Control of a Fault-Tolerant Photovoltaic Energy Converter in Island Operation

The paper deals with design and control of a fault tolerant and reconfigurable photovoltaic converter integrating a Battery Energy Storage System as a standby backup energy resource. When a failure occurs, an appropriate control method makes the energy conversion system capable of operating in open-delta configuration in parallel with the grid as well as in islanded mode. In case network voltage is lacking due to heavy anomalies or maintenance reasons, the proposed control system is able to quickly disconnect the inverter from the grid while ensuring the energy continuity to the local load and the emergency fixtures by means of the integrated battery packs. In particular, the paper proposes a fast islanding detection method essential for the correct operation of the control system. This specific technique is based on the Hilbert transform of the voltage of the point of common coupling, and it identifies the utility lack in a period of time equal to half a grid cycle in the best case (i.e., 10 ms), thus resulting in good speed performance fully meeting the standard requirements. A thorough numerical investigation is carried out with reference to a representative case study in order to demonstrate the feasibility and the effectiveness of the proposed control strategy.

[1]  Javad Olamaei,et al.  Islanding Detection of Distributed Generation Based on Parallel Inductive Impedance Switching , 2020, IEEE Systems Journal.

[2]  Venkata R. Reddy,et al.  A Feedback-Based Passive Islanding Detection Technique for One-Cycle-Controlled Single-Phase Inverter Used in Photovoltaic Systems , 2020, IEEE Transactions on Industrial Electronics.

[3]  Javad Sadeh,et al.  Maximum Power Point Tracking Injection Method for Islanding Detection of Grid-Connected Photovoltaic Systems in Microgrid , 2021, IEEE Transactions on Power Delivery.

[4]  M. Coppola,et al.  Design and control of an advanced PV inverter , 2014 .

[5]  Teymoor Ghanbari,et al.  Passive islanding detection scheme based on autocorrelation function of modal current envelope for photovoltaic units , 2017 .

[6]  Leopoldo G. Franquelo,et al.  Grid-Connected Photovoltaic Systems: An Overview of Recent Research and Emerging PV Converter Technology , 2015, IEEE Industrial Electronics Magazine.

[7]  Enrique Romero-Cadaval,et al.  Grid-Connected Photovoltaic Plants: An Alternative Energy Source, Replacing Conventional Sources , 2015, IEEE Industrial Electronics Magazine.

[8]  Nasrudin Abd Rahim,et al.  A review of the islanding detection methods in grid-connected PV inverters , 2013 .

[9]  Chung-Yuen Won,et al.  Comprehensive Review of Islanding Detection Methods for Distributed Generation Systems , 2019, Energies.

[10]  Diego Iannuzzi,et al.  PV Module-Level CHB Inverter with Integrated Battery Energy Storage System , 2019, Energies.

[11]  Ehab F. El-Saadany,et al.  Impact of DG interface control on islanding detection and nondetection zones , 2006 .

[12]  Mikihiko Matsui,et al.  A review of current anti-islanding methods for photovoltaic power system , 2010 .

[13]  M. Veerachary,et al.  Reliability Issues in Photovoltaic Power Processing Systems , 2008, IEEE Transactions on Industrial Electronics.

[14]  Giorgio Spiazzi,et al.  Small-signal analysis of DC-DC converters with sliding mode control , 1997 .

[15]  Pierluigi Siano,et al.  An Effective Passive Islanding Detection Algorithm for Distributed Generations , 2019, Energies.

[16]  M. Liserre,et al.  Future Energy Systems: Integrating Renewable Energy Sources into the Smart Power Grid Through Industrial Electronics , 2010, IEEE Industrial Electronics Magazine.

[17]  Enrique Romero-Cadaval,et al.  Grid-Connected Photovoltaic Generation Plants: Components and Operation , 2013, IEEE Industrial Electronics Magazine.