination of mycotoxins in different food commodities by ultra-high-pressure liquid chromatography coupled to triple quadrupole mass spectrometry. , 2009, Rapid communications in mass spectrometry : RCM.

[95]  K. Shimizu,et al.  Molecularly imprinted polymer sensor arrays. , 2010, Current opinion in chemical biology.

[96]  R. Muñiz-Valencia,et al.  A liquid chromatography method using a monolithic column for the determination of corticoids in animal feed and animal feeding water , 2008, Analytical and bioanalytical chemistry.

[97]  M. Galceran,et al.  Liquid chromatography/tandem mass spectrometry (highly selective selected reaction monitoring) for the analysis of isopropylthioxanthone in packaged food. , 2008, Journal of chromatography. A.

[98]  Brian Kinsella,et al.  Current trends in sample preparation for growth promoter and veterinary drug residue analysis. , 2009, Journal of chromatography. A.

[99]  S. Bover-Cid,et al.  Validation of an ultra high pressure liquid chromatographic method for the determination of biologically active amines in food. , 2009, Journal of chromatography. A.

[100]  J. P. Pavón,et al.  Simplified QuEChERS approach for the extraction of chlorinated compounds from soil samples. , 2010, Talanta.

[101]  Xiwen He,et al.  Determination of tetracyclines in food samples by molecularly imprinted monolithic column coupling with high performance liquid chromatography. , 2009, Talanta.

[102]  J. V. Sancho,et al.  Application of ultra-high-pressure liquid chromatography-tandem mass spectrometry to the determination of multi-class pesticides in environmental and wastewater samples. Study of matrix effects. , 2009, Journal of chromatography. A.

[103]  M. Galceran,et al.  Analysis of bisphenols in soft drinks by on-line solid phase extraction fast liquid chromatography-tandem mass spectrometry. , 2011, Analytica chimica acta.

[104]  Zhiyuan Dai,et al.  Simultaneous determination of NOGE-related and BADGE-related compounds in canned food by ultra-performance liquid chromatography–tandem mass spectrometry , 2010, Analytical and bioanalytical chemistry.

[105]  Seung Mi Lee,et al.  Open tubular capillary columns with basic templates made by the generalized preparation protocol in capillary electrochromatography chiral separation and template structural effects on chiral separation capability. , 2011, Journal of chromatography. A.

[106]  J. Guiteras,et al.  Development and validation of a multiclass method for the analysis of antibiotic residues in eggs by liquid chromatography-tandem mass spectrometry. , 2011, Journal of chromatography. A.

[107]  M. Galceran,et al.  Analysis of chlormequat and mepiquat by hydrophilic interaction chromatography coupled to tandem mass spectrometry in food samples. , 2009, Journal of chromatography. A.

[108]  E. Simó-Alfonso,et al.  Fast separation and determination of sterols in vegetable oils by ultraperformance liquid chromatography with atmospheric pressure chemical ionization mass spectrometry detection. , 2010, Journal of Agricultural and Food Chemistry.

[109]  B. Shao,et al.  Development of a Rapid LC–MS–MS Method for Multi-Class Determination of 14 Coccidiostat Residues in Eggs and Chicken , 2009 .

[110]  M. Biesaga,et al.  Fast analysis of prominent flavonoids in tomato using a monolithic column and isocratic HPLC. , 2009, Journal of separation science.

[111]  G. Stubbings,et al.  The development and validation of a multiclass liquid chromatography tandem mass spectrometry (LC-MS/MS) procedure for the determination of veterinary drug residues in animal tissue using a QuEChERS (QUick, Easy, CHeap, Effective, Rugged and Safe) approach. , 2009, Analytica chimica acta.

[112]  Huang-Hao Yang,et al.  Molecularly imprinted polymer for selective extraction of domoic acid from seafood coupled with high-performance liquid chromatographic determination. , 2011, Talanta.

[113]  E. Turiel,et al.  Molecularly imprinted capillary electrochromatography for selective determination of thiabendazole in citrus samples. , 2008, Journal of chromatography. A.

[114]  J. Hollender,et al.  Challenge of high polarity and low concentrations in analysis of cytostatics and metabolites in wastewater by hydrophilic interaction chromatography/tandem mass spectrometry. , 2009, Journal of chromatography. A.

[115]  F. Borrull,et al.  Stir-bar-sorptive extraction and ultra-high-performance liquid chromatography–tandem mass spectrometry for simultaneous analysis of UV filters and antimicrobial agents in water samples , 2010, Analytical and bioanalytical chemistry.

[116]  J. Giddings Comparison of Theoretical Limit of Separating Speed in Gas and Liquid Chromatography. , 1965 .

[117]  Damià Barceló,et al.  Application of fully automated online solid phase extraction-liquid chromatography-electrospray-tandem mass spectrometry for the determination of sulfonamides and their acetylated metabolites in groundwater , 2011, Analytical and bioanalytical chemistry.

[118]  Bahruddin Saad,et al.  A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry. , 2010, Analytica chimica acta.

[119]  W. Lambert,et al.  Comparison of matrix effects in HPLC-MS/MS and UPLC-MS/MS analysis of nine basic pharmaceuticals in surface waters , 2008, Journal of the American Society for Mass Spectrometry.

[120]  B. Paull,et al.  Dual gradient LC method for the determination of pharmaceutical residues in environmental samples using a monolithic silica reversed phase column , 2006 .

[121]  Davy Guillarme,et al.  High throughput qualitative analysis of polyphenols in tea samples by ultra-high pressure liquid chromatography coupled to UV and mass spectrometry detectors. , 2010, Journal of chromatography. A.

[122]  Xingang Liu,et al.  Rapid residue analysis of four triazolopyrimidine herbicides in soil, water, and wheat by ultra-performance liquid chromatography coupled to tandem mass spectrometry , 2011, Analytical and bioanalytical chemistry.

[123]  M. Doreau,et al.  Simultaneous quantification of carotenoids, retinol, and tocopherols in forages, bovine plasma, and milk: validation of a novel UPLC method , 2010, Analytical and bioanalytical chemistry.

[124]  B. Paull,et al.  Improved method for the determination of zinc pyrithione in environmental water samples incorporating on-line extraction and preconcentration coupled with liquid chromatography atmospheric pressure chemical ionisation mass spectrometry. , 2006, Journal of chromatography. A.

[125]  T. Teutenberg Potential of high temperature liquid chromatography for the improvement of separation efficiency--a review. , 2009, Analytica chimica acta.

[126]  C. Domeño,et al.  Determination of bile acids in human serum by on-line restricted access material-ultra high-performance liquid chromatography-mass spectrometry. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[127]  Elena Lizarraga,et al.  Validation of a UHPLC-FLD method for the simultaneous quantification of aflatoxins, ochratoxin A and zearalenone in barley , 2011 .

[128]  A. Napoli,et al.  High-throughput assay of oleopentanedialdheydes in extra virgin olive oil by the UHPLC-ESI-MS/MS and isotope dilution methods. , 2011, Analytical chemistry.

[129]  J. J. Salisbury,et al.  Fused-core particles: a practical alternative to sub-2 micron particles. , 2008, Journal of chromatographic science.

[130]  M. Galceran,et al.  Liquid chromatography multi-stage mass spectrometry for the analysis of 5-hydroxymethylfurfural in foods. , 2008, Journal of chromatography. A.

[131]  Knut Irgum,et al.  Hydrophilic interaction chromatography. , 2006, Journal of separation science.

[132]  Yen Wah Tong,et al.  Molecularly imprinted beads by surface imprinting , 2007, Analytical and bioanalytical chemistry.

[133]  O. Endo,et al.  Simultaneous Determination of Medicinal Ingredients in So-called Health-promoting Food Using Liquid Chromatography Tandem Mass Spectrometry with a Pentafluorophenyl Stationary Phase , 2009 .

[134]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[135]  I. Wilson,et al.  Application of turbulent flow chromatography to the metabonomic analysis of human plasma: comparison with protein precipitation. , 2010, Journal of separation science.

[136]  D. Shangguan,et al.  Monolithic molecularly imprinted polymer for sulfamethoxazole and molecular recognition properties in aqueous mobile phase. , 2006, Analytica chimica acta.

[137]  Li-ren Chen,et al.  Simultaneous determination of sex hormones in egg products by ZnCl2 depositing lipid, solid-phase extraction and ultra performance liquid chromatography/electrospray ionization tandem mass spectrometry. , 2010, Analytica chimica acta.

[138]  Wei Yan,et al.  Molecularly imprinted solid-phase extraction for the selective determination of 17beta-estradiol in fishery samples with high performance liquid chromatography. , 2009, Talanta.

[139]  G. Guiochon,et al.  The mass transfer kinetics in columns packed with Halo-ES shell particles. , 2011, Journal of chromatography. A.

[140]  Sarah De Saeger,et al.  Multimycotoxin UPLC-MS/MS for tea, herbal infusions and the derived drinkable products. , 2010, Journal of agricultural and food chemistry.

[141]  M. Ibáñez,et al.  UHPLC–MS/MS highly sensitive determination of aflatoxins, the aflatoxin metabolite M1 and ochratoxin A in baby food and milk , 2011 .

[142]  Jian Wang,et al.  Applications of ultra-performance liquid chromatography electrospray ionization quadrupole time-of-flight mass spectrometry on analysis of 138 pesticides in fruit- and vegetable-based infant foods. , 2009, Journal of agricultural and food chemistry.

[143]  A. García-Lafuente,et al.  Fast and simultaneous determination of phenolic compounds and caffeine in teas, mate, instant coffee, soft drink and energetic drink by high-performance liquid chromatography using a fused-core column. , 2011, Analytica chimica acta.

[144]  C. Delerue-Matos,et al.  Analysis of polycyclic aromatic hydrocarbons in fish: evaluation of a quick, easy, cheap, effective, rugged, and safe extraction method. , 2009, Journal of separation science.

[145]  A. Furey,et al.  Determination of anthelmintic drug residues in milk using ultra high performance liquid chromatography-tandem mass spectrometry with rapid polarity switching. , 2010, Journal of chromatography. A.

[146]  D. Treutter,et al.  Optimization of a high-performance liquid chromatography method for the analysis of complex polyphenol mixtures and application for sainfoin extracts (Onobrychis viciifolia). , 2010, Journal of chromatography. A.

[147]  M. Koupparis,et al.  Comparison of performance of C18 monolithic rod columns and conventional C18 particle-packed columns in liquid chromatographic determination of Estrogel and Ketoprofen gel. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[148]  Zhiyuan Dai,et al.  Development of an on-line matrix solid-phase dispersion/fast liquid chromatography/tandem mass spectrometry system for the rapid and simultaneous determination of 13 sulfonamides in grass carp tissues. , 2011, Journal of chromatography. A.

[149]  E. Turiel,et al.  Molecularly imprinted polymers: an analytical tool for the determination of benzimidazole compounds in water samples. , 2009, Talanta.

[150]  Damià Barceló,et al.  Comparative study of an estradiol enzyme-linked immunosorbent assay kit, liquid chromatography-tandem mass spectrometry, and ultra performance liquid chromatography-quadrupole time of flight mass spectrometry for part-per-trillion analysis of estrogens in water samples. , 2007, Journal of chromatography. A.

[151]  Y. Hsieh,et al.  Fused-core silica column high-performance liquid chromatography/tandem mass spectrometric determination of rimonabant in mouse plasma. , 2007, Analytical chemistry.

[152]  T. Langlois,et al.  Characteristics of superficially-porous silica particles for fast HPLC: some performance comparisons with sub-2-microm particles. , 2008, Journal of chromatographic science.

[153]  Richard O'Kennedy,et al.  Benzimidazole carbamate residues in milk: Detection by Surface Plasmon Resonance-biosensor, using a modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method for extraction. , 2009, Analytica chimica acta.

[154]  Milena Zachariasova,et al.  Analysis of multiple mycotoxins in cereals under ambient conditions using direct analysis in real time (DART) ionization coupled to high resolution mass spectrometry. , 2010, Talanta.

[155]  Thomas P. Mechtler,et al.  The application of multiplexed, multi-dimensional ultra-high-performance liquid chromatography/tandem mass spectrometry to the high-throughput screening of lysosomal storage disorders in newborn dried bloodspots. , 2010, Rapid communications in mass spectrometry : RCM.

[156]  Yan Peng,et al.  Selective molecularly imprinted stationary phases for bisphenol A analysis prepared by modified precipitation polymerization. , 2009, Journal of separation science.

[157]  G. Guiochon,et al.  Mass transfer mechanism in liquid chromatography columns packed with shell particles: would there be an optimum shell structure? , 2010, Journal of chromatography. A.

[158]  C. Gagnon,et al.  Application of Turbulent Flow Chromatography Load Columns for the On-Line Analysis of Anti-Infectives in Wastewaters , 2009 .

[159]  Jae-Min Lim,et al.  Determination of trace bisphenol A in complex samples using selective molecularly imprinted solid-phase extraction coupled with capillary electrophoresis , 2011 .

[160]  X. Xia,et al.  Validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for determination of ractopamine: Application to residue depletion study in swine , 2011 .

[161]  J. Knox Practical Aspects of LC Theory , 1977 .

[162]  L. Nováková,et al.  A review of current trends and advances in modern bio-analytical methods: chromatography and sample preparation. , 2009, Analytica chimica acta.

[163]  M. Galceran,et al.  Fast liquid chromatography-tandem mass spectrometry for the analysis of bisphenol A-diglycidyl ether, bisphenol F-diglycidyl ether and their derivatives in canned food and beverages. , 2011, Journal of chromatography. A.

[164]  D. Sherrington,et al.  Chromatographic comparison of bupivacaine imprinted polymers prepared in crushed monolith, microsphere, silica-based composite and capillary monolith formats. , 2007, Journal of chromatography. A.

[165]  F. Liu,et al.  Application of molecularly imprinted polymers to solid-phase extraction of analytes from real samples. , 2007, Journal of biochemical and biophysical methods.

[166]  R. Hale,et al.  Parameters for ultra-performance liquid chromatographic/tandem mass spectrometric analysis of selected androgens versus estrogens in aqueous matrices. , 2009, Analytical chemistry.

[167]  J. Fekete,et al.  Comparative study of new shell-type, sub-2 micron fully porous and monolith stationary phases, focusing on mass-transfer resistance. , 2010, Journal of chromatography. A.

[168]  Takanobu Takihara,et al.  Uniformly-sized, molecularly imprinted polymers for (-)-epigallocatechin gallate, -epicatechin gallate and -gallocatechin gallate by multi-step swelling and polymerization method. , 2007, Journal of chromatography. A.

[169]  A. Turner,et al.  Molecularly imprinted sorbent assays: recent developments and applications. , 2009, Chemistry.

[170]  J. Fekete,et al.  Efficiency of the new sub-2 μm core-shell (Kinetex™) column in practice, applied for small and large molecule separation. , 2011, Journal of pharmaceutical and biomedical analysis.

[171]  E. Turiel,et al.  Molecularly imprinted polymers for solid-phase extraction and solid-phase microextraction: recent developments and future trends. , 2007, Journal of chromatography. A.

[172]  Marek Biziuk,et al.  Determination of pesticide residues in food matrices using the QuEChERS methodology , 2011 .

[173]  K. Tran,et al.  Determination of polycyclic aromatic hydrocarbons (PAHs) in shrimp. , 2010, Journal of agricultural and food chemistry.

[174]  R. Romero-González,et al.  Simultaneous determination of pesticides, biopesticides and mycotoxins in organic products applying a quick, easy, cheap, effective, rugged and safe extraction procedure and ultra-high performance liquid chromatography-tandem mass spectrometry. , 2011, Journal of chromatography. A.

[175]  Maria Careri,et al.  Particle-packed column versus silica-based monolithic column for liquid chromatography-electrospray-linear ion trap-tandem mass spectrometry multiallergen trace analysis in foods. , 2010, Journal of chromatography. A.

[176]  Yongjiang Wu,et al.  Simultaneous determination of 10 mycotoxins in grain by ultra-high-performance liquid chromatography–tandem mass spectrometry using 13C15-deoxynivalenol as internal standard , 2010, Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment.

[177]  Andrew G. Mayes,et al.  COMPARATIVE STUDY OF IMPRINTED POLYMER PARTICLES PREPARED BY DIFFERENT POLYMERISATION METHODS , 2004 .

[178]  S. Fanali,et al.  Fast-liquid chromatography using columns of different internal diameters packed with sub-2 μm silica particles. , 2012, Journal of chromatography. A.

[179]  V. Pichon,et al.  Solid-phase extraction using molecularly imprinted polymers for selective extraction of a mycotoxin in cereals. , 2010, Journal of chromatography. A.

[180]  Georges Guiochon,et al.  Monolithic columns in high-performance liquid chromatography. , 2007, Journal of chromatography. A.

[181]  W. Dungchai,et al.  Rapid separation and highly sensitive detection methodology for sulfonamides in shrimp using a monolithic column coupled with BDD amperometric detection. , 2009, Talanta.

[182]  H. Mayer,et al.  A new ultra-pressure liquid chromatography method for the determination of biogenic amines in cheese. , 2010, Journal of chromatography. A.

[183]  H. Nohta,et al.  Determination of polar organophosphorus pesticides in water samples by hydrophilic interaction liquid chromatography with tandem mass spectrometry. , 2008, Rapid communications in mass spectrometry : RCM.

[184]  Marilena E. Dasenaki,et al.  Multi-residue determination of seventeen sulfonamides and five tetracyclines in fish tissue using a multi-stage LC-ESI-MS/MS approach based on advanced mass spectrometric techniques. , 2010, Analytica chimica acta.