Assessment of voltage quality indicators in unbalanced and harmonic distorted regime

This paper deals with the development of a model for assessment of the indicators, which characterize the unbalanced and harmonic distorted operation regime in the three-phase low voltage networks. The symmetrical components transformation and the Fourier method are applied, in which each harmonic is decomposed into zero, positive and negative sequence components. The quality indicators in voltage distorted and unbalanced regime are obtained using MathCAD software. The proposed model and procedure is applied for specific case studies. This approach allows the identification and analysis of distorted and unbalanced regime indicators of three-phase low voltage supply system in common coupling point of the consumer, and the procedure can be integrated into a power quality monitoring system.

[1]  Sarath Perera,et al.  Sources of Error in Unbalance Measurements , 2002 .

[2]  A.E. Emanuel,et al.  Summary of IEEE standard 1459: definitions for the measurement of electric power quantities under sinusoidal, nonsinusoidal, balanced, or unbalanced conditions , 2004, IEEE Transactions on Industry Applications.

[3]  B. Banerjee,et al.  Assessment of Voltage Unbalance , 2001, IEEE Power Engineering Review.

[4]  Elena Helerea,et al.  Software application for unbalanced regime analysis in three phase low voltage networks , 2013 .

[5]  Z. Olczykowski,et al.  Methods of voltage unbalance estimation in electric power networks , 2006 .

[6]  A. Liew Excessive neutral currents in three-phase fluorescent lighting circuits , 1989 .

[7]  Gerald T. Heydt,et al.  On the use of RMS values in power quality assessment , 2003 .

[8]  Róbert Istók MEASUREMENT SYSTEMS FOR HIGH FREQUENCY NOISE EMISSION OF COMPACT FLUORESCENT LAMPS , 2013 .

[9]  A. Testa,et al.  Harmonic and interharmonic distortion in current source type inverter drives , 1995 .

[10]  Diogo C. Garcia,et al.  Voltage unbalance numerical evaluation and minimization , 2009 .

[11]  Michal Pokorny Analysis of Unbalance Due to Asymmetrical Loads , 2005 .

[12]  P. Postolache,et al.  Analysis of Three-Phase Systems With Neutral Under Distorted and Unbalanced Conditions in the Symmetrical Component-Based Framework , 2007, IEEE Transactions on Power Delivery.

[13]  A. Dell'Aquila,et al.  New power-quality assessment criteria for supply systems under unbalanced and nonsinusoidal conditions , 2004, IEEE Transactions on Power Delivery.

[14]  P. Postolache,et al.  Experimental Evaluation of Unbalance and Distortion Indicators in Three-Phase Systems with Neutral , 2007, 2007 IEEE Lausanne Power Tech.

[15]  José Carlos de Oliveira,et al.  The sharing of responsibility between the supplier and the consumer for harmonic voltage distortion : A case study , 2008 .

[16]  Math Bollen IEEE Richard Harold Kaufmann Award Call for Nominations , 2002 .

[17]  A. A. Girgis,et al.  Evaluating Power System Unbalance in the Presence of Harmonic Distortion , 2002, IEEE Power Engineering Review.

[18]  Dan Apetrei,et al.  Power quality monitoring. Data relevance and usefulness , 2010, Melecon 2010 - 2010 15th IEEE Mediterranean Electrotechnical Conference.

[19]  Angelo Baggini,et al.  Handbook of Power Quality , 2008 .