Integrated Flexible Hybrid Silicone-Textile Dual-Resonant Sensors and Switching Circuit for Wearable Neurodegeneration Monitoring Systems

This paper describes the design, development, and testing of flexible hybrid silicone-textile sensors and a flexible switching circuit that were integrated into a wearable system for monitoring neurodegenerative diseases. A total of 6 planar monopole antenna sensors were fabricated that propagates at two separate resonant frequencies: 800 MHz and 2.1 GHz respectively. In addition, 2 switching circuits, each having 3 switches and 4 SMA breakout boards, were assembled and placed on the wearable neurodegeneration monitoring system. Each switching circuit connects 3 sensors to a single port on a vector network analyzer (VNA) that is used to generate and receive microwave signals. Experiments were performed using the wearable device with the developed sensors and switching circuit on phantoms mimicking two common physiological changes in the brain caused by neurodegenerative diseases: 1) brain atrophy and 2) lateral ventricle enlargement. The dual nature of the sensors’ resonance allows it to detect both brain atrophy and lateral ventricle enlargement separately at different operating frequency. This provides the advantage of minimizing the number of sensor elements needed to monitor neurodegenerative disease. The use of a switching circuit also allows for quick and convenient measurements by choosing which sensors are active for ports 1 and 2 on the VNA respectively. In addition to being low-cost, the flexibility of the materials used in fabrication allows the sensors and switching circuit to be conformal to the patient's head. Results from the experiments indicates that the sensors and switching circuit were working successfully when integrated into the wearable device.

[1]  Nick C Fox,et al.  Whole-brain atrophy rate in Alzheimer disease , 2008, Neurology.

[2]  M. Eliasziw,et al.  Comparison of MRI and CT for detection of acute intracerebral hemorrhage. , 2005, JAMA.

[3]  Andreas Fhager,et al.  Microwave technology for detecting traumatic intracranial bleedings: tests on phantom of subdural hematoma and numerical simulations , 2016, Medical & Biological Engineering & Computing.

[4]  A. M. Abbosh,et al.  On-site Rapid Diagnosis of Intracranial Hematoma using Portable Multi-slice Microwave Imaging System , 2016, Scientific Reports.

[5]  Tughrul Arslan,et al.  Flexible antenna array for wearable head imaging system , 2017, 2017 11th European Conference on Antennas and Propagation (EUCAP).

[6]  Eini Niskanen,et al.  Whole brain atrophy rate predicts progression from MCI to Alzheimer’s disease , 2010, Neurobiology of Aging.

[7]  Leena Ukkonen,et al.  Polydimethylsiloxane-Embedded Conductive Fabric: Characterization and Application for Realization of Robust Passive and Active Flexible Wearable Antennas , 2018, IEEE Access.

[8]  M. Luby,et al.  Comparison of MRI and CT for detection of acute intracerebral hemorrhage. , 2004, JAMA.

[9]  Amin M. Abbosh,et al.  Microwave System to Detect Traumatic Brain Injuries Using Compact Unidirectional Antenna and Wideband Transceiver With Verification on Realistic Head Phantom , 2014, IEEE Transactions on Microwave Theory and Techniques.

[10]  Tughrul Arslan,et al.  Wearable device for microwave head imaging , 2016, 2016 46th European Microwave Conference (EuMC).

[11]  Tughrul Arslan,et al.  Noninvasive Wearable RF Device Towards Monitoring Brain Atrophy and Lateral Ventricle Enlargement , 2020, IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology.

[12]  Sharon E. Lee,et al.  Cerebral Ventricular Changes Associated With Transitions Between Normal Cognitive Function, Mild Cognitive Impairment, and Dementia , 2007, Alzheimer disease and associated disorders.

[13]  Amin M. Abbosh,et al.  Wearable Electromagnetic Head Imaging System Using Flexible Wideband Antenna Array Based on Polymer Technology for Brain Stroke Diagnosis , 2019, IEEE Transactions on Biomedical Circuits and Systems.

[14]  G. A. E. Vandenbosch,et al.  A smart wearable textile array system for biomedical telemetry applications , 2013, IEEE Transactions on Microwave Theory and Techniques.

[15]  E. Pancera,et al.  UWB synthetic aperture-based radar system for hemorrhagic head-stroke detection , 2011, 2011 IEEE RadarCon (RADAR).

[16]  R. Bartha,et al.  Ventricular enlargement as a possible measure of Alzheimer's disease progression validated using the Alzheimer's disease neuroimaging initiative database. , 2008, Brain : a journal of neurology.

[17]  Tughrul Arslan,et al.  A Low Cost and Compact RF Switching System for Wearable Microwave Head Imaging with Performance Verification on Artificial Head Phantom , 2018 .

[18]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[19]  Amin M. Abbosh,et al.  Microwave System for Head Imaging , 2014, IEEE Transactions on Instrumentation and Measurement.